Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Malaysia: 1800 88 3496
International+65 6415 5353

RTD In-Head Temperature Transmitter

TX12

RTD PT100 Temperature Transmitters | TX12

RTD PT100 Temperature Transmitters

SGD177.60 TX12

CE
  • User Trim—Null Out Sensor Error
  • Unique Push Button Configuration Without PC
  • High Stability
  • Programmable Burnout
  • LED Sensor Fail Indicator
  • Reconfigure in Seconds
Temperature Transmitters - View related products

Description

The TX12 head mounted temperature transmitter connects to any standard pt100 resistance sensor and converts the linearized temperature to a 4 to 20 mA signal. The transmitter is a two wire device, and is fully configurable by the user, over a wide temperature range, with the aid of a simple push button. This new TX12 design incorporates additional configuration menus, allowing the user to push button trim the transmitter output at both zero and span, ideal for trimming out sensor errors. The transmitters advanced circuitry guaranties high stability over the wide operating ambient temperature ranges experienced by head mounted devices. One of the transmitters features is the program LED, which provides visual indication of sensor fault when in normal operation and is also used to guide the operator through the simple menus during configuration.

SPECIFICATIONS
Input
Sensor Type: Pt100 100 Ω @ 0°C 2 or 3 Wire
Sensor Range: -200 to 850°C (-328 to 1562°F)
Sensor Connection: Screw terminal
Minimum Span: 25°C (77°F)
Linearisation: BS EN 60751(IEC 751) standard/JISC 1604
Measurement Accuracy: 0.1°C ±0.05% of reading
Thermal Drift: 25 ppm/°C
Excitation Current: <200 uA
Lead Resistance Effect: 0.002°C/Ω
Maximum Lead Resistance: 20 Ω per leg

Output
Output Type: 2 wire, 4 to 20 mA current loop
Output Range: (4.0 to 20.0) mA
Output Connection: Screw terminal
Maximum Output: 21.5 mA (in high burnout condition)
Minimum Output: 3.8 mA (in low burnout condition)
Accuracy: (mA output /2000) or 5 uA (whichever is the greater)
Loop Voltage Effect: 0.2 uA/V
Thermal Drift: 1 uA /°C
Maximum Output Load: [(Vsupply-10)/20]K Ω
(Example: 700 Ω @ 24V)

General Specifications
Update Time: 500 mS
Response Time: 1 second
Start Up Time: 4 seconds (I out < 4 mA during start up)
Warm-Up Time: 1 minute to full accuracy
Power Supply: 10 to 30 Vdc

Environmental
Ambient Operating Range: -40 to 85°C (-40 to 185°F)
Ambient Storage Temperature: -50 to 90°C (-58 to 194°F)
Ambient Humidity Range: 10 to 90% RH non condensing

Physical
Dimensions: 43 diameter; 21 mm height (1.7; 0.8")
Weight: 31 g (0.068 lb) (encapsulated)
Approvals
EMC - BS EN 61326 :1998: Electrical equipment for measurement control and laboratory use
ANNEX A: Immunity test requirements for equipment intended for use in industrial locations
ANNEX F: Test configurations, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61000-4-2: Electrostatic discharge
IEC 61000-4-3: EM field
IEC 61000-4-4: Transient burst (output)
IEC 61000-4-5: Surge (output)
Note: Sensor input wires to be less than 3 m to comply.
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
TX12
TX12
SGD177.60
Availability: 1 week
 
RTD transmitter (100 OHM, Pt 0.00385)
TX13
TX13
SGD204.80
Availability: 1 week
 
ThermocoupleTransmitter (K, J, N, E, T, R, S and mV Inputs) (see related products, below)
Accessories
TX2-100
TX2-100
SGD82.08
Availability: 7 weeks
 
2-conductor shielded cables, 30 m (100')
PSR-24S
PSR-24S
Consult Sales  
Availability: 
 
 
Regulated power supply, 24 Vdc, 400 mA, screw terminal
PSR-24L
PSR-24L
Consult Sales  
Availability: 
 
 
Regulated power supply, 24 Vdc, 400 mA, UL, stripped leads
  
PSR-24L-230
SGD157.37
Availability: 1 week
 
Regulated power supply, 24 Vdc, 400 mA, stripped leads, 230 Vac input, CE
TX-SCALED
TX-SCALED
Consult Sales  
Availability: 
 
 
Scaling charge for factory set up of range (specify temperature range)
All prices on this site are shown in Singapore Dollars.
Note: Comes with operator’s manual.
Ordering Example: (1) TX12 RTD transmitter (100 Ohm, Pt 0.00385), SGD177.60