Toll-Free in Philippines: 1 800 8908 8267 | 1 800 1441 0877
International+65 6415 5353

Toroidal Conductivity or Concentration Analyzer

CDCN442

Toroidal Conductivity or Concentration Analyzer | CDCN442

Toroidal Conductivity or Concentration Analyzer

PHP62,755.55 CDCN442

CE
  • NEMA 4X (IP68) Case
  • 2 x 16 Digit LCD Readout
  • Assembly in 51 mm (2") Tube or Flat Surface or Panel 144 x 144 x 100 mm DIN (5.7 x 5.7 x 4")
  • Simple 3 Key Operation
  • Offers Cell Check
  • RS485 Output, ModBus and Proprietary Communication Protocol
Conductivity Instrumentation - View related products

Description

The CDCN442 toroidal conductivity system isdesigned for online monitoring of chemically aggressive process solutions, water applications that coat or foul traditional sensors, and plating bath operations in which high current densities are present. The sensor consists of 2 metallic ribbon coils that are fixed in place by the sensor jacket material. The drive coil is used to induce a current in the process solution. The second sensing coil is used to measure the current in the process solution; the magnitude of this current is proportional to the conductivity of the process solution. Toroidal sensors are available in polypropylene, and PEEK™ to ensure that sensor-wetted materials are chemically resistant to process chemicals. The sensor material is nonconductive, thereby isolating the sensor from electrical noise and ground loops that can influence the integrity of the measurement. This material also makes the sensor resistant to electrode coating, since most substances do not adhere to the sensor material. Sensors can be submersion mounted for easy installation in open tanks or pipe mounted in the optional 51 mm (2") tee fitting, which is keyed to the sensor for proper alignment. Tee fitting material is polypropylene. For larger pipe diameters, the sensor can be insertion mounted through a 11.2 NPT ball valve for easy retraction. The monitor comes with concentration/temperature tables for sodium hydroxide, potassium hydroxide, hydrochloric acid, nitric acid, and sulfuric acid. A configurable table allows the user to enter data points for a custom concentration curve. Typical applications include waste water treatment, power plants, thermo electric plants, pharmaceutical, photographic industries, soft drinks industries.

Element Range Element Range
HNO3 0 to 280 g/L H2SO4 940 to 998 g/L
HF 0 to 300 g/L H2CrO4 0 to 100 g/L
NaOH 0 to 150 g/L NaCl 0 to 260 g/L
NaOH 150 to 500 g/L K2CO3 0 to 315g/L
H2SO4 0 to 300 g/L Na2SO4 0 to 220 g/L
H2SO4 350 to 800 g/L HCl 200 to 350 g/L

SPECIFICATIONS
General
Construction Materials:
   Case: Aluminum (SAE323)
   Faceplate: ABS
   Anti-Corrosion Treatment: Finished with electrostatic epoxy paint
Power Consumption: 3.5 VA
Operation: 90-240 Vac 50/60Hz
Weight: 1.3 kg (2.8 lb)
Analyzer
Conductivity Range: 1 µS/cm to 1 S/cm
Resistivity Range: 10 MΩ/cm to infinity
Resolution: 0.1 or 0.01
Temperature Compensation: 0 to 100°C (32 to 212°F), Automatic or Manual
Operating Temperature: 5 to 40°C (41 to 104°F)
Cell Constants Offered: 0.01, 0.1, 1, 5 or 10 cm-1
Transmitter
Analog Output: 4 to 20 mA (2), recorder output
Impedance: 600 Ω
Optical Galvanic Isolation: 2000 Vac
Controller
On/Off Alarm Outputs (2): NO (1A / 240 Vac)
Control Output (4 to 20mA): can be programmed as P + I + D Control
CDE-442
   Range: 1 mS to 1 S
   Body Material: PVDF
   Temperature: 0 to 130°C (32 to 266°F)
   Insertion length: 100 mm (3.93")
   Process Connection: ¾ NPT
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
  
CDCN442
PHP62,755.55
Availability: 1 week
 
Conductivity and concentration analyzer
  
CDE-442
Consult Sales  
Availability: 
 
 
Toroidal conductivity cell (1 required)
CDSA-10
CDSA-10
PHP4,739.05
Availability: 1 week
 
10 micro Siemen conductivity solution
All prices on this site are shown in Philippine Pesos.
Note: Comes complete with hardware for 51 mm (2") tube installation, wall mount brackets, and operator's manual (sensor sold separately).
 
We noticed you are from the US. Visit your local site for regional offers and live support.