SGD730.24 DMD4008

  • For use with Linear Potentiometers or Rotary Potentiometers
  • Voltage, Bidirectional Voltage or Current Outputs
  • Quick Field Setup for Hundreds of I/O Ranges
  • External Switches and Table for Range Selection
  • Removable Plugs for Fast Installation
  • Full 1200V Input/Output Power Isolation
  • Input and Output Tracking LEDs
  • Functional Output Test Button
  • Selectable Sink/Source for Current Output
  • Standard DIN Rail Mounting for Automation Systems
Displacement and Proximity Transducers - View related products

Description

OMEGA's DMD4008 accepts a resistance input from potentiometer, slidewire, linear position, displacement, or rotational devices and provides an optically isolated DC voltage or current output that is linearly related to the potentiometer position. It will accept any potentiometer with a value of 0 to 100 ohms through 0 to 1 Megohms without recalibration and without affecting accuracy. The DMD4008 output can be field configured via external rotary and slide switches, Offsets and/or input ranges other than 0 to 100% of the potentiometer range can also be selected.

Specifications
Potentiometer Input Ranges: Field selectable ranges via switch settings 3 wire connection required
    Minimum: 0 to 100 Ω
    Maximum: 0 to 1 Megohms
    Input Span: 10 to 100% of potentiometer range
    Input Offset: 0 to 90% in 10% increments
Input Impedence: 10 Megohms minimum
Output Ranges: Field selectable ranges via switch settings
    Voltage: 0-1 V to 0-10 Vdc, 10 mA maximum
    Bipolar Voltage: ±5 Vdc or ±10 Vdc
    Current: 0-2 mADC to 0-20 mAdc 20V compliance, 1000 Ω at 20 mA
Output Linearity: Better than ±0.1% of span
Output Zero and Span: Multi-turn potentiometers to compensate for load and lead variations, ±15% of span adjustment range typical.
Output Loop Supply Power: 20 Vdc nominal, regulated, 25 mAdc maximum, ripple, less than 10mVrms may be selectively wired for sinking or sourcing mA output
Output Test: Front button sets output to test level when pressed, potentiometer adjustable 0 to 100% of span
Response Time: 70 milliseconds typical
Common Mode Rejection: 120 dB minimum
Isolation: 1200 Vrms minimum
    Full Isolation: power to input, power to output, input to output
Ambient Temperature Range and Stability: -10°C to 60 operating ambient; better than ±0.02% per °C stability
Standard Power: 60 to 265 Vac, 50/60 Hz or 85 to 300 Vdc, 2W maximum
Low Voltage Option: 9 to 30 Vdc, or 10 to 32 Vac
Housing: Mounts to standard 35 mm DIN rail, IP40 environmental rating
Connectors: Four 4-terminal removable connectors 14 AWG maximum wire size
Dimensions: 22.5 W x 117 H x 122 mm D (0.89 x 4.62 x 4.81") height includes connectors
Place Order(Specify Model Number)
Part Number/Desc.
Qty
Description
DMD4008
SGD730.24
Availability: 6 weeks
 
Standard power input, potentiometer input to DC transmitters
DMD4008-DC
SGD730.00
Availability: 1 week
 
Low power input, potentiometer input to DC transmitters
All prices on this site are shown in Singapore Dollars.
Note: Comes complete with operator’s manual.
Ordering Example: (1) DMD4008 DIN Rail transmitter for linear or rotary potentiometers, SGD730.24
We noticed you are from the US. Visit your local site for regional offers and live support.