Industrial Control Transformers - Stepdown Voltage Converters
Power Transformers
Single Phase Transformers
VA Load for 50-500
Input Voltages 240/480 to 120 Vac
Input Voltages 208/230/450 to 24/115 Vac
Models with Integral Fuse Blocks
Transformers provide stepped down
voltages to machine tool control devices
enabling control circuits to be isolated from
all power and lighting circuits. This allows
the use of grounded or ungrounded circuits
that are independent of the power or lighting
grounds; greater safety is afforded the
operator. The control transformer line is
particularly adaptable on applications where
compact construction is demanded.
Single-Phase Transformers How to Select Single-Phase Units
Determine the primary (source) voltage
(the voltage presently available).
Determine the secondary (load) voltage
(the voltage needed at the load).
Determine the load VA:
Multiply load Volts x load Amps to get the VA rating.
Select a transformer rating equal to or
greater than the load VA.
MODEL NO.
VA
DIMENSIONS: MM (INCHES)
WEIGHT KG (LBS)
WIRING DIAGRAM
HEIGHT
WIDTH
DEPTH
C0050E2A
50
65 (2.56)
76 (3)
76 (3)
1.2 (2.6)
1
C0075E2A
75
65 (2.56)
76 (3)
89 (3.5)
1.6 (3.5)
1
C0100E2A
100
73 (2.875)
86 (3.375)
86 (3.375)
1.9 (4.2)
1
C0150E2A
150
81 (3.187)
95 (3.75)
102 (4)
3 ( 6.7)
1
C0200E2A
200
97 (3.812)
114 (4.5)
102 (4)
3.9 (8.5)
1
C0250E2A
250
97 (3.812)
114 (4.5)
111 (4.375)
10 (4.5)
1
C0300E2A
300
97 (3.812)
114 (4.5)
121 (4.75)
5.1 (11.3)
1
C0500E2A
500
121 (4.75)
133 (5.25)
140 (5.5)
8.7 (19.2)
1
C0050E2AFB
50
100 (3.937)
76 (3)
76 (3)
1.3 (2.8)
1
C0075E2AFB
75
100 (3.937)
76 (3)
89 (3.5)
1.7 (3.7)
1
C0100E2AFB
100
108 (4.25)
86 (3.375)
86 (3.375)
2.0 (4.4)
1
C0150E2AFB
150
116 (4.562)
95 (3.75)
102 (4)
3.1 (6.9)
1
C0200E2AFB
200
132 (5.187)
114 (4.5)
102 (4)
3.9 (8.7)
1
C0250E2AFB
250
132 (5.187)
114 (4.5)
111 (4.375)
4.6 (10.2)
1
C0300E2AFB
300
132 (5.187)
114 (4.5)
121 (4.75)
5.2 (11.5)
1
C0350E2AFB
350
132 (5.187)
114 (4.5)
133 (5.25)
6.3 (13.8)
1
C0500E2AFB
500
156 (6.125)
133 (5.25)
140 (5.5)
8.8 (19.4)
1
C0050E5E
50
65 (2.56)
76 (3)
83 (3.25)
1.5 (3.4)
2
C0100E5E
100
81 (3.187)
95 (3.75)
143 (5.625)
2.7 (5.9)
2
C0150E5E
150
81 (3.187)
95 (3.75)
111 (4.375)
3.6 (7.9)
2
Part Number
Availability
Price
Description
INDUSTRIAL CONTROL TRANSFORMERS CPT
C0050E2A
Consult sales
50 VA, 240/480 to 120 VAC
C0075E2A
$164.00
75 VA, 240/480 to 120 VAC
C0100E2A
$186.00
100 VA, 240/480 to 120 VAC
C0150E2A
8 Weeks
$189.00
150 VA, 240/480 to 120 VAC
C0200E2A
Consult sales
200 VA, 240/480 to 120 VAC
C0250E2A
Consult sales
250 VA, 240/480 to 120 VAC
C0300E2A
Consult sales
300 VA, 240/480 to 120 VAC
C0500E2A
Consult sales
500 VA, 240/480 to 120 VAC
C0050E5E
Consult sales
50 VA, 208/230/460 to 24/115 VAC
C0100E5E
Consult sales
100 VA, 208/230/460 to 24/115 VAC
C0150E5E
8 Weeks
$271.00
150 VA, 208/230/460 to 24/115 VAC
TRANSFORMERS WITH PRIMARY FUSE BLOCK - USES 10 X 38 MM FUSES (13/32 X 1.5")
C0050E2AFB
Consult sales
50 VA, 240/480 to 120 VAC
C0075E2AFB
$189.00
75 VA, 240/480 to 120 VAC
C0100E2AFB
$207.00
100 VA, 240/480 to 120 VAC
C0150E2AFB
Consult sales
150 VA, 240/480 to 120 VAC
C0200E2AFB
$276.00
200 VA, 240/480 to 120 VAC
C0250E2AFB
Consult sales
250 VA, 240/480 to 120 VAC
C0300E2AFB
Consult sales
300 VA, 240/480 to 120 VAC
C0350E2AFB
Consult sales
350 VA, 240/480 to 120 VAC
C0500E2AFB
Consult sales
500 VA, 240/480 to 120 VAC
† All dollar amounts on this site are shown in US currency.