Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Thailand: 001 800 441 0237
International+65 6415 5353

pH, ORP and Conductivity Controller and Transmitter

PHUCN601, PHUCN610, PHUTX601

pH, ORP and Conductivity Controller and Transmitter | PHUCN601, PHUCN610, PHUTX601

pH, ORP and Conductivity Controller and Transmitter

See All Models Below

  • For pH, ORP, Conductivity/Resistivity
  • 1/4 DIN, NEMA 4X, Polycarbonate Enclosure
  • User-Friendly Design with Interior LCD Menu
  • Easy to Read with Large, Bright LED Display
  • Quick and Easy to Calibrate
  • Reduces Chemical Consumption with Cycle Timed Relays on Controllers
  • Two Control Relays with Third Relay for High/Low Alarm on Controllers
Industrial pH Instrumentation and Electrodes - View related products

Description

The PHUCN600 Series multi-parameter controller is a microprocessor-based controller capable of measuring one of the following parameters, pH, ORP, or conductivity.
When shipped from the factory, the PHUCN600 Series is not set to measure any one parameter.When the PHUCN600 Series is powered up for the first time, it will display the meter selection screen where the meter type must be selected. This meter selection screen will only be displayed when the PHUCN600 Series is powered up for the first time.
After the user selects a meter type the PHUCN600 Series will remain set to that meter type until it is changed with the meter selection menu function in the Utilities menu.
To return the PHUCN600 Series to its factory settings, the user must re-select the current meter type from the meter selection menu function. This will override all set-points and return all settings back to the factory settings. The PHUCN600 Series User’s menu has been divided into five main categories:
  • Calibration, used to calibrate the PHUCN600 Series with the selected sensor
  • Utilities, used to manually control or override the outputs
  • Setup, used to configure the PHUCN600 Series many options
  • Diagnostics, used to troubleshoot any problems
  • Outputs, used to configure the PHUCN600 Series outputs.
There are two displays on the PHUCN600 Series. A bright LED numeric display with bar graph on the outside front panel, and a 2-line, 16-character LCD display on the inside. The LED readout on the outside panel can be seen several yards away. The distinctive, Color coded bar graph will immediately indicate if you are within the process parameters that you set (green), if the control relays are on (yellow) and if you are in alarm condition (red). This makes diagnosing pump and alarm malfunctions easy. All configuration and control functions are performed on the LCD menu on the inside front panel.
A universal mounting kit is included for surface, panel and pipemount applications. The 1/4" DIN enclosure makes panel-mount cutouts and engineering simple.
Complete and versatile the PHUTX600 is the 1/4 DIN two wire transmitter which can measure Conductivity, pH or ORP. PHUTX600 comes complete with a universal mounting kit for surface, panel and pipe-mount applications. The NEMA 4X 1/4 DIN enclosure is perfect for stand-alone or panel-mount operation.
PHUCN600 and PHUTX600 Series are packaged in a rugged NEMA 4X polycarbonate enclosure making it ideally suited for heavy-duty applications such as industrial wastewater neutralization, municipal water and wastewater, pulp and paper, and process control.

The PHE-600-SB Salt Bridge kit required for use of the pH and ORE sensors is sold separately. pH and ORE sensors can not be used without the Salt Bridge kit.

(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
Controllers
  
PHUCN601
Consult Sales  
Availability: 
 
 
120 Vac pH/ORP conductivity
  
PHUCN610
Consult Sales  
Availability: 
 
 
240 Vac pH/ORPconductivity
Transmitter
  
PHUTX601
Consult Sales  
Availability: 
 
 
Transmitter pH/ORP conductivity
Electrodes with 1 1/2 NPT, 4.6 m (15') 5 conductor shielded cable, -5 to 95°C (23 to 203 °F)
  
PHE-600
Consult Sales  
Availability: 
 
 
1 1/2 NPT differential pH electrode, PPS sensor body 180 mm (7.1") long 55 mm (2.14") diameter
  
ORE-600
THB32,020.00
Availability: 1 week
 
1 1/2 NPT differential ORP electrode, PPS sensor body 180 mm (7.1") long 55 mm (2.14") diameter
Electrodes with 1 1/4" compression fitting for variable insertion, 4.6 m (15') 5 conductor shielded cable, -5 to 95°C Wetted materials: CPVC PVDF glass titanium palladiam alloy and EPDM (platinum for ORP probe) psig max: 6.9 bar (100 psig)
  
PHE-610
THB36,375.00
Availability: 1 week
 
Compression fitting pH electrode for 7/8" to 5" variable insertion, 229 mm (9") long, 28 mm (1.125") diameter
  
ORE-610
THB33,045.00
Availability: 9 weeks
 
Compression fitting ORP electrode for 7/8" to 5" variable insertion
  
PHE-620
THB36,375.00
Availability: 5 weeks
 
Hot tap pH electrode for extended lengths 7/8" to 6" variable insertion
  
ORE-620
THB35,605.00
Availability: 9 weeks
 
Hot tap ORP electrode for extended lengths 7/8" to 6" variable insertion
Conductivity cells with 3/4 MNPT CPVC compression fitting, auto. temp. Compensation: 0 to 100°C (32 to 212°F). Wetted materials:Graphite, epoxy, EPDM,& CPVC Max. Press/Temp: 50 psi @60°C, 100 psi @ 50°C, 150 psi @ 20°C cable length: 6.10 m (20')
  
CDE-600-001
THB16,800.00
Availability: 5 weeks
 
0.01 cell constant 0 to 2 µS/cm and 0 to 19.99 MΩ/cm epoxy low temp cond probe
  
CDE-600-01
THB11,010.00
Availability: 5 weeks
 
0.1 cell constant 0 to 20 & 0 to 200 µS/cm epoxy low temp cond probe
  
CDE-600-1
THB11,010.00
Availability: 1 week
 
1 cell constant 0 to 2000 µS/cm epoxy low temp cond probe
  
CDE-600-10
THB11,010.00
Availability: 5 weeks
 
10 cell constant 0 to 20 mS/cm epoxy low temp cond probe
  
CDE-600-50
THB12,045.00
Availability: 5 weeks
 
50 constant 0 to 200 mS/cm epoxy low temp cond probe
Conductivity cells with 3/4 MNPT 316SS compression fitting, auto. temp. Compensation: 0 to 100°C (32 to 212°F). Wetted materials: Graphite, epoxy, polypropylene, & 316SS Max. Press/Temp: 250psi @ 120°C cable length: 6.10 m (20')
  
CDE-610-001
THB20,675.00
Availability: 5 weeks
 
0.01 cell constant 0 to 2 µS/cm & 0 to 19.99 MΩ/cm epoxy high temp cond probe
  
CDE-610-01
THB15,765.32
Availability: 1 week
 
0.1 cell constant 0 to 20 and 0 to 200 µS/cm epoxy high temp cond probe
  
CDE-610-1
THB15,765.32
Availability: 1 week
 
1 cell constant 0 to 2000 µS/cm epoxy high temp cond probe
  
CDE-610-10
THB15,765.00
Availability: 5 weeks
 
10 cell constant 0 to 20 mS/cm epoxy high temp cond probe
  
CDE-610-50
THB16,800.00
Availability: 5 weeks
 
50 cell constant 0 to 200 mS/cm epoxy high temp cond probe
Required for Use of pH and ORE Sensors
  
PHE-600-SB
THB8,735.00
Availability: 1 week
 
† Salt Bridge kit kit with PVDF outer junction (3 pack) for required for use with PHE/ORE-600 Series sensors
  
PHE-612-SB
THB8,735.00
Availability: 5 weeks
 
† Salt Bridge kit with PVDF outer junction (3 pack) for PHE/ORE-610/620 Series sensors
pH Accessories
  
PHE-600-C-(*)
Consult Sales  
Availability: 
 
 
$3.00/foot Interconnect cable for PHE/ORE-600 Series
  
PHE-600-EP
THB8,735.00
Availability: 5 weeks
 
Electrode protector
  
PHE-600-JB
THB5,965.00
Availability: 5 weeks
 
Junction box with integrated terminal strip.
  
PHE-610-EP
Consult Sales  
Availability: 
 
 
Electrode protector for PHE/ORE-610/620
  
PHE-620-BVA
Consult Sales  
Availability: 
 
 
PVC hot tap ball valve assembly
PHA-10
PHA-10
THB758.25
Availability: 1 week
 
pH 10 buffer solution 500 ml (1 pt)
PHA-10-GAL
PHA-10-GAL
THB1,895.62
Availability: 3 weeks
 
pH 10 buffer solution 4L (1 gal)
PHA-4
PHA-4
THB717.73
Availability: 1 week
 
pH 4 buffer solution 500 ml (1 pt)
PHA-4-GAL
PHA-4-GAL
THB1,794.32
Availability: 3 weeks
 
pH 4 buffer solution 4 L (1 gal)
PHA-7
PHA-7
THB717.73
Availability: 1 week
 
pH 7 buffer solution 500 ml (1 pt)
PHA-7-GAL
PHA-7-GAL
THB1,794.32
Availability: 1 week
 
pH 7 buffer solution 4 L (1 gal)
PHA-DI
PHA-DI
THB849.97
Availability: 1 week
 
De-ionized water 500 ml (1 pt)
PHA-DI-GAL
PHA-DI-GAL
THB2,121.87
Availability: 1 week
 
De-ionized water 4 L (1 gal)
  
PHAB-DI
THB1,925.00
Availability: 3 weeks
 
20 single use foil packets of de-ionized water
PHAB-PH
PHAB-PH
THB1,926.19
Availability: 1 week
 
5 each single use foil packets of pH-4, pH-7, pH-10, and de-ionized water
All prices on this site are shown in Thai Baht.
Note: Comes complete with operators manual.

* Insert cable length in feet.

†The PHE-600-SB Salt Bridge kit required for use of the pH and ORE sensors is sold separately. pH and ORE sensors can not be used without the Salt Bridge kit.


 

Product Manuals:

Download PHUCN600 - Multi-Parameter Controller & Analyzer (NOTE: 40MB)
Download PHUTX601 - Multi-Parameter Transmitter (NOTE: 21MB)
Download PHE--600/610, ORE-600/610 - Differential pH and ORP Probes
Download CDE-600/610 - Conductivity Cells
We noticed you are from the US. Visit your local site for regional offers and live support.