Relative Humidity Transmitters

HX92B

Relative Humidity Transmitters | HX92B

Relative Humidity Transmitters

See All Models Below

CE
  • 4 to 20 mA, 0 to 1 Vdc, 0 to 5 Vdc or 0 to 10 Vdc Outputs
  • Accurate to ±2.5% (20 to 80% Relative Humidity)
  • Rugged Industrial Splashproof Enclosure NEMA 13 (IP54)
  • Duct Mount Kit Included with Duct Mount and Remote Probe Models
  • Field Replaceable Sensor Probe (Except for Duct Mount Model)
Relative Humidity Measurement Instruments - View related products

Description

The HX92B Series transmitters provide remote and on-site monitoring of relative humidity. It is available with either voltage or 2-wire current output. The transmitter output is linearized and temperature compensated. Current output models enable placing of the transmitter at a remote location virtually any distance away from the measuring device. All models use an accurate digital sensor. A stainless steel mesh type filter, easily removable for cleaning, protects the sensor. Mounting screws are easily accessible inside the rugged, polycarbonate enclosure which protects the electronics to NEMA 13 (IP54) specifications.

Specifications
Input Power
    4 to 20mA: 9 to 30Vdc @ 50mA
    0 to 1V: 9 to 30Vdc @ 50mA
    0 to 5V: 9 to 30Vdc @ 50mA
    0 to 10V: 12 to 30Vdc @ 50mA
Measuring Range: 0 to 100% RH
Accuracy: ±2.5% from 20 to 80% RH; ±3.5% from 5 to 20% and 80 to 95% RH; ±4% from 0 to 5% and 95 to 100% RH
Output:
    HX92BC: 4 to 20 mA for 0 to 100% RH
    HX92BV0: 0 to 1 Vdc for 0 to 100% RH
    HX92BV1: 0 to 5 Vdc for 0 to 100% RH
    HX92BV2: 0 to 10 Vdc for 0 to 100% RH
Relative Humidity Temperature Compensation: -30 to 75°C (-22 to 167°F)
Relative Humidity Response Time: 8 second typical
Repeatability: ±0.1% RH
Sample Rate: 1 sample every 4 seconds
Housing: Gray polycarbonate, NEMA 13 (IP54)
Connections: Liquid-tight nylon with neoprene gland, for 2.29 to 6.73 (0.09 to 0.265")diameter cable; internal 5 position terminal block accepts 14 to 22 gauge wire
Dimensions:
    HX92B(*) (without Probe): 65 L x 50 W x 34.8 D mm (2.56 x 1.97 x 1.37")
    TP-SP (Short Probe): 16 dia. x 71.88 L mm (0.63 x 2.83")
Weight:
    HX92B(*): 124 g (4.4 oz)
    HX92B(*)-D: 132 g (4.7 oz)
    HX92B(*)-RP1: 230 g (8.1 oz)
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
  
HX92BC
TWD13,149
Availability: 7 weeks
 
Wall mount relative humidity transmitter, 4 to 20 mA
  
HX92BC-D
TWD13,730
Availability: 17 weeks
 
Duct mount relative humidity transmitter, 4 to 20 mA.
  
HX92BC-RP1
TWD16,369
Availability: 7 weeks
 
Remote probe relative humidity transmitter, 4 to 20 mA
  
HX92BV0
TWD13,870
Availability: 7 weeks
 
Wall mount relative humidity transmitter, 0 to 1 volt output
  
HX92BV1
TWD13,149
Availability: 7 weeks
 
Wall mount relative humidity transmitter, 0 to 5 volt output
  
HX92BV2
TWD12,681
Availability: 1 week
 
Wall mount relative humidity transmitter, 0 to 10 volt output
  
HX92BV0-D
TWD13,730
Availability: 17 weeks
 
Duct mount relative humidity transmitter, 0 to 1 volt output.
  
HX92BV1-D
TWD13,728
Availability: 17 weeks
 
Duct mount relative humidity transmitter, 0 to 5 volt output.
  
HX92BV2-D
TWD13,730
Availability: 17 weeks
 
Duct mount relative humidity transmitter, 0 to 10 volt output.
  
HX92BV0-RP1
TWD16,370
Availability: 7 weeks
 
Remote probe relative humidity transmitter, 0 to 1 volt output
  
HX92BV1-RP1
TWD16,370
Availability: 7 weeks
 
Remote probe relative humidity transmitter, 0 to 5 volt output
  
HX92BV2-RP1
TWD16,370
Availability: 7 weeks
 
Remote probe relative humidity transmitter, 0 to 10 volt output
Accessories
HX92-CAL
HX92-CAL
TWD6,398
Availability: 5 weeks
 
Calibration kit, 11 and 75% relative humidity standards
  
TH-RP
TWD6,085
Availability: 1 week
 
Field replaceable remote probe with 3 m (10') cable and M12 connector
  
TH-SP
TWD6,085
Availability: 1 week
 
Field replaceable 71.88 L mm (2.83') short probe with M12 connector
  
IND-KIT
TWD611
Availability: 1 week
 
Spare duct mount kit for HX92B Duct Mount and Remote Probe models.
All prices on this site are shown in Taiwan Dollars.
Note: Comes complete with Quick Start Manual.

Product Manuals:

Download Quick Start - Relative Humidity Transmitters
Download Relative Humidity Transmitters
We noticed you are from the US. Visit your local site for regional offers and live support.