instruNet Series Direct Sensor to Data Acquisition

iNET-100

instruNet Series Direct Sensor to Data Acquisition | iNET-100

instruNet Series Direct Sensor to Data Acquisition

TWD54,736 iNET-100

CE
  • High Accuracy Data Acquisition for Windows-Based Computers
  • 16 Single-Ended/8 Differential 14 Bit Analog Inputs, 8 Analog Outputs and 8 Digital I/O
  • iNET-240 USB 2.0 Controller Card
  • Direct Connect to RTD, Thermocouple, Voltage, Thermistor, Bridge and Strain Gage Sensors
  • 166 ks/sec Throughput to RAM or Disk
  • Each Channel has Independently Programmable Analog Filters, Integration Time, Voltage Range and Sample Rate
  • Programmable Digital Filters on All Channels
  • Includes Strip/Chart Software and Drivers for C, Visual Basic, and TestPoint Optional LabVIEW Drivers are available.
USB, RS232, RS485 and Ethernet Data Acquisition Systems - View related products

Description

instruNet provides ten's of microvolts of absolute accuracy instead of ten's of millivolts, at the same cost and at the same throughput rates as typical general purpose data acquisition boards. It does this with a completely different topology where the analog electronics are close to the sensor in electrically quiet boxes outside your PC, and noisy digital electronics are left inside the computer.
The external boxes contain signal conditioning amplifiers for each channel and can directly attach to sensors such as thermocouples, thermistors, RTDs, strain gages, resistance sources, current sources and voltage sources. The box returns engineering units to your PC (e.g. °C, Volts, Amps).
At the heart of the real-time system is a PCI card (WIN XP/VISTA (32-bit)/7 (32-bit), PC-card (WIN XP/VISTA (32-bit)/7 (32-bit) or USB 2.0 (WIN XP SP2/VISTA 32-bit or 64-bit/7 32-bit or 64-bit) controller. Each controller contains a 32 bit microprocessor with 256KB of RAM that manages the external "network" of devices. All real-time tasks are off-loaded to this processor, therefore the host computer is not burdened with real-time issues.
Each instruNet iNET-100 box provides, 16 single-ended/8 differential analog inputs, 8 analog outputs and 8 digital I/O lines. The iNET-100 includes 44 screw terminals. The iNET-100B version adds 16 BNCs for analog inputs.
The controller's themselves provide 10 counter/timer channels each of which can function as a digital input bit, a digital output bit, a clock output channel or a period measurement input channel.


Distributed and Expandable
The instruNet system is ideally suited for distributed measurement and control systems. The network cable can extend up to 1000 feet. Each controller card in the PC can connect to up to 16 instruNet boxes for a total number of 256 analog inputs, 128 analog outputs and 128 digital I/O. For additional inputs, multiple controller cards can be placed in one computer with the maximum number of controller cards limited only by the number of available slots in the computer. Since each controller card has its own microprocessor, multiple cards do not place any additional burden on the computer. It should be noted that multiple instruNet boxes on a single network may degrade the maximum system throughput of 166Ks/sec.

High Current Version (HC)
The INET-100HC is similar to the INET-100, yet the voltage output channels have a higher drive capability, providing up to 15 mA of current to capacitive loads as high as 0.01µF. The INET-100 and INET-100B devices support only 4mA/.001µF voltage output drive. The INET-100HC is recommended for use with sensors that require excitation, such as strain gages, RTDs and thermistors since these sensors may exceed the current or capacitive drive limits of the INET-100 or INET-100B. The INET-100HC provides greater compatibility with sensors that have capacitive loading on the excitation lines, therefore, the HC version is recommended for all sensors requiring excitation including RTDs and thermistors. Since the HC version has a greater power demand, an external power supply must be used. The INET-312-8 can be used to power up to three INET-100HC boxes.

Software
instruNet World, is a FREE application program. It manages, monitors and operates the instruNet system. It digitizes long continuous waveforms, spools them to disk, views incoming waveforms in real-time and then allows post acquisition viewing-much like an oscilloscope or strip chart recorder. instruNet World provides a spreadsheet-like environment where one can set and view channel parameters such as sensor type, integration time, analog filter, and digital filter. Each channel has it's own row in the spreadsheet, with the various options in the columns. instruNet is also compatible with a variety of off-the-shelf software products including TEST Point; Microsoft Excel 8 for Windows, DasyLab and Labtech Notebook (consult the factory for the availability of DasyLab drivers). For users writing their own programs, instruNet includes drivers callable from any 32 bit C compiler, and Visual Basic (v4.0 or greater). The driver includes a main routine, called "iNet( )", that reads or writes any of the options or channels on the system. Optional drivers are also available for LabVIEW software.
  


InstruNet World Plus Software (for Windows XP/VISTA/7)
InstruNet World Plus Software is an option that adds valuable features to the standard instruNet World software which is included with instruNet hardware. It enables one to digitize, plot, control, analyze, and save to disk A/D, D/A, and digital I/O data from InstruNet hardware. Additionally, it enables one to define their own instrument front panel with buttons, popup menus, edit fields, dynamic text, text editor regions, and waveform graphs. InstruNet World Plus is programmed with a simple script language that can define tasks such as control loops. For example, one can type "Dac1 = OnOff (Ain1, 3)" to define D/A #1 as a function of A/D #1.

Specifications
Analog Inputs Number: 16 single-ended/8 differential
Resolution: 14-bit
System Throughput: 166k samples/sec
A/D Conversion Time: 4 µs min
Signal To Noise Ratio: 78 dB
Linearity: Differential ±1.5 LSB; Integral ±2 LSB
Input Overvoltage Protection: ±15 V
Input Impedance: >22 MΩ, 3pf
Common Mode Voltage: ±5 V min (CMR ±80 dB)
Gain and Offset Drift: ±5 ppm/°C of 5 V FSR; offset self calibrated to 0 Thermistor Accuracy/Ranges All OMEGA™ 44xxx series thermistors supported. (Contact factory for other thermistors.) One user supplied shunt resistor per thermistor channel is required.
Range Shunt Accuracy
-80 to 40°C 47 kΩ ±0.2°C
0 to 70°C 4.7 kΩ ±0.1°C
0 to 200°C 200Ω ±0.4°C
Analog Outputs Number: 8
Resolution: 8 bit
Output Range: ±5 V @ 5 mA for iNET-100/100B, ±5 V @15 mA for iNET-100HC
Output Protection: Short-to-ground continuous
Output Settling Time: 4µs (to ±1/2 LSB, ±5 V step)
Analog Output Accuracy: ±0.4%
Digital Coupling: ±20 mV
Gain and Offset Drift: ±10 ppm/°C of 5 V FSR; and ±5 µV/°C offset drift
Digital I/O Number: 8 non-latching inputs and 8 latching outputs at 8 bi-directional screw terminals
Input Levels:
VIH = 3.2 V min to 12 V max;
VIL = 1.0 V max to -12 V min
IIH = -200 µA, Vi = 3.2 V;
IIL = -0.5 mA max.
Output Levels:
VOH = 2 V min to 5 V max;
IOH = -0.5 mA max.
IOL = 500 mA max, VO=1.7 V;
IOL = 50 mA max, VO = 0.7 V

For additional information on InstruNet World Plus software see the "Related Links" section below.

For user manuals and application notes visit the instrunet web site.
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
External Boxes
INET-100
INET-100
TWD54,736
Availability: 1 week
 
instruNet external A/D box with screw terminals
INET-100B
INET-100B
TWD59,766
Availability: 1 week
 
instruNet external A/D box with screw terminal and BNC connections
INET-100HC
INET-100HC
TWD59,766
Availability: 4 weeks
 
Same as INET-100 with 15 mA excitation current
Controller Cards
iNET-240
iNET-240
TWD19,571
Availability: 1 week
 
USB 2.0 controller for Windows XP SP2//VISTA (32-bit of 64-bit)/7 (32-bit or 64-bit); requires inet-312-8 power supply
INET-200
INET-200
TWD29,720
Availability: 4 weeks
 
PCI Bus controller card for Windows 95/NT/98/2000/XP or Macintosh computers
INET-230
INET-230
TWD29,720
Availability: 4 weeks
 
PC-Card controller, type II for Windows XP/VISTA (32-bit)/7 (32-bit) (does not provide power, requires iNET-312-8 power supply)
Power Supplies and Accessories
iNET-iWPLUS
iNET-iWPLUS
TWD13,797
Availability: 1 week
 
instruNet World Plus Software. Data acquisition and control software for the instruNet systems. See the Related Links section below for addtional details on instruNet World Plus software.
INET-300
INET-300
TWD3,374
Availability: 1 week
 
Power adaptor, required if using more than 2 iNET-100/100B boxes or one iNET-100HC boxes with the iNET-200 PCI controller card
INET-330
INET-330
TWD20,057
Availability: 6 weeks
 
Optical isolator
INET-340
INET-340
TWD4,615
Availability: 6 weeks
 
DIN rail mounting brackets for one INET-100
INET-380
INET-380
TWD9,362
Availability: 6 weeks
 
LabVIEW drivers (LabVIEW versions 4-6 currently supported on Windows 98/NT/XP
INET-312-8
INET-312-8
TWD8,504
Availability: 1 week
 
Power supply, 110/220 Vac, 5V/2A, ±12V/0.8A, USA plug used with iNET-300/330/230 (powers 3 additional iNET-100HC or 4 additional iNET-100/100B), includes iNET-300 power adaptor
  
INET-312-8EU
TWD8,505
Availability: 1 week
 
Power supply, 110/220 AC, 5V/2A, ±12V/0.8A, Euro plug, used with iNET-300/330/230 (powers 3 additional iNET-100HC or 4 additional iNET-100/100B), includes iNET-300 power adaptor
  
INET-34W3F
TWD1,410
Availability: 6 weeks
 
3 ft 34 wire ribbon cable
iNET-CABLE-10ft
iNET-CABLE-10ft
TWD1,355
Availability: 6 weeks
 
instruNet cable, 10 ft (3.0 m) length
iNET-CABLE-25ft
iNET-CABLE-25ft
TWD2,153
Availability: 6 weeks
 
instruNet cable, 25 ft (7.6 m) length
iNET-CABLE-50ft
iNET-CABLE-50ft
TWD3,030
Availability: 6 weeks
 
instruNet cable, 50 ft (15.2 m) length
  
iNET-CABLE-100ft
TWD5,025
Availability: 6 weeks
 
instruNet cable, 100 ft (30.5) length
Resistors
  
OMX-R20
TWD193
Availability: 7 weeks
 
20 Ohm resistor, ±0.1% accuracy
  
OMX-R100
TWD63
Availability: 1 week
 
100 Ohm resistor, ±0.1% accuracy
  
OMX-R250
TWD126
Availability: 1 week
 
250 Ohm resistor, ±1% accuracy
  
RES-250
TWD625
Availability: 1 week
 
250 Ohm resistor, ±0.1% accuracy
  
OMX-R200
TWD635
Availability: 7 weeks
 
200 Ohm resistor, ±0.1% accuracy
  
OMX-R1K
TWD1,595
Availability: 1 week
 
1000 Ohm resistor, ±0.025% accuracy
  
OMX-R2K
TWD935
Availability: 1 week
 
2000 Ohm resistor, ±0.025% accuracy
  
OMX-R4.7K
TWD1,000
Availability: 7 weeks
 
4700 Ohm resistor, ±0.025% accuracy
  
OMX-R10K
TWD635
Availability: 1 week
 
10,000 Ohm resistor, ±0.025% accuracy
  
OMX-R20K
TWD635
Availability: 7 weeks
 
20,000 Ohm resistor, ±0.025% accuracy
  
OMX-R47K
TWD1,190
Availability: 7 weeks
 
47,000 Ohm resistor, ±0.025% accuracy
All prices on this site are shown in Taiwan Dollars.
Note: The iNET-2xx controllers include a complete user’s manual, instruNet World data acquisition software, driver software and network terminator. The iNET-100/100B includes a 10 ft. connecting cable.
Ordering Example: 

(1) INET-100B instruNet external A/D box with screw terminal and BNC connections, TWD59,766  plus (1) INET-200 PCI controller card, TWD29,720  plus (1) INET-230 PCI Bus controller card, TWD29,720  plus (1) INET-312-8 Power supply, TWD8,504, TWD59,766 + 29,720 + 29,720 + 8,504 = TWD127,710