Insensitive to Fluid Density and Fluid Viscosity Changes
NEMA 4X (IP66)
Description
The FMG80 series has been discontinued. Please see the FMG80A Series as a possible alternative or contact our Flow Engineering department.
The FMG80 Series magmeter is
designed for low-flow chemical
injection or difficult-to-meter
applications with pulsating metering
pumps in ¾ to ¼" pipe/tube. The
housing is made of sturdy splashproof
HDPE plastic.
With no moving parts, the FMG80
Series can handle fluids containing
particulate matter without clogging
or jamming, keeping maintenance
at a minimum. With no metallic
parts (100% PVDF body and PVDF
carbon fiber-filled electrodes), the
meter is corrosion-resistant and
compatible with a wide range of
chemicals. Accuracy is maintained
with conductive fluids (>20 micro
Siemens) of varying viscosities
and densities.
The FMG80 Series meter is
compact enough to fit most
pump/injection systems. With zero
straight pipe required after an
elbow, it can be easily mounted in
tight spaces. The mounting bracket
adds stability.
The FMG80 Series meter has
opto-coupled current sinking or
current sourcing pulse as well as a
4 to 20 mA output that can be
connected to many OMEGAR panel
meters, controllers and data
loggers; outputs and power are
provided through a 6 m (18') cable
with 8-pin female circular connector.
SPECIFICATIONS
Pipe Sizes: ¼, 3⁄8, ½, and ¾" Fittings: Fittings with two NPT threaded adaptors (included) Materials Body: PVDF Electrodes: PVDF carbon fiber-filled Ground: PVDF carbon fiber-filled Housing: HDPE with glass fiber Fittings: PVDF Adaptors (NPT): PVDF O-Rings: EPDM or FKM (-FKM) Temperature: Ambient: -18 to 54°C (0 to 130°F) Fluid: 0 to 93°C (32 to 200°F) Pressure: 150 psi Flow Range: FMG81, FMG82: 3 GPM max (0.03 GPM cut off) FMG83, FMG84: 20 GPM max (0.2 GPM cut off) Accuracy: FMG81, FMG82: ±1%, ±0.002 GPM of reading across rated range FMG83, FMG84: ±1%, ±0.005 GPM of reading across rated range Output Signal: Optocoupled current sinking or current sourcing pulse output; 30 Vdc, 5 mA max, 4 to 20 mA current loop; 7 Vdc plus load voltage drop min; 50 Vdc max FMG81, FMG82: 1000 pulses/liter (3785 pulses/gallon) FMG83, FMG84: 500 pulses/liter (1892 pulses/gallon) Power: 10 to 15 Vdc, 150 mA (linear power supply recommended) Fluid Conductivity: >20 microSiemens Environmental: NEMA 4X (IP66) Cable Length: 6m (19.7') w/8-pin Female Circular Connector
† All prices on this site are shown in Singapore Dollars. Note: Comes complete with 6m (19.7') cable with 8-pin female circular connector and operator’s manual.
Ordering Example: (1) FMG80-CABLE 2.4 m (8') cable, SGD176.00
We noticed you are from the US. Visit your local site for regional offers and live support.