Sanitary Pressure Transmitter with Amplified Voltage Output
High 0.08% Accuracy

PX409S-5V Sanitary Series

Sanitary Pressure Transducers
PX409S, PX419S, PX429S, PX459S | PX409S-5V Sanitary Series

SGD1,730.00 PX429S20-100G5V

CE
  • FAST DELIVERY! Stock to 1-Week!
  • High 0.08% Accuracy
  • Solid State Sensor for Durability
  • Excellent Long Term Stability
  • 316L SS Wetted Parts
  • Shock and Vibration Rated
  • High Overpressure Rating
  • Ruggedized with Secondary Containment
  • Now Available with M12 Connector, Order Model PX459
  • 0-5 Vdc or 0-10 Vdc Output
  • Gage and Absolute Pressure to 600 psi
    Compound Gage ±10 inH2O to ±15 psi
    Sealed Gage 100 to 600 psi
    Vacuum 10 inH2O to 15 psi
  • 5-pt NIST Traceable Calibration Included
Pressure Transducers - View related products

Description

3-A approvedThe PX409S Series sanitary pressure transducers and sanitary pressure transmitters are made using our proven micromachined silicon process. They are available with 1½ or 2 in sanitary fittings and are designed for long reliable service in pressure or level CIP applications in food processing, beverage or bio/ pharmaceutical applications as well as industrial applications that require a rugged, high accuracy transducer. The micro-machined silicon sensor provides a very stable transducer with exceptional high accuracy of 0.08% and a broad compensated range of -4 to 85°C (25 to 185°F). The modular construction allows for fast delivery of most configurations and fittings.

SPECIFICATIONS
Accuracy: 0.08% Best Straight Line (Linearity, Hysteresis and Repeatability combined)
Operating Temperature Range: -15 to 115°C (-5 to 240°F)
Compensated Temperature Range: -4 to 85°C (25 to 185°F)
Temperature Compensation: Zero and Span Combined
    ≥5psi: 1% over 55.6°C (100°F) range
    ≤2.5 psi: 2% over 55.6°C (100°F) range
Min Isolation Between Case and Output Terminations: 100 MΩ @ 50 Vdc
Pressure Cycles: 250,000 minimum
Long Term Stability (1-Year): ±0.1% FS typ.
Shock: 50 g, 11 ms half sine shock, (under test)
Vibration: ±20 g (under test)
Bandwidth: DC to 1 kHz typical
Response Time: <1 ms
Fill Fluid: NEOBEE M5 Food grade
CE Compliant: Meets industrial emissions and immunity standard IEC61326
Environmental Protection: IP65 or IP67 depending upon electrical termination
Pressure Rating: 1½ and 2 in Tri-Grip™ (Tri-Clamp® compatible) fitting: 600 psi using suitable clamp
Over Pressure: 4 x rated pressure to maximum rated flange pressure
Secondary Containment: 6 x rated pressure to a maximum of 2000 psi (not in clamp)
Wetted Parts: 316L SS
Weight: 285 gm (10 oz)
Zero Balance: ±0.5% FS typical, 1% max (For ranges ≤2.5 psi ±1% typ 2% max)
Span Setting: ±0.5% FS typical, 1% max (For ranges ≤2.5 psi, ±1% typ 2% max)
Calibrated in vertical position with fitting down
10 mV/V OUTPUT
     Output/Supply: 10 mV/V; Ratiometric 5 to 10 Vdc
AMPLIFIED VOLTAGE OUTPUT
    Output/ Supply:
    0 to 5 Vdc: 10 to 30 Vdc @ 10 mA
    0 to 10 Vdc: 15 to 30 Vdc @ 10 mA
CURRENT OUTPUT
    Output: 4 to 20 mA
    Supply Voltage: 9 to 30 Vdc max loop res Ω = (Vs-9)x50 [9 to 20 Vdc above 105°C (229°F)]


Please use the part number builder below to select the model and options required to meet your requirements.
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
MOST POPULAR MODELS
Use the part number builder below to order models not shown. Specify the fitting size, pressure range, output, and electrical termination desired.
1½ inch Flange, Gage Pressure, Cable Connection, 0 to 5 Vdc Output
  
PX409S15-10WG5V
Consult Sales  
Availability: 
 
 
0-10 inH2O gage pressure Range
  
PX409S15-001G5V
Consult Sales  
Availability: 
 
 
0-1 psig Range
  
PX409S15-2.5G5V
Consult Sales  
Availability: 
 
 
0-2.5 psig Range
  
PX409S15-005G5V
Consult Sales  
Availability: 
 
 
0-5 psig Range
  
PX409S15-015G5V
Consult Sales  
Availability: 
 
 
0-15 psig Range
  
PX409S15-030G5V
SGD1,730.00
Availability: 7 weeks
 
0-30 psig Range
  
PX409S15-050G5V
Consult Sales  
Availability: 
 
 
0-50 psig Range
  
PX409S15-100G5V
SGD1,730.00
Availability: 7 weeks
 
0-100 psig Range
  
PX409S15-150G5V
Consult Sales  
Availability: 
 
 
0-150 psig Range
  
PX409S15-250G5V
Consult Sales  
Availability: 
 
 
0-250 psig Range
  
PX409S15-500G5V
Consult Sales  
Availability: 
 
 
0-500 psig Range
  
PX409S15-600G5V
Consult Sales  
Availability: 
 
 
0-600 psig Range
1½ inch Flange, Absolute Pressure, Cable Connection, 0 to 5 Vdc Output
  
PX409S15-005A5V
Consult Sales  
Availability: 
 
 
0-5 psia Range
  
PX409S15-015A5V
Consult Sales  
Availability: 
 
 
0-15 psia Range
  
PX409S15-030A5V
Consult Sales  
Availability: 
 
 
0-30 psia Range
  
PX409S15-050A5V
Consult Sales  
Availability: 
 
 
0-50 psia Range
  
PX409S15-100A5V
Consult Sales  
Availability: 
 
 
0-100 psia Range
  
PX409S15-150A5V
Consult Sales  
Availability: 
 
 
0-150 psia Range
  
PX409S15-250A5V
Consult Sales  
Availability: 
 
 
0-250 psia Range
  
PX409S15-500A5V
Consult Sales  
Availability: 
 
 
0-500 psia Range
  
PX409S15-600A5V
Consult Sales  
Availability: 
 
 
0-600 psia Range
2 inch Flange, Gage Pressure, Cable Connection, 0 to 5 Vdc Output
  
PX409S20-10WG5V
Consult Sales  
Availability: 
 
 
0-10 inH2O gage pressure Range
  
PX409S20-001G5V
Consult Sales  
Availability: 
 
 
0-1 psig Range
  
PX409S20-2.5G5V
Consult Sales  
Availability: 
 
 
0-2.5 psig Range
  
PX409S20-005G5V
Consult Sales  
Availability: 
 
 
0-5 psig Range
  
PX409S20-015G5V
Consult Sales  
Availability: 
 
 
0-15 psig Range
  
PX409S20-030G5V
Consult Sales  
Availability: 
 
 
0-30 psig Range
  
PX409S20-050G5V
Consult Sales  
Availability: 
 
 
0-50 psig Range
  
PX409S20-100G5V
Consult Sales  
Availability: 
 
 
0-100 psig Range
  
PX409S20-150G5V
Consult Sales  
Availability: 
 
 
0-150 psig Range
  
PX409S20-250G5V
Consult Sales  
Availability: 
 
 
0-250 psig Range
  
PX409S20-500G5V
Consult Sales  
Availability: 
 
 
0-500 psig Range
2 inch Flange, Absolute Pressure, Cable Connection, 0 to 5 Vdc Output
  
PX409S20-005A5V
Consult Sales  
Availability: 
 
 
0-5 psia Range
  
PX409S20-015A5V
Consult Sales  
Availability: 
 
 
0-15 psia Range
  
PX409S20-030A5V
Consult Sales  
Availability: 
 
 
0-30 psia Range
  
PX409S20-050A5V
Consult Sales  
Availability: 
 
 
0-50 psia Range
  
PX409S20-100A5V
Consult Sales  
Availability: 
 
 
0-100 psia Range
  
PX409S20-150A5V
Consult Sales  
Availability: 
 
 
0-150 psia Range
  
PX409S20-250A5V
SGD1,730.00
Availability: 7 weeks
 
0-250 psia Range
  
PX409S20-500A5V
Consult Sales  
Availability: 
 
 
0-500 psia Range
Accessories
PT06F10-6S
PT06F10-6S
SGD65.77
Availability: 1 week
 
Mating connector (sold separately) for PX429S Series
M12C-PVC-4-S-F-5
M12C-PVC-4-S-F-5
SGD38.87
Availability: 1 week
 
5 m (16 ft) PVC cable, straight 4-pin M12 female connector one end, fluing leads one end.
M12C-PVC-4-R-F-5
M12C-PVC-4-R-F-5
SGD41.06
Availability: 1 week
 
5 m (16 ft) PVC cable, right angled 4-pin M12 female connector one end, fluing leads one end.
All prices on this site are shown in Singapore Dollars.
Note: 5-point NIST traceable calibration included

Option Descriptions:


(1) Electrical Termination select from:
PX409S for 2 m (6 ft) cable
PX409CS for conduit/cable
PX419S for mini DIN
PX429S for Twist-Lock connector
PX459S for M12 Connector

(2) Process Fitting select from:
15 for 1.5 inch Tri-Grip
20 for 2 inch Tri-Grip (500 psi max)

(3) Range select from:
10W for 0 to 10 in H2O
001 for 0 to 1 psi
2.5 for 0 to 2.5 psi
005 for 0 to 5 psi
015 for 0 to 15 psi
030 for 0 to 30 psi
050 for 0 to 50 psi
100 for 0 to 100 psi
150 for 0 to 150 psi
250 for 0 to 250 psi
500 for 0 to 500 psi
600 for 0 to 600 psi (1-1/2 Clamp only)

(4) Pressure Type select from:
G for Gage pressure
CG for Compound Gage Pressure (10W to 015 Ranges)
SG for Hermetically Sealed Gage (PX429 or PX449 and Ranges >=100 psi )
A for absolute pressure (5 to 600 psia)
V for Gage Vacuum (10W to 015 Ranges)

(5) Output Type select from:
V for 10 mV/V
5V for 0 to 5 Vdc
10V for 0 to 10 Vdc
I for 4 to 20 mA
Note: All combinations may not be valid, check spec sheet for valid part numbers.