Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Malaysia: 1800 88 3496
International+65 6415 5353

Compressed Air Dewpoint Monitor

RHB-CAC1S Series

Compressed Air Dewpoint Monitor | RHB-CAC1S Series

Compressed Air Dewpoint Monitor

See All Models Below

CE
  • NIST Traceable
  • +/- 0.2 deg C
  • Virtually Maintenance Free
  • Easy to Install
  • Self-Monitoring
  • User-Programmable Audible and Visual Alarms and Relay Contact
  • Programmable Automatic Balance Control (ABC)
  • Widest Available Range of -60 to 50°C (-76 to 122°F)
Relative Humidity Measurement Instruments - View related products

Description

These compressed air dewpoint monitors have been designed to offer the highest level of reliability and accuracy available in such systems. They are fully NIST traceable and employ a chilledmirror sensor, the most accurate dewpoint sensing scheme available, to deliver consistent drift-free measurements without regular calibrations or sensor replacement.
These compressed air monitors are complete dewpoint measuring systems. The ruggedized aluminum NEMA 12 (IP55) enclosure houses the sensor, control circuitry (including flow control) and is easily wall mounted to conserve space. Only the sample line and power connection are needed for the system to be operational.
The monitors also offer a programmable automatic balance control (ABC) cycle that corrects for the light-reducing effects of mirror contaminates and allows for continuous monitoring and virtually maintenance-free operation.

Specifications:
DEW/FROST POINT RANGE
Two-Stage (S2): -40 to 50°C (-40 to 122°F)
Three-Stage (S3): -60 to 50°C (-76 to 122°F)
Dew/Frost Point Accuracy: 0.20°C (±0.5°F)

FUNCTIONALITY
Power: 90 to 250 Vac, 50 to 400 Hz
Operating Temperature: 0 to 50°C (32 to 122°F)
Sample Connection: 1/4" compression fitting
Sample Flow Rate: 0.5 to 5 SCFH; integral flowmeter
Sample Pressure: 0 to 150 psig
(higher pressures available, consult Engineering Department)
Output: Analog: 4 to 20 mA (0 to 5 Vdc), 50 to 50°C (-58 to 122°F) or
-75 to 75°C (-103 to 167°F)
Compliance: 9.0 Vdc, 450 .
Display: Red LED, 0.5" tall; 8-digit alphanumeric

ALARM:
Audible: >98 dba @ 2'
Relay: 1 Form C, non-latching 10 A @ 240 Vac, 8 A @ 24 Vdc, 1/2 HP @ 240 Vac
Visual: Flashing “ALARM” message
(Specify Model Number)
Part Number/Desc.
Qty
Description
RHB-CAC1S2C
SGD12,015.00
Availability: 7 weeks
 
2 Stage Dew Point Monitor
RHB-CAC1S2-RHB-ATP
SGD12,869.09
Availability: 7 weeks
 
2 Stage Dew Point Monitor W/ATC probe
All prices on this site are shown in Singapore Dollars.
We noticed you are from the US. Visit your local site for regional offers and live support.