SGD161.52 SA1-RTD

  • Surface Mount RTD 100 Ω DIN Class A (±0.06 Ω or ±0.15°C at 0°C) Accuracy Standard
  • Easy-Installation Silicone-Based, Self-Adhesive Backing Rated to 260°C (500°F)
  • Back Can be Reapplied
  • Temperature Range; -73C to 260°C Continuous, 290°C (554°F) Short Term Operation When Installed with OMEGABOND Air Set Cements
  • Stripped 3-Wire Leads Standard (Connectors Optional), Color Code: Black/Black/Red
  • Optional 4-Wire Configuration (Color Code: Black/Black/Red/Red)
  • Stocked in 1 m (40") Lengths; Also Available in 2 and 3 m (80 and 120") and Custom Length Lead Wires
  • Other Resistances/Accuracies Available on Request
  • Stainless Steel Overbraid Option to reduce electrical noise and protect lead wire from abrasion
RTD (PT100)  Probes, Elements and Assemblies - View related products

Description

SPECIFICATIONS
Minimum/Maximum Temperature: -73°C (-100°F) to 260°C (500°F) continuous, 290°C (554°F) short term (when cemented in place)
Sensing Element: 100 Ω at 0°C (32°F), temp coefficient of 0.00385 Ω/Ω/°C (IEC60751)
Accuracy: ±0.06% at 0°C (Pt100 DIN Class A)
Stability: Less than 0.2°C drift/year
Response Time: Less than 1sec. in water (63% response), less than 2sec. on a hot plate
Self-Heating Effect: 2.5 mW/°C
Lead Wire: 1 m (40"), 26 AWG, nickel-plated copper, PFA-insulated 3-wire, Color Code: Black/Black/Red

The SA1-RTD surface-mount RTD temperature sensor mounts on flat or curved surfaces and provides Class A accuracy (See IEC 751 Class A/B Standard Tolerances Table, below) for critical temperature monitoring applications. Based on a 2 x 2 x 0.8 mm Pt100 thin-film and supplied with bare 3-wire leads as a standard configuration (connector optional), it can be customized for use in a wide variety of applications. The surface mount temperature sensor can be easily applied with its self-adhesive backing, or positioned permanently with OMEGABOND™ cements.

Use the SA1-RTD to monitor chip, heat sink, and environmental temperatures in electronic devices; check piping or ducting temperatures; monitor motor and transformer core heat; test insulation capabilities; and check other applications in which surface and/or gradient temperatures need to be monitored or controlled


Also Available with Stainless Steel Overbraid
For applications where electrical noise is prevalent or where sensor lead wire is being routed around sharp edges, the stainless steel overbraid option (-SB) reduces noise and safeguards wire leads. Add "-SB" to the end of the part number listed in the table on the spec sheet, and add $3.50/ft.

IEC 751 Class A/B Standard Tolerances
Temp.
(°C)
Tolerance Class
Class A*Class B
±°C±Ω±°C±Ω
-2000.550.241.30.56
-1000.350.140.80.32
0.00.150.060.30.12
1000.350.130.80.30
2000.550.201.30.48
3000.750.271.80.64
4000.950.332.30.79
5001.150.382.80.93
6001.350.433.31.06
*SA1-RTDs are IEC 751 Class A Devices.

(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
SA1-RTD
SA1-RTD
SGD161.52
Availability: 1 week
 
3-wire Pt100, 40 Inches (1m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)
  
SA1-RTD-SB
SGD201.72
Availability: 1 week
 
3-wire Pt100, 40 Inches with SS Over braiding (1m), Stripped leads, 1 1/2" (1" insulated singles, 1.2" bare)
SA1-RTD-80
SA1-RTD-80
SGD182.74
Availability: 5 weeks
 
3-wire Pt100, 80 Inches (2m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)
SA1-RTD-80-SB
SA1-RTD-80-SB
SGD223.32
Availability: 1 week
 
3-wire Pt100, 80 Inches with SS Over braiding 2m (80 in), Stripped leads, 1 1/2" (1" insulated singles, 1.2" bare)
  
SA1-RTD-120-SB
Consult Sales  
Availability: 
 
 
3-wire Pt100, 120 Inches with SS Over braiding (3m), Stripped leads, 1 1/2" (1" insulated singles, 1.2" bare)
SA1-RTD-120
SA1-RTD-120
SGD202.78
Availability: 1 week
 
3-wire Pt100, 120 Inches (3m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)
  
SA1-RTD-MTP
SGD183.92
Availability: 1 week
 
3-wire Pt100, 40 Inches (1m), 'MTP' style miniature flat 3-pin connector
  
SA1-RTD-80-MTP
SGD216.00
Availability: 5 weeks
 
3-wire Pt100, 80 Inches (2m), 'MTP' style miniature flat 3-pin connector
  
SA1-RTD-120-MTP
SGD225.18
Availability: 5 weeks
 
3-wire Pt100, 120 Inches (3m), 'MTP' style miniature flat 3-pin connector
SA1-RTD-4W
SA1-RTD-4W
SGD178.02
Availability: 1 week
 
4-wire Pt100, 40 Inches (1m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)
SA1-RTD-4W-80
SA1-RTD-4W-80
SGD199.24
Availability: 1 week
 
4-wire Pt100, 80 Inches (2m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)
SA1-RTD-4W-120
SA1-RTD-4W-120
SGD219.29
Availability: 1 week
 
4-wire Pt100, 120 Inches (3m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)
  
SA1-RTD-4W-TA4F
SGD238.00
Availability: 5 weeks
 
4-wire Pt100, 40 Inches (1 m), 'TA4F' style round audio connector
  
SA1-RTD-4W-80-TA4F
SGD245.00
Availability: 5 weeks
 
4-wire Pt100, 80 Inches (2 m), 'TA4F' style round audio connector
  
SA1-RTD-4W-120-TA4F
SGD281.00
Availability: 5 weeks
 
4-wire Pt100, 120 Inches (1 m), 'TA4F' style round audio connector
Accessories
450-APT
450-APT
Consult Sales  
Availability: 
 
 
Handheld thermometer, RTD input
HH804
HH804
SGD254.69
Availability: 1 week
 
Handheld, Dual Input, Pt3926, Pt3916 and Pt385 RTD Thermometer, Min/Max/Avg, Rel, Hold functions, Accuracy: ± 0.05%; Includes male Mini Din mating connectors
TA4F
TA4F
SGD25.47
Availability: 1 week
 
Cord Plug, Female, Max Cable Diameter (mm/in) 2.9 (0.114), No. Pins at Contact 4
  
SA1-RTD-4W-120-SB
SGD285.15
Availability: 5 weeks
 
Surface RTD, 4 wire, 3m (120 in), steel braid
  
SA1-RTD-ROHS
SGD170.59
Availability: 1 week
 
Surface RTD, 3 wire, 1m (40 in)
All prices on this site are shown in Singapore Dollars.
Note: For special lengths of lead wire, add $2.25/ft. For an SA1-RTD with TA4F connector installed (SA1-RTD-4W-TA4F), $73.00; SA1-RTD-4W-80-TA4F, $80.50; SA1-RTD-4W-120-TA4F, $88.00. For more information, see the spec sheet or contact Sales.


(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
Ordering Example: (1) SA1-RTD-80-MTP Class A, surface-mount Pt100 sensor, 3-wire leads, 2 m (80'') lead-wire length with a miniature 3-pin MTP connector Class A, surface-mount RTD sensor, 4 wire leads, 2 m (80'') lead-wire length with a 4-pin, SGD216.00

Option Descriptions:


(1) Wire Style select from:
Nothing(leave field blank) for 3-Wire
-4W for 4-Wire

(2) Wire Length select from:
Nothing(leave field blank) for 1 m (40 in)
-80 for 2 m (80 in)
-120 for 3 m (120 in)

(3) Cold End Termination select from:
Nothing(leave field blank) for Stripped leads 1 1/2 (1 in insulated singles 1/2 in bare)
-MTP for MTP style miniature flat 3-pin connector
-TA4F for TA4F Connector. Pins 1 and 2 common 3 and 4 common

(4) Additional Option select from:
Nothing(leave field blank) for None
-SB for stainless steel overbraid
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.