Toll-Free in Philippines: 1 800 8908 8267 | 1 800 1441 0877
International+65 6415 5353

CL540ZA

Thermocouple Simulator | CL540ZA

Thermocouple Simulator

PHP79,780.60 CL540ZA

CE
  • Source 14 Thermocouple Types
  • Easy-to-Read Backlight Display
  • Easily Change Thermocouple Types and Scale
  • Calibrate Directly in Temperature (°C or °F)
  • Compatible with All Process Instruments
Precision Calibration Equipment and Ice Point References - View related products

Description

With the CL540ZA you can check and calibrate all your thermocouple instruments. Connect via a miniature thermocouple connector on the top end of the source. Use your own thermocouple wire connectors or order one of the cable accessories for easy operation out of the box. Easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a millivolt source and thermocouple tables. The CL540ZA works with the thermocouples you use including Types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Easily set any value quickly to within 0.1° with the adjustable digital potentiometer “DIAL” plus store any three temperatures for instant recall with the selector switch. You can also calibrate from -13.000 to +80.000 mV. Connect directly to the thermocouple inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their outputs or displays.

SPECIFICATIONS
Accuracy: ±(0.015% of Reading + 0.006 mV)
Cold Junction Compensation: ±0.25°C (±0.45°F)
Operating Temperature Range: -25 to 60°C (-10 to 140°F)
Millivolt Range: -13.000 to 80.000 mV
Relative Humidity Range: 10% ≤ RH ≤ 90% 0 to 35°C (32 to 95°F), non-condensing. 10% ≤ RH ≤ 70% 35 to 60°C (95 to 140°F), non-condensing
Dimensions: 126 L x 69 W x 45 mm D (4.96 x 2.73 x 1.79")
    With Boot: 144 L x 78 W x 52 mm D (5.67 x 3.06 x 2.05")
Weight: 238 g (8.4 oz) (including batteries)
    With Boot: 311.8 g (11 oz) (including batteries)
Batteries: Four "AA" Alkaline 1.5V (included)
Battery Life: 50 hours
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 Vdc (rated for 30 seconds)
Display: High contrast graphic liquid crystal display. LED backlighting for use in low lit areas
Source
    Output Impedance: < 0.3 Ω
    Source Current: > 20 mA (drives 80 mV into 10 Ω)
    Noise: ≤4 microvolts p-p for frequencies of 10 Hz or below
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
CL540ZA
CL540ZA
PHP79,780.60
Availability: 1 week
 
Thermocouple simulator
Accessories
SC-530
SC-530
Consult Sales  
Availability: 
 
 
Soft carrying case
020-0209
020-0209
PHP6,905.15
Availability: 1 week
 
Rubber boot
CL-300-CABLE-J-2
CL-300-CABLE-J-2
PHP1,106.96
Availability: 5 weeks
 
0.6 m (2') thermocouple cable, SMP male to spade lugs, Type J
CL-300-CABLE-J-10
CL-300-CABLE-J-10
PHP2,175.00
Availability: 1 week
 
3 m (10') thermocouple cable, SMP male to spade lugs, Type J
  
CL-300-RSC-J-2
PHP2,219.87
Availability: 1 week
 
Retractable cable 0.6 m (2'), Type J

Order By Part Number

Part Number
Qty
Part Number
Qty


All prices on this site are shown in Philippine Pesos.
Note: Comes complete with NIST certificate, one red and black lead set with retractable shield banana plugs with alligator clips, 4 "AA" alkaline batteries, and operator’s manual.