FMA-LP1600A
Mass Flow Meter | Gas Flow
PHP113,753.82
FMA-LP1603A
-
Ranges of 0 to 0.5 SCCM Up to 0 to 500 SLM
-
Reports Mass Flow, Volumetric Flow, Temperature, and Pressure
-
<10 ms Response Time—Field Adjustable
-
130+ Gas Calibrations, Including Air, Ar, CH4, CO, CO2, Ethane, H2, He, N2, N2O, Neon, O2, Propane, Butane, Iso-Butane, Acetylene, Ethylene, Krypton, Xenon, and Sulfur Hexafluoride
-
Pressure, Temperature and Volumetric and Mass Flow Simultaneously Displayed
-
NIST 5-Point Certificate Included
-
No Straight Runs of Pipe Required
-
No Warm-Up Time
-
Turndown Ratio of 200:1 (0.5% Maximum Flow)
-
RS232 Standard
-
Portable Battery Powered units (-B models)
Electronic Mass Flow Meters & Controllers - View related products
† All prices on this site are shown in Philippine Pesos.
Note: Comes complete with 24 Vdc universal power supply, 1.8m (6') cable, 8-pin male Mini- DIN connector, operator’s manual, and NIST certificate.
Units are calibrated to air @ 5 psig for 0 to 1 LPM, 15 psig for 2 to 10 LPM, 30 psig for 20 to 100 LPM, and 50 psig for 200 LPM and greater.
Calibrations done at ambient (25C/77F) temperature only.
To replace the standard RS232 communications with RS485, add suffix “-RS485” to the model number; add $120 to the price.
Standard input is 0 to 5V, for optional 4 to 20 mA input add suffix “-IN” to the model number; no additional cost.
Standard output is scaled to the mass flow rate.
For volumetric flow rate as standard output add suffix “-VOL” to the model number; no additional cost.
**Optional secondary output are scaled the same as the primary output scale. For an alternate output scale add suffix “-T” to the model number
for temperature or “-P” for pressure; no additional cost.
††Portable versions have an integral battery compartment
on the meter and come with one 9V battery installed. Option not available on “-I” or “I2” models where 4 to 20mA is the chosen output.
For units scaled in SCFH, add suffix “-SCFH” to model number; no additional cost. Please specify the desired range in SCFH.
For totalizer option, add suffix “-TOT” to the model number; add $120 to the price. Please specify resolution. This is a 6-digit counter. Examples: For totalizing in liters with 1/100 liter resolution, the max count would be 9999.99. For totalizing in liters with 1 liter resolution, the max count would be 999999.
Ethernet/IP, DeviceNet, Modbus and Profibus communications are also available for an additional charge.
Option Descriptions:
(1)
Max Flow select from:01 for 0.5 SCCM
02 for 1 SCCM
14 for 2 SCCM
15 for 5 SCCM
03 for 10 SCCM
16 for 20 SCCM
04 for 50 SCCM
17 for 100 SCCM
18 for 200 SCCM
19 for 500 SCCM
20 for 1 SLM
05 for 2 SLM
06 for 5 SLM
07 for 10 SLM
08 for 20 SLM
09 for 50 SLM
10 for 100 SLM
11 for 250 SLM
12 for 500 SLM
(2)
Output select from:Nothing(leave field blank) for None
-I for 4 to 20 mA output
-I2 for Two 4 to 20 mA outputs
-V2 for Two 0 to 5V Outputs
-I2-T for Two 4 to 20 mA outputs second output for temperature
-V2-T for Two 0 to 5V outputs second output for temperature
-I2-P for Two 4 to 20 mA outputs second output for pressure
-V2-P for Two 0 to 5V outputs second output for pressure
-VOL for Volumetric flow rate as standard output
(3)
Portable Version select from:Nothing(leave field blank) for Standard
-B for Portable version of the meter (not available on models with 4 to 20 mA output)
(4)
Input select from:Nothing(leave field blank) for 0 to 5V
-IN for 4 to 20 mA input
(5)
RS485 select from:Nothing(leave field blank) for RS232
-RS485 for RS485
(6)
SCFH select from:Nothing(leave field blank) for Standard
-SCFH for Units scaled in SCFH
(7)
Totalizer select from:Nothing(leave field blank) for Standard
-TOT for Totalizer
Note: All combinations may not be valid, check spec sheet for valid part numbers.