Option Descriptions:
(1)
Chart Recorders select from:RD101A for 1-channnel recorder with 100 mm (4 inch) continuous recording
RD102A for 2-channnel recorder with 100 mm (4 inch) continuous recording
RD103A for 3-channnel recorder with 100 mm (4 inch) continuous recording
RD104A for 4-channnel recorder with 100 mm (4 inch) continuous recording
RD106A for 6-channnel recorder with 100 mm (4 inch) dot recording
RD1801 for 1-channnel recorder with 180 mm (7 inch) continuous recording
RD1802 for 2-channnel recorder with 180 mm (7 inch) continuous recording
RD1803 for 3-channnel recorder with 180 mm (7 inch) continuous recording
RD1804 for 4-channnel recorder with 180 mm (7 inch) continuous recording
RD1806 for 6-channnel recorder with 180 mm (7 inch) dot recording
RD1812 for 12-channnel recorder with 180 mm (7 inch) dot recording
(2)
Options (Not Field Installable) select from:Nothing(leave field blank) for Standard Unit
-24V for 24 Vdc Power (Not Available on Portable Unit)
-AR for 4 alarm outputs remote control (RD100A series only)
-AR-24V for 4 alarm outputs remote control (RD100A series only) and 24 Vdc power (not available on portable unit)
-AR-S4 for 4 alarm outputs remote control (RD100A series only) and RS-422A communications
-AR-S4-24V for 4 alarm outputs remote control (RD100A series only) - RS-422A communications and 24 Vdc power (not available on portable unit)
-AR6 for 6 alarm outputs remote control (RD106A and RD1800 series)
-AR6-24V for 6 alarm outputs remote control (RD106A and RD1800 series) and 24 Vdc Power (not available on portable unit)
-AR6-S4 for 6 alarm outputs remote control (RD106A and RD1800 series) and RS-422A communications
-AR6-S4-24V for 6 alarm outputs remote control (RD106A and RD1800 series) - RS-422A communications and 24 Vdc Power (not available on portable unit)
-AR12 for 12 alarm outputs and remote control (RD1806/RD1812/RD1818/RD1824 only)
-AR12-24V for 12 alarm outputs and remote control (RD1806/RD1812/RD1818/RD1824 only)
-AR12-S4 for 12 alarm outputs and remote control (RD1806/RD1812/RD1818/RD1824 only)
-AR12-S4-24V for 12 alarm outputs and remote control (RD1806/RD1812/RD1818/RD1824 only) with RS-422A communications and 24 Vdc Power (not available on portable unit)
-AR24 for 24 alarm outputs and remote control (RD1824 only)
-AR24-24V for 24 alarm outputs and remote control (RD1824 only) and 24 Vdc Power (not available on portable unit)
-AR24-S4 for 24 alarm outputs and remote control (RD1824 only) and RS-422A communications
-AR24-S4-24V for 24 alarm outputs and remote control (RD1824 only) with RS-422A communications and 24 Vdc Power (not available on portable unit)
-P for Portable handle/rubber feet/power cord (for 110 Vac) for RD100A series only
-P-AR for Portable handle/rubber feet/power cord (for 110 Vac) for RD100A series only with 4 alarm outputs remote control (RD100A series only)
-P-AR-S4 for Portable handle/rubber feet/power cord (for 110 Vac) - RD100A series only and 4 alarm outputs remote control (RD100A series only) with RS-422A communications
-P-AR-S4-24V for Portable handle/rubber feet/power cord (for 110 Vac) - RD100A series only and 4 alarm outputs remote control (RD100A series only) with RS-422A communications and 24 Vdc Power (not available on portable unit)
-S4 for RS-422A communications
-S4-24V for RS-422A communications 24 Vdc Power (not available on portable unit)
(3)
CE Approval select from:Nothing(leave field blank) for Standard Unit
-CE for CE approved - programming prompt In French/German or English (not available on portable unit)
Note: All combinations may not be valid, check spec sheet for valid part numbers.