Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Singapore: 1800 622 1156
International+65 6415 5353

Automated Thermocouple Calibrator

CL541-PLUS

Automated Thermocouple Calibrator | CL541-PLUS

Automated Thermocouple Calibrator

SGD2,982.27 CL541-PLUS

CE
  • Source and Read 4 T/C Types J, K, T AND E Plus mV
  • Easy-to-Read Backlight Display
  • Easily Change T/C Types and Scale
  • Calibrate Quickly With Automatic Output Stepping
  • Comes Protected With a Rugged Rubber Boot
  • Calibrate Directly in Temperature (Deg C or F)
  • Compatible With All Process Instruments
Precision Calibration Equipment and Ice Point References - View related products

Description

With the CL541-PLUS you can check and calibrate all your thermocouple instruments and measure thermocouple sensors. Automatic indication of connections on the display for simple hookups. Take it without worry into the shop, plant or field. It comes protected with a rubber boot and rugged, low profile switch. Easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a millivolt source and thermocouple tables, you can calibrate directly in temperature (°C and °F).

The CL541-PLUS works with the T/Cs you use including types J, K, T and E. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL" plus store any three temperatures for instant recall. Calibrate quickly with automatic output stepping. Choose between 2, 3, 5, 11 and 21 steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of span. Select the step time to match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 and 60 seconds. Connect directly to the thermocouple inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their outputs or displays. Measure and trouble shoot thermocouple sensor connections and find broken wires or high resistance junctions. Connect your sensor and the CL541-PLUS automatically measures the thermocouple in degrees C or F.

SPECIFICATIONS
(Unless otherwise indicated all specifications are rated from a nominal 3°C, 70% RH)
Accuracy: ±(0.008% of Reading + 0.006 mV) Cold Junction
Compensation: ±0.1°F (±0.06°C)
Millivolt Range: -13.000 to 80.000 mV Operating Temperature
Range: -25 to 60°C (-10 to 140°F)
Relative Humidity Range: 10% ≤RH ≤90% (0 to 35°C), non-condensing; 10% ≤RH ≤70% (35 to 60°C), non-condensing
Dimensions: 143 L x 76.2 W x 40.64 mm H (5.63 x 3.00 x 1.60")
Weight: 12.1 oz (including boot and batteries)
Power: 4 "AA" Alkaline 1.5V (included)
Battery Life: 50 Hours
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 Vdc (rated for 30 seconds)
Display: High contrast graphic liquid crystal display. LED backlighting for use in low lit areas.

Read
Input Impedance:
>10 Megohms
Open Thermocouple
    Threshold:
10,000Ω nominal
    Pulse: <10 microamp pulse for 300 milliseconds
Normal Mode Rejection: 50/60 Hz, 50 dB
Common Mode Rejection: 50/60 Hz, 120 dB Source
Output Impedance: < 0.3Ω
Source Current: > 20 mA (drives 80 mV into 10Ω)
Noise: ≤4 microvolts p-p for frequencies of 10 Hz or below
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
  
CL541-PLUS
SGD2,982.27
Availability: 6 weeks
 
Automated thermocouple calibrator
SC-530
SC-530
Consult Sales  
Availability: 
 
 
Replacement soft carrying case
All prices on this site are shown in Singapore Dollars.
Note: Comes complete with rubber boot, 1 red and 1 black leads with retractable shield banana plugs and aligator clips, 4 "AA" alkaline batteries, NIST certificate of calibration, carrying case and operator’s manual.
Ordering Example: (1) CL541-PLUS Automated thermocouple calibrator, SGD2,982.27
We noticed you are from the US. Visit your local site for regional offers and live support.