1/16 DIN Temperature/Process Controllers

CN8501 and CN8502

RTD Controller | CN8501 and CN8502

RTD Controller

See All Models Below

  • NEMA-4X Front Panel
  • User Selectable Ramp to Setpoint
  • Bumpless Auto/ Manual Operation
  • Optional RS-232 or RS-485 Communications
  • Autotuning Heat or Cool
  • Thermocouple, RTD, Voltage, or Current Input
  • Dual Output and Dual Alarm Capability
  • Optional Remote Setpoint, Transducer Power Supply and Recorder Output
  • Optional Power, 24 Vdc/Vac
Temperature and Process Controllers and Power Switching Devices - View related products

Description

The CN8500 temperature controller is extremely versatile and user-friendly. The operator needs to review only those parameters relevant to the particular application during setup. A dual digital display offers optimum process information at a glance. The dedicated upper display shows the process temperature, while the lower display displays setpoint and setup parameters. Individual LED’s identify the status of outputs, alarms, digital communications and special options. The CN8500 features a NEMA-4X front panel and a universal power supply that accepts 103 to 253 Vac and 103 to 330 V dc. Control algorithms available are P, PI, PD, PID, or ON/OFF. The autotune feature automatically sets proportional band, rate and reset before the process reaches setpoint. These parameters provide quick stabilization of both the heating and cooling process without overshoot, hunting or cycling. The standard dual control outputs can be configured in a variety of control and alarm applications such as heat, heat/cool, heat/alarm, cool, or cool/alarm. The Ramp to Setpoint feature allows the user to define the rate of rise to reach the setpoint, thus minimizing thermal shock to the load during start-up.
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
Thermocouple Temperature Sensor Input, One Control Output
  
CN8501TC-R1
TWD18,467
Availability: 1 week
 
Controller with 5A Relay output for Heating (Reverse acting)
  
CN8501TC-R1-A
TWD19,225
Availability: 6 weeks
 
Controller with 5A control relay output for Heating (Reverse acting)
  
CN8501TC-R1-C2
TWD22,745
Availability: 6 weeks
 
Controller with 5A control relay output for Heating (Reverse acting) and RS232
  
CN8501TC-R1-RSP1
TWD21,665
Availability: 6 weeks
 
Controller with 5A control relay output for Heating (Reverse acting) and Remote switch closed
  
CN8501TC-R2-PV2
TWD21,665
Availability: 6 weeks
 
Controller with 5A control relay output for Cooling (Direct acting) and 0 to 5Vdc recorder output
CN8501TC-DC1
CN8501TC-DC1
TWD18,470
Availability: 6 weeks
 
Controller with DC pulse output for Heating (reverse acting)
  
CN8501TC-DC1-A
TWD19,228
Availability: 6 weeks
 
Controller with DC pulse output for Heating (reverse acting) and dual alarms
CN8501TC-DC1-C2
CN8501TC-DC1-C2
TWD25,024
Availability: 1 week
 
Controller with DC pulse output for Heating (reverse acting) and RS232
  
CN8501TC-F1
TWD18,445
Availability: 6 weeks
 
Controller with 4 to 20mA control output
  
CN8501TC-F1-PV1
TWD21,665
Availability: 6 weeks
 
Controller with 4 to 20mA control output and 4 to 20 mA recorder output
  
CN8501TC-F1-C2
TWD22,745
Availability: 6 weeks
 
Controller with TC input, 4-20 mA output and RS232 communications
Thermocouple Temperature Sensor Input, Dual Control Output
  
CN8502TC-R1-R2
TWD20,258
Availability: 1 week
 
Controller with TC input and 2 relay outputs
  
CN8502TC-R1-R2-A
TWD22,935
Availability: 6 weeks
 
Controller with TC input and 2 relay outputs and dual alarms
  
CN8502TC-R1-R2-C2
TWD26,215
Availability: 1 week
 
Controller with TC input and 2 relay outputs and RS232
  
CN8502TC-R1-R2-24V
TWD21,745
Availability: 1 week
 
Controller with TC input, 2 relay outputs and low voltage
  
CN8502TC-R1-R2-A-24V
TWD22,475
Availability: 6 weeks
 
Controller
  
CN8502TC-R1-R2-PV2
TWD23,020
Availability: 1 week
 
Controller
  
CN8502TC-R1-R2-PV1
TWD23,020
Availability: 6 weeks
 
Controller
  
CN8502TC-T1
TWD18,415
Availability: 6 weeks
 
Controller
RTD Temperature Sensor Input, One Control Output
  
CN8501RTD-DC1
TWD16,790
Availability: 6 weeks
 
Controller with DC pulse output for Heating (reverse acting)
  
CN8501RTD-R1
TWD16,790
Availability: 1 week
 
Controller with 5A Relay output for Heating (Reverse acting)
  
CN8501RTD-R1-A
TWD19,225
Availability: 6 weeks
 
Controller with 5A Relay output for Heating (Reverse acting) with alarms
RTD Temperature Sensor Input, Dual Control Output
  
CN8502RTD-DC1-DC2
TWD18,415
Availability: 1 week
 
Controller with RTD input, 2 DC pulse outputs
  
CN8502RTD-R1-R2
TWD20,255
Availability: 1 week
 
Controller with RTD input, 2 relay outputs
  
CN8502RTD-R1-R2-A
TWD20,850
Availability: 6 weeks
 
Controller with RTD input, 2 relay outputs and alarms
  
CN8502RTD-R1-R2-C4
TWD23,830
Availability: 6 weeks
 
Controller with RTD input, 2 relay outputs and RS485
Milliamp Input, One Control Output
  
CN8501MA-R1
TWD18,470
Availability: 1 week
 
Controller with mA input and relay output
  
CN8501MA-F1-C4
TWD22,745
Availability: 6 weeks
 
Controller with mA input, 4-20 mA output and RS485 communications
  
CN8501MA-F1-C2
TWD22,745
Availability: 6 weeks
 
Controller with mA input, 4-20 mA output and RS232 communications
Milliamp Input with Dual Control Output
  
CN8502MA-R1-R2-A
TWD20,850
Availability: 6 weeks
 
Controller
  
CN8502MA-R1-R2-XP1
TWD23,230
Availability: 6 weeks
 
Controller
  
CN8502MA-T1-T2-A
TWD20,850
Availability: 6 weeks
 
Controller
Millivolt Input with One Control Output
  
CN8501MV-R1
TWD16,790
Availability: 6 weeks
 
Controller with mV input and relay output
Millivolt Input with Dual Control Output
  
CN8502MV-R1-R2-RSP3
TWD23,020
Availability: 6 weeks
 
Controller
  
CN8502MV-DC1-DC2-C2
TWD23,830
Availability: 6 weeks
 
Controller
Voltage (Max 5 Volts) Input, One Control Output
  
CN8501V5-DC1-RSP3
TWD21,665
Availability: 6 weeks
 
Controller
  
CN8501V5-F1-C2
TWD22,745
Availability: 6 weeks
 
Controller
Voltage (Max 5 Volts) Input, Dual Control Output
  
CN8502V5-R1-F2
TWD18,415
Availability: 6 weeks
 
Controller
  
CN8502V5-F1-F2
TWD18,415
Availability: 6 weeks
 
Controller
  
CN8502V5-DC1-DC2-C4
TWD23,830
Availability: 6 weeks
 
Controller
Voltage (Max10 Volts) Input, One Control Output
  
CN8501V10-F1
TWD16,790
Availability: 6 weeks
 
Controller
Voltage (Max10 Volts) Input, Dual Control Output
  
CN8502V10-F1-F2-A
TWD20,850
Availability: 6 weeks
 
Controller
  
CN8502V10-F1-F2
TWD18,415
Availability: 6 weeks
 
Controller
All prices on this site are shown in Taiwan Dollars.

Option Descriptions:


(1) Number of Outputs select from:
1 for Single Output
2 for Dual Output

(2) Input Type select from:
TC for Thermocouple
RTD for RTD
MV for Millivolt to 50 mV
V5 for Voltage to 5V
V10 for Voltage to 10 V
MA for Current to 20mA

(3) First Output (Reverse Action Only) select from:
Nothing(leave field blank) for No first output
-R1 for Relay
-DC1 for dc Pulse
-T1 for 1A SSR
-F1 for 4-20 mA

(4) Second Output (Direct Action Only) select from:
Nothing(leave field blank) for No second output
-R2 for Relay
-DC2 for dc Pulse
-T2 for 1A SSR
-F2 for 4-20 mA

(5) Additional Options select from:
Nothing(leave field blank) for No additional options
-A for Dual alarms
-C2 for RS-232 communications
-C4 for RS-485 communications
-XP1 for Transducer power supply 15 Vdc

(6) Low Voltage Power Input Option select from:
Nothing(leave field blank) for Without Low Voltage Input
-24V for With Low Voltage Input Option 24 Vac/dc
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.