Cart  |  Contact  |  Help  | 
Toll-Free in Taiwan: 0809 090 375
International+65 6415 5353

DIN Rail Input Loop-Powered Isolators

DRSL-LPI_Series

Loop-Powered Isolators - DIN Rail Input for galvanic isolation | DRSL-LPI_Series
New

See All Models Below

CE RoHS
  • 1 Channel (DRSL-LPI-1) or 2 Channel (DRSL-LPI-2) Input Loop Powered Isolators
  • Powered by the Analog Input Current Signal Loop
  • 1:1 Signal Ratio
  • Low Input Voltage Drop
  • Fast Response Time <5 ms
  • High Conversion Accuracy, <0.1% of Span (0 to 20.5 mA)
  • Slimline 6 mm (0.24") Housing
Process Measurement and Control Instruments - View related products

Description

The DRSL-LPI Series DIN rail input loop powered isolators provide a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. These units provide isolation and 1:1 conversion of standard current signals and are powered by the analog input current signal loop.

The DRSL-LPI series offers isolation between input and output, provides surge suppression and protects control systems from transients and noise. These units also eliminate ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. These isolators operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

SPECIFICATIONS
NUMBER OF CHANNELS
    DRSL-LPI-1: 1
    DRSL-LPI-2: 2
CURRENT INPUT
Signal Range (Input to Output): 0 to 20.5 mA
Signal Conversion: 1 to 1
Functional Range: 0 to 23 mA (NAMUR NE43 compliant)
Start up Current: 10 µA typical
Input Overload: 50 mA max
Input to Output Voltage Drop: 1.25V + (0.015 x Vout) where Vout = Iout x Routput, typical
Input Voltage Drop: (Unit voltage drop) + Vout
CURRENT OUTPUT
    Output Load: 600Ω max
    Output Load Stability: <0.01% of span/100 Ω (span = 0 to 20 mA)
    Voltage Limit: 17.5V

GENERAL
Internal Consumption: 30 mW per channel
Isolation Voltage (Test): 2.5 kVac
Isolation Voltage (Working): 300 Vac
Signal/Noise Ratio: >60 dB
Cut-Off Frequency (3 dB): 100 Hz
Response Time (0 to 90%, 100 to 10%): <5 ms
Absolute Accuracy (at 25°C): ≤±10 µA + 0.05% of max value of selected span
Temperature Coefficient: ≤±2 µA/°C
EMC Immunity Influence: <±0.5% of span
Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span

ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II

MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm²/AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
RoHS
Description
Quick Ship
  
DRSL-LPI-1
TWD3,890
Availability: 1 week
RoHS compliant
DIN rail input loop-powered isolator, 1 channel
Quick Ship
  
DRSL-LPI-2
TWD5,390
Availability: 1 week
RoHS compliant
DIN rail input loop-powered isolator, 2 channel
Accessories
Quick Ship
RAIL-35-1
RAIL-35-1
TWD400
Availability: 1 week
RoHS compliancy undetermined
35 mm (1.4") DIN rail, 1 m (3.3') length
Quick Ship
  
DRSL-MOD-STOP
TWD186
Availability: 1 week
RoHS compliant
Module stop (screwed onto DIN rail to support and hold mounted devices)
All prices on this site are shown in Taiwan Dollars.
Ordering Example: (1) DRSL-LPI-1 DIN rail input loop-powered isolator, 1 channel, TWD3,890  plus (1) DRSL-MOD-STOP Module stop (screwed onto DIN rail to support and hold mounted devices), TWD186  plus (1) RAIL-35-1 35 mm (1.4, TWD400, TWD3,890 + 186 + 400 = TWD4,476

Product Manuals:

Download Installation Guide for Signal Conditioners
Download DIN Rail Loop Powered Isolators