Cart  |  Contact  |  Help  | 
Toll-Free in Taiwan: 0809 090 375
International+65 6415 5353

Clamp-On Ultrasonic Energy Flow Meter

FDT-40E Series

Clamp-On Ultrasonic Energy Flowmeter
 | FDT-40E Series

Clamp-On Ultrasonic Energy Flowmeter

TWD125,400 FDT-40E

CE
  • Bi-Directional Flow/Energy Measurement
  • Rugged, Aluminum Enclosure
  • Rate and Total Backlit Display
  • 4 to 20 mA and Dual Alarm Outputs
  • USB Programming Port
  • RS485 MODBUS® Network Connection
Doppler/Transit-Time Ultrasonic Flow Meters - View related products

Description

FDT-40E Series ultrasonic flow and energy meters clamp on to the outside of pipes and do not come in contact with the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates. FDT-40E Series is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.

Specifications
System
Liquid Types: Most clean liquids or liquids containing small amounts of suspended solids or gas bubbles
Velocity Range: Bi-directional to greater than 40 FPS (12 MPS)
Flow Accuracy:
    Larger Than 50 mm (2"): ±1% of reading or ±0.01 FPS (0.003 MPS), whichever is greater
    25 to 50 mm (1 to 2"): ±1% of reading or ±0.04 FPS (0.012 MPS), whichever is greater
    19 mm (¾") and Smaller: ±1% of full scale
Temperature Accuracy:
    Absolute: 0.25°C (0.45°F)
    Difference: 0.1°C (0.18°F)
Energy Temperature Range: 0 to 100°C (32 to 212°F)
Sensitivity Flow: 0.001 FPS (0.0003 MPS)
Temperature: 0.025°C (0.05°F)
Repeatability: 0.5% of reading Transmitter
Power Requirements (AC): 95 to 264 Vac 47 to 63 Hz @ 17 VA maximum standard, 20 to 28 Vac 47 to 63 Hz @ 0.35 A maximum (“-24VAC” models), 10 to 28 Vdc @ 5 W maximum (“-VDC” models)
Protection: Auto resettable fuse, reverse polarity and transient suppression
Display: Two line LCD, LED backlit; top row 18 mm (0.7") height, 7-segment; bottom row 9 mm (0.35") height, 14-segment
Icons: RUN, PROGRAM, RELAY1, RELAY2
Flow Rate Indication: 8-digit positive, 7-digit negative maximum; auto decimal, lead zero blanking
Flow Totalizer: 8-digit positive, 7-digit negative maximum (re-set via keypad press, software, network command or momentary contact closure
Enclosure NEMA 4 (IP65) Construction: Powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Size (Electronic Enclosure Only): 152 W x 112 H x 56 mm D (6.0 x 4.4 x 2.2")
Conduit Holes: (2) ½ NPT female (1) ¾ NPT female
Temperature: -40 to 85°C (-40 to 185°F)
RTD: Platinum 385, 1000O, 3-wire
Configuration: Via optional keypad or PC running software (Note: not all configuration parameters are available from the keypad – i.e. flow and temperature calibration and advanced filter settings)
Engineering Units Flow Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs, meters, cubic meters, liters, million liters, kg
Engineering Units Energy Meter: BTU, MBTU, MMBTU, Tons
Inputs/Outputs USB 2.0: For connection of a PC running configuration utility
    RS485: MODBUS RTU command set
    4 to 20 mA: 12-bit, internal power, can span negative to positive flow/energy rates
Transducers
Construction
    Standard (FDT-41 thru 46): NEMA 6 (IP67), PVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 60°C (-40 to 140°F)
    FDT-41 thru 46 with “-HT” option, FDT-47 and FDT-48: NEMA 6 (IP67), CPVC, PEI, Nylon cord grip, PVC cable jacket
    Temperature: -40 to 90°C (-40 to 194°F)
    FDT-47 “-HT”: NEMA 6 (IP67), PTFE, polyimide, Nickel-plated brass cord grip, PFA cable jacket
    Temperature: -40 to 176°C (-40 to 350°F)
Frequency:
    FDT-41 thru 46: 2 MHz
    FDT-47: 1 MHz
    FDT-48: 500 KHz
Cables: RG59 coaxial, 75 Ω or twin axial, 78 Ω (optional armored conduit)
Cable Length: Standard 6 m (20') [300 m (990') maximum in 3 m (10') increments; submersible conduit limited to 30 m (100') for transducers]
Software Utilities Utilized to configure, calibrate and troubleshoot flowmeters. Connection via USB A/B cable; software is compatible with Windows 2000, Windows XP, Windows Vista® and Windows® 7
RS485 Network All FDT-40 meters come equipped with RS485 drivers and utilize a MODBUS RTU command set (data can be returned in single-precision, doubleprecision, integer or floating point values). Up to 126 units products can be run on a single daisy-chain network and be individually queried for flow rate, positive flow accumulator, negative flow accumulator and signal strength. Flow accumulators can be cleared at discrete addresses or globally. The RS485 network is also compatible with direct to Excel, application.
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
Quick Ship
  
FDT-40E
TWD125,400
Availability: 4 weeks
 
Energy flowmeter display 95 to 264 Vac, temperature range 0 to 100°C (32 to 212°F)
Quick Ship
  
FDT-40E-VDC
TWD120,615
Availability: 4 weeks
 
Energy flowmeter display 10 to 28 Vdc, temperature range 0 to 100°C (32 to 212°F)
Quick Ship
  
FDT-40E-24VAC
TWD125,400
Availability: 4 weeks
 
Energy flowmeter display 24 Vac, temperature range 0 to 100°C (32 to 212°F)
Quick Ship
  
FDT-40E-HT
TWD125,400
Availability: 4 weeks
 
Energy flowmeter display 95 to 264 Vac, temperature range -40 to 177°C (-40 to 350°F)
Quick Ship
  
FDT-40E-VDC-HT
TWD120,615
Availability: 4 weeks
 
Energy flowmeter display 10 to 28 Vdc, temperature range -40 to 177°C (-40 to 350°F)
Quick Ship
  
FDT-40E-24VAC-HT
TWD125,400
Availability: 4 weeks
 
Energy flowmeter display 24 Vac, temperature range -40 to 177°C (-40 to 350°F)
Accessory Remote Transducers (Display Sold Separately)
Remote Transducers for ANSI Pipe (Display Sold Separately)
Quick Ship
  
FDT-41-ANSI
TWD23,715
Availability: 1 week
 
Transducer for 1/2" ANSI pipe
Quick Ship
  
FDT-42-ANSI
TWD23,715
Availability: 7 weeks
 
Transducer for 3/4" ANSI pipe
Quick Ship
  
FDT-43-ANSI
TWD25,735
Availability: 4 weeks
 
Transducer for 1" ANSI pipe
Quick Ship
  
FDT-44-ANSI
TWD25,735
Availability: 7 weeks
 
Transducer for 1 1/4" ANSI pipe
Quick Ship
  
FDT-45-ANSI
TWD25,735
Availability: 4 weeks
 
Transducer for 1 1/2" ANSI pipe
Quick Ship
FDT-46-ANSI
FDT-46-ANSI
TWD27,575
Availability: 5 weeks
 
Transducer for 2" ANSI pipe
Remote Transducers for Copper Pipe (Display Sold Separately)
Quick Ship
  
FDT-41-CP
TWD23,715
Availability: 7 weeks
 
Transducer for 1/2" Copper pipe
Quick Ship
  
FDT-42-CP
TWD23,715
Availability: 1 week
 
Transducer for 3/4" Copper pipe
Quick Ship
  
FDT-43-CP
TWD25,735
Availability: 4 weeks
 
Transducer for 1" Copper pipe
Quick Ship
  
FDT-44-CP
TWD25,735
Availability: 4 weeks
 
Transducer for 1 1/4" Copper pipe
Quick Ship
  
FDT-45-CP
TWD25,735
Availability: 7 weeks
 
Transducer for 1 1/2" Copper pipe
Quick Ship
  
FDT-46-CP
TWD27,575
Availability: 7 weeks
 
Transducer for 2" Copper pipe
Remote Transducers for Tubing (Display Sold Separately)
Quick Ship
  
FDT-41-TUBE
TWD23,715
Availability: 7 weeks
 
Transducer for 1/2" tubing
Quick Ship
  
FDT-42-TUBE
TWD23,715
Availability: 5 weeks
 
Transducer for 3/4" tubing
Quick Ship
  
FDT-43-TUBE
TWD25,735
Availability: 7 weeks
 
Transducer for 1" tubing
Quick Ship
  
FDT-44-TUBE
TWD25,735
Availability: 7 weeks
 
Transducer for 1 1/4" tubing
Quick Ship
  
FDT-45-TUBE
TWD25,735
Availability: 1 week
 
Transducer for 1 1/2" tubing
Quick Ship
  
FDT-46-TUBE
TWD27,575
Availability: 1 week
 
Transducer for 2" tubing
Remote Transducers (Display Sold Separately)
Quick Ship
FDT-47
FDT-47
TWD30,515
Availability: 1 week
 
Transducer for 2 to 24" pipe
Quick Ship
  
FDT-47-100FT
TWD38,980
Availability: 4 weeks
 
Transducer for 2 to 24" pipe with 100 ft of cable
Quick Ship
  
FDT-47-HT
TWD119,510
Availability: 7 weeks
 
High temperature transducer for 2 to 24" pipe
Quick Ship
  
FDT-47-HT-100FT
TWD127,970
Availability: 7 weeks
 
High temperature transducer for 2 to 24" pipe with 100 ft of cable
Quick Ship
  
FDT-48
TWD48,905
Availability: 7 weeks
 
Transducer for pipes over 24"
Quick Ship
  
FDT-48-100FT
TWD57,540
Availability: 7 weeks
 
Transducer for pipe over 24" with 100 ft of cable
Accessories
Quick Ship
  
FDT-40-PC-CABLE
TWD2,020
Availability: 4 weeks
 
Optional USB PC programming cable
Quick Ship
  
FDT-40-CABLE GLAND
TWD940
Availability: 1 week
 
Optional cable gland
Quick Ship
  
FDT-40-BHC
TWD2,480
Availability: 4 weeks
 
Brad Harrison connector for the FDT-40 Series
Quick Ship
  
FDT-40-RTDCONN
TWD2,940
Availability: 4 weeks
 
RTD Pig Tail (connection adapter)
Quick Ship
  
FDT-40-RTD1
TWD20,220
Availability: 4 weeks
 
RTD kit, clamp-on, 130C, 1000Ω 6.1 m (20')
Quick Ship
  
FDT-40-RTD2
TWD25,370
Availability: 1 week
 
RTD kit, clamp-on, 200C, 1000Ω 6.1 m (20')
Quick Ship
  
FDT-40-RTD3
TWD37,160
Availability: 1 week
 
RTD kit, insertion, 3 x 1/4", 126C, 1000Ω Platinum RTD
Quick Ship
FDT-GREASE
FDT-GREASE
TWD1,830
Availability: 1 week
 
Replacement acoustic couplant 150 g (5.3 oz)
Quick Ship
  
FDT-HT-GREASE
TWD4,520
Availability: 1 week
 
High temperature acoustic couplant 56 g (2 oz)
Quick Ship
FDT-NS-GREASE
FDT-NS-GREASE
TWD1,830
Availability: 7 weeks
 
Non-silicone acoustic couplant 79 g (2.8 oz)
All prices on this site are shown in Taiwan Dollars.
Note: Comes complete with operator’s manual. Transducers come with mounting gel.

Transducers sold separately.


Option Descriptions:


(1) Pipe and Tubing Sizes select from:
41 for 1/2 Inch
42 for 3/4 Inch
43 for 1 Inch
44 for 1 1/4 Inch
45 for 1 1/2 Inch
46 for 2 Inch
47 for 2 to 24 Inch
48 for Pipes over 24 inch

(2) Pipe and Tubing Material select from:
ANSI for ANSI pipe
CP for Copper pipe
TUBE for Plastic tubing

(3) High Temperature select from:
Nothing(leave field blank) for None
-HT for High temp transducers

(4) Cable Length select from:
Nothing(leave field blank) for Standard 6 m (20 feet)
-100FT for 30 m (100 feet)
Note: All combinations may not be valid, check spec sheet for valid part numbers.