Cart  |  Contact  |  Help  | 
Toll-Free in Taiwan: 0809 090 375
International+65 6415 5353

Positive Displacement Flowmeters

FPD2000 Series

Positive Displacement Flowmeters | FPD2000 Series

Positive Displacement Flowmeters

TWD82,740 FPD2004-A

  • Accuracy ±0.5% of Reading
  • Includes 3-point NIST certificate
  • Aluminum, 303 or 316 SS Bodies
  • Pressure Rating Up to 345 bar (5000 psi)
  • Pulse or mA Outputs Available
  • Bi-Directional Flow Capabilities
  • Economical Cost
Turbine, Paddle Wheel & Positive Displacement Flow Meters - View related products

Description

The FPD2000 Series represents a positive displacement meter that is affordable and accurate. One primary feature is the ability to maintain consistent accuracy despite changing viscosity conditions. This reliability, coupled with a large turndown range, offers an affordable replacement for older turbine technology. The meter’s solid construction and excellent dynamic response are well suited to the measurement of oil, grease, fuel, solvents, polyurethanes, brake fluid, skydrol as well as other nonabrasive lubricating fluids. Since there is no need for straight run piping upstream or downstream of the flow meter, the FPD2000 flow meters are simple to use and to install. The meters produce good resolution and high accuracy at low flow rates. Flow may be bidirectional, such as for cylinder position measurements, without damage to internal parts.

SPECIFICATIONS
Accuracy: ±0.5% over 10:1 turndown with 30cP fluid
Repeatability: ±0.1%
Max Fluid Temperature:
    Aluminum Body: Meter 85°C (185°F)
    Stainless Body: Meter 204°C (400°F)
Pressure Maximum: 345 bar (5000 psi)
Wetted Materials
Body:
    FPD2000 Series: Aluminum
    FPD2010 Series: 303 stainless steel
    FPD2020 Series: 316 stainless steel
Gear: Stainless steel
O-Ring: PTFE, FKM (optional)
Bearings: Stainless steel
Outputs
Temperature Range (Electronics):
    Standard Aluminum and Stainless Steel versions: -40 to 85°C (-40 to 185°F)
Square Wave: (Basic unit)
Supply Voltage: +10 to 28 Vdc
Supply Current: 8 mA @ 12 Vdc, 12 mA @ 24 Vdc
Duty Signal: 50% ±15%
Minimum Signal: 0.5 Hz
Frequency: Flow dependent, up to 2000 Hz
Driving Capacity: 50 mA max resistive load
Output Impedance: 40Ω - analog switch and self-resetting fuse
Analog Output (-A Models)
Supply Voltage: 10 to 30 Vdc
Output: 4 to 20 mA
Input: 0.25 Hz to 5 KHz
Amplitude: 1 Vp-p to 40 Vp-p
Update Time: 1/F + 25 msec
Linearity: ±0.01% of reading
Enclosure Rating: IP54
 
Model No. Pulses/Liter (Pulses/Gallon) Body Dia cm (inch) *Body Heightcm cm (inch) Filtration (microns)
FPD20X1 14,000 (53,000) 7.6 (3) 8.6 (3.4) 30
FPD20X2 4200 (15,900) 8.4 (3.3) 8.6 (3.4) 30
FPD20X3 1700 (6600) 8.4 (3.3) 8.6 (3.4) 30
FPD20X4 470 (1800) 12.4 (4.9) 13.8 (5.45) 30
FPD20X5 420 (1600) 21.3 (8.4) 17 (6.7) 200
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
ALUMINUM GEAR METERS WITH PULSE OUTPUT
  
FPD2001
TWD73,920
Availability: 4 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2002
TWD61,955
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2003
TWD68,650
Availability: 1 week
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2004
TWD78,925
Availability: 1 week
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
  
FPD2005
TWD146,390
Availability: 1 week
 
1¼ NPT, 1.9 to 227 LPM (0.5 to 60 GPM) Range
ALUMINUM GEAR METERS WITH 4 TO 20 mA OUTPUT
  
FPD2001-A
TWD79,260
Availability: 1 week
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2002-A
TWD69,120
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2003-A
TWD75,410
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2004-A
TWD82,740
Availability: 4 weeks
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
  
FPD2005-A
TWD162,745
Availability: 4 weeks
 
1¼ NPT, 1.9 to 227 LPM (0.5 to 60 GPM) Range
303 SS GEAR METERS WITH PULSE OUTPUT
  
FPD2011
TWD88,150
Availability: 4 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2012
TWD76,455
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2013
TWD90,650
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2014
TWD109,885
Availability: 1 week
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
  
FPD2015
TWD166,260
Availability: 4 weeks
 
1¼ NPT, 1.9 to 227 LPM (0.5 to 60 GPM) Range
303 SS GEAR METERS WITH PULSE OUTPUT AND OPTIONAL (-HT) FOR HIGH TEMPERATURE
  
FPD2011-HT
TWD92,340
Availability: 1 week
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2012-HT
TWD79,500
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2013-HT
TWD93,795
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2014-HT
TWD111,405
Availability: 1 week
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
  
FPD2015-HT
TWD154,565
Availability: 4 weeks
 
1¼ NPT, 1.9 to 227 LPM (0.5 to 60 GPM) Range
303 SS GEAR METERS WITH 4 TO 20 mA OUTPUT
  
FPD2011-A
TWD94,845
Availability: 2 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2012-A
TWD83,620
Availability: 1 week
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2013-A
TWD97,715
Availability: 1 week
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2014-A
TWD113,770
Availability: 4 weeks
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
  
FPD2015-A
TWD171,030
Availability: 4 weeks
 
1¼ NPT, 1.9 to 227 LPM (0.5 to 60 GPM) Range
303 SS GEAR METERS WITH 4 TO 20 mA OUTPUT AND OPTIONAL (-HT) HIGH TEMPERATURE
  
FPD2011-A-HT
TWD97,920
Availability: 4 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2012-A-HT
TWD88,420
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2013-A-HT
TWD102,550
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2014-A-HT
TWD116,440
Availability: 4 weeks
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
  
FPD2015-A-HT
TWD212,300
Availability: 4 weeks
 
1¼ NPT, 1.9 to 227 LPM (0.5 to 60 GPM) Range
316 SS GEAR METERS WITH PULSE OUTPUT
  
FPD2021
TWD99,675
Availability: 4 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2022
TWD88,085
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2023
TWD103,765
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2024
TWD131,720
Availability: 4 weeks
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
316 SS GEAR METERS WITH PULSE OUTPUT AND OPTIONAL -HT FOR HIGH TEMPERATURE
  
FPD2021-HT
TWD71,285
Availability: 4 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2022-HT
TWD91,765
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2023-HT
TWD107,520
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2024-HT
TWD132,970
Availability: 4 weeks
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
316 SS GEAR METERS WITH 4 TO 20 mA OUTPUT
  
FPD2021-A
TWD106,400
Availability: 4 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2022-A
TWD94,470
Availability: 1 week
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2023-A
TWD110,390
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2024-A
TWD135,435
Availability: 4 weeks
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
316 SS GEAR METERS WITH 4 TO 20 mA OUTPUT AND OPTIONAL -HT FOR HIGH TEMPERATURE
  
FPD2021-A-HT
TWD109,275
Availability: 4 weeks
 
1/4 NPT, 0.01 to 3 LPM (0.003 to 0.8 GPM) Range
  
FPD2022-A-HT
TWD99,170
Availability: 4 weeks
 
1/4 NPT, 0.04 to 7.5 LPM (0.01 to 2 GPM) Range
  
FPD2023-A-HT
TWD117,150
Availability: 4 weeks
 
1/2 NPT, 0.11 to 26.4 LPM (0.03 to 7 GPM) Range
  
FPD2024-A-HT
TWD140,135
Availability: 4 weeks
 
3/4 NPT, 0.19 to 75 LPM (0.05 to 20 GPM) Range
Accessories
DPF701
DPF701
Consult Sales  
Availability: 
 
 
Pulse input 6-digit panel meter for rate or total
  
FPD2000-CONNECTOR
TWD2,270
Availability: 4 weeks
 
6-pin connector for the FPD2000 Series with pulse output (Assembly and wire required)
  
FPD2000A-CONNECTOR
TWD2,475
Availability: 1 week
 
3-pin connector for the FPD2000-A Series with 4-20 mA output (Assembly and wire required)
All prices on this site are shown in Taiwan Dollars.
Note: Comes complete with operator's manual, connector, and K-Factor certificate,

Certificate does not include points and is not a NIST cert.

FPD2000, pulse output models come complete with the 6-pin FPD2000-CONNECTOR (Assembly and hook-up wire required).

FPD2000-A, 4-20 mA output models come complete with the 3-pin FPD2000A-CONNECTOR (Assembly and hook-up wire required).


Ordering Example:  (1) FPD2001 Aluminum gear meter with pulse output, 1/4 NPT connections and 0.003 to 0.8 GPM range, TWD73,920

Option Descriptions:


(1) Model & Range LPM (GPM) select from:
01 for Aluminum gear meter range 0.01 to 3 (0.003 to 0.8)
02 for Aluminum gear meter range 0.04 to 7.5 (0.01 to 2)
03 for Aluminum gear meter range 0.11 to 26.4 (0.03 to 7)
04 for Aluminum gear meter range 0.19 to 75 (0.05 to 20)
05 for Aluminum gear meter range 1.9 to 227 (0.5 to 60)
11 for 303 SS gear meter range 0.01 to 3 (0.003 to 0.8)
12 for 303 SS gear meter range 0.04 to 7.5 (0.01 to 2)
13 for 303 SS gear meter range 0.11 to 26.4 (0.03 to 7)
14 for 303 SS gear meter range 0.19 to 75 (0.05 to 20)
15 for 303 SS gear meter range 1.9 to 227 (0.5 to 60)
21 for 316 SS gear meter range 0.01 to 3 (0.003 to 0.8)
22 for 316 SS gear meter range 0.04 to 7.5 (0.01 to 2)
23 for 316 SS gear meter range 0.11 to 26.4 (0.03 to 7)
24 for 316 SS gear meter range 0.19 to 75 (0.05 to 20)

(2) Output select from:
Nothing(leave field blank) for Pulse output
-A for 4 to 20 mA output

(3) Additional Option select from:
Nothing(leave field blank) for None
-HT for High Temperature option on stainless steel models
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.