Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Taiwan: 0809 090 375
International+65 6415 5353

Industrial Electrodes

PHE-7151;ORE-7151;PHE-5312

Industrial Electrodes | PHE-7151;ORE-7151;PHE-5312

Industrial Electrodes

TWD6,998 PHE-7351-15

  • 16 Month Shelf Life
  • Rugged Contruction
  • Insertion/Submersion and In-Line Disposable Electrodes
Sensors - View related products

Description

Insertion/Submersion Combination Electrodes
The PHE-7151 series combination electrodes are ruggedly constructed; the outer body is ABS with 3/4" MNPT threads at both ends. The maximum insertion length is 31.75 mm/1.25". Electrodes are annular PTFE liquid junction refillable and include 15 ft of cable with a BNC connector. For applications with temperatures up to 120°C (248°F), units are available in polyphenylene sulfide (PPS).***

These electrodes have a special plunger design allowing them to be mounted at any angle.

Part No. Length
mm/in
Dia.
mm/in
pH
Range
Temp.
°C
Refill
or Gel
R (megohms)
at 25°C/77°F
Description
PHE-7151-15140/5.530/1.20 to 120 to 80Refill400Refillable general purpose**
PHE-7351-15140/5.530/1.20 to 120 to 80Gel400Sealed general purpose
PHE-7152-15140/5.530/1.20 to 140 to 80Refill1000Refillable high pH applications**
ORE-7151-15140/5.530/1.20 to 80RefillGeneral purpose refillable ORP**
** Refill Solution: PHFS-7151-4, 4 oz bottle; PHFS-7151-16, 16 oz bottle
***For polyphenylene sulfide body, add suffix “-PPS” to part number and $50 to price


In-Line Disposable Electrodes
In-line combination electrodes mount on standard pipe tees for continuous pH or ORP monitoring. The electrode is constructed in a PVDF housing with 1/2" MNPT threading. Probe insertion length is 25 mm (1") and is able to withstand pressure up to 150 psi. Three-meter (10-ft.) cable length and BNC connector are standard. Dimensions: 127 x 25 mm (5 x 10")

A

CPVC In-Line Disposable pH Electrodes
Also available, the CPVC In-Line Disposable Electrode is ruggedly constructed to withstand up to 100 psi. Probe insertion length is 51 mm (2") with 3/4" diameter. A 3/4" MNPT fitting is standard and is supplied with 3 m (10 ft.) of cable and a BNC connector. Dimensions: 168 x 25 mm (6.6 x 10")

B

  Part No. ph Range Temperature
Range °C/°F
Notes R Megohms
at 25°C/77°F
APHE-5311-100 to 135 to 100/23 to 212General purpose50
APHE-5312-100 to 140 to 100/32 to 212High pH200
APHE-5411-100 to 135 to 100/23 to 212Double junction50
APHE-5412-100 to 140 to 100/32 to 212Double junction high pH200
AORE-5311-10ORP5 to 100/23 to 212Platinum band
AORE-5411-10ORP5 to 100/23 to 212Platinum band double junction
AORE-5419-10ORP5 to 100/23 to 212Gold disc double junction
for cyanide applications
BPHE-5316-100 to 13-5 to 80/23 to 176Sealed Ag/AgCl50
Automatic Temperature Compensation is not required with ORP (Redox) electrodes.
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
Insertion/Submersion Combination Electrodes
Refillable General Purpose
  
PHE-7151-15
TWD7,933
Availability: 8 weeks
 
Refillable general purpose
  
PHE-7151-15-PT100
TWD10,325
Availability: 8 weeks
 
Refillable general purpose, with 100Ω Platinum RTD ATC
  
PHE-7151-15-PT1K
TWD10,323
Availability: 8 weeks
 
Refillable general purpose, with 1000Ω Platinum RTD ATC
  
PHE-7151-35
TWD11,300
Availability: 9 weeks
 
Refillable general purpose electrode with 10 m (35') of cable
  
PHE-7151-50
TWD13,070
Availability: 9 weeks
 
Refillable general purpose electrode with 15 m (50') of cable
Refillable High pH Applications
  
PHE-7152-15
TWD8,861
Availability: 8 weeks
 
Refillable high pH applications
  
PHE-7152-15-PT100
TWD11,300
Availability: 9 weeks
 
Refillable high pH applications, with 100Ω Platinum RTD ATC
  
PHE-7152-15-PT1K
TWD11,300
Availability: 9 weeks
 
Refillable high pH applications, with 1000Ω Platinum RTD ATC
  
PHE-7152-25
TWD11,300
Availability: 9 weeks
 
Refillable high pH accplications with 7.6 m (25') of cable
  
PHE-7152-30-PT100
TWD14,620
Availability: 9 weeks
 
Refillable high pH applications with 9 m (30') of cable and 100Ω Platinum RTD
  
PHE-7152-50
TWD14,180
Availability: 9 weeks
 
Refillable high pH accplications with 15 m (50') of cable
  
PHE-7152-50-PT1K
TWD16,395
Availability: 9 weeks
 
Refillable high pH applications with 15 m (50') of cable and 1000Ω Platinum RTD
Sealed General Purpose
PHE-7351-15
PHE-7351-15
TWD6,998
Availability: 2 weeks
 
Sealed general purpose
  
PHE-7351-15-HF
TWD9,950
Availability: 8 weeks
 
Sealed general purpose sensor, fluoride resistant
  
PHE-7351-15-PPS
TWD9,130
Availability: 9 weeks
 
Sealed general purpose sensor with polyphenylene sulfide body
  
PHE-7351-15-PT100
TWD9,950
Availability: 8 weeks
 
Sealed general purpose, with 100Ω Platinum RTD ATC
  
PHE-7351-15-PT100-PPS
TWD11,640
Availability: 9 weeks
 
Sealed general purpose, with 100Ω Platinum RTD ATC and polyphenylene sulfide body
  
PHE-7351-15-PT1K
TWD9,950
Availability: 8 weeks
 
Sealed general purpose, with 1000Ω Platinum RTD ATC
  
PHE-7351-25
TWD9,950
Availability: 8 weeks
 
Sealed general purpose with 7.6 m (25') of cable
  
PHE-7351-30-PT100
TWD13,010
Availability: 9 weeks
 
Sealed general purpose, with 100Ω Platinum RTD ATC and 9 m (30') of cable
  
PHE-7351-40
TWD11,365
Availability: 9 weeks
 
Sealed general purpose with 12 m (40') of cable
Oxidation Reduction Potential
  
ORE-7151-15
TWD10,105
Availability: 9 weeks
 
General purpose refillable ORP
PHE-7000 Series Accessories
  
PHEH-71-4
TWD2,290
Availability: 9 weeks
 
48 inch extension for above electrodes with ABS bodies
In-Line Disposable Electrodes
  
PHE-5311-10
TWD6,025
Availability: 6 weeks
 
General purpose
  
PHE-5311-10-EB
TWD9,085
Availability: 6 weeks
 
Pre-amplified general purpose sensor with replaceable external battery pack
  
PHE-5311-10-NB
TWD8,475
Availability: 6 weeks
 
Pre-amplified general purpose sensor requires external DC power supply of ±1.5 Vdc to ±9 Vdc
  
PHE-5311-10-PB
Consult Sales  
Availability: 
 
 
Pre-amplified general purpose sensor with battery encapsulated in the cap of the electrode. Battery life is approximately 1 year and is not replaceable
  
PHE-5311-10-PT100
Consult Sales  
Availability: 
 
 
General purpose, with 100Ω Platinum RTD ATC
  
PHE-5311-10-PT1K
TWD8,475
Availability: 6 weeks
 
General purpose, with 1000Ω Platinum RTD ATC
  
PHE-5312-10
TWD5,787
Availability: 6 weeks
 
High pH
  
PHE-5312-10-PT100
Consult Sales  
Availability: 
 
 
High pH, with 100Ω Platinum RTD ATC
  
PHE-5411-10
TWD7,300
Availability: 6 weeks
 
Double junction
  
PHE-5411-10-EB
Consult Sales  
Availability: 
 
 
Pre-amplified double junction sensor with replaceable external battery pack
  
PHE-5411-10-NB
TWD9,650
Availability: 6 weeks
 
Pre-amplified double junction sensor requires external DC power supply of ±1.5 Vdc to ±9 Vdc
  
PHE-5411-10-PT1K
TWD9,650
Availability: 6 weeks
 
Double junction, with 1000Ω Platinum RTD ATC
  
PHE-5412-10
TWD6,782
Availability: 6 weeks
 
Double junction high pH
  
ORE-5311-10
TWD6,205
Availability: 6 weeks
 
Platinum band
  
ORE-5411-10
TWD6,870
Availability: 6 weeks
 
Platinum band double junction
  
ORE-5419-10
Consult Sales  
Availability: 
 
 
Gold disc double junction for cyanide applications
CPVC In-Line Disposable pH Electrode
  
PHE-5316-10
TWD5,415
Availability: 6 weeks
 
Sealed Ag/AgCl CPVC electrode
  
PHE-5316-10-PT100
TWD7,865
Availability: 6 weeks
 
Sealed Ag/AgCl CPVC electrode, with 100Ω Platinum RTD ATC
  
PHE-5316-10-PT1K
TWD7,865
Availability: 6 weeks
 
Sealed Ag/AgCl CPVC electrode, with 1000Ω Platinum RTD ATC
Refill Solutions
  
PHFS-7151-4
TWD1,380
Availability: 8 weeks
 
4 oz bottle
  
PHFS-7151-16
TWD1,665
Availability: 9 weeks
 
16 oz bottle
Heavy Duty Extension Cables for Industrial Electrodes
  
PHEC-B10HD
TWD2,562
Availability: 4 weeks
 
BNC to BNC extension cable 10 feet
  
PHEC-B25HD
TWD3,710
Availability: 5 weeks
 
BNC to BNC extension cable 25 feet
PHEC-B50HD
PHEC-B50HD
Consult Sales  
Availability: 
 
 
BNC to BNC extension cable 50 feet
Accessories
  
EB-SPARE
TWD1,085
Availability: 7 weeks
 
Replacement battery pack for electrodes with "-EB" power option
  
PHE-DPS
TWD2,840
Availability: 6 weeks
 
±3 Vdc power supply to operate preamplified electrodes, input 115 Vac
Solutions for all pH Electrodes
PHA-10
PHA-10
TWD660
Availability: 2 weeks
 
pH 10 buffer solution, 500 ml (1 pt)
PHA-10-GAL
PHA-10-GAL
TWD1,645
Availability: 1 week
 
pH 10 buffer solution, 4L (1 gal)
PHA-4
PHA-4
TWD625
Availability: 2 weeks
 
pH 4 buffer solution, 500 ml (1 pt)
PHA-4-GAL
PHA-4-GAL
TWD1,557
Availability: 2 weeks
 
pH 4 buffer solution, 4L (1 gal)
PHA-7
PHA-7
TWD625
Availability: 1 week
 
pH 7 buffer solution, 500 ml (1 pt)
PHA-7-GAL
PHA-7-GAL
TWD1,557
Availability: 1 week
 
pH 7 buffer solution, 4L (1 gal)
PHA-DI
PHA-DI
TWD734
Availability: 1 week
 
De-ionized water, 500 ml (1 pt)
PHA-DI-GAL
PHA-DI-GAL
TWD1,841
Availability: 1 week
 
De-ionized water, 4L (1 gal)
  
PHAB-DI
TWD1,670
Availability: 3 weeks
 
20 single use foil packets of de-ionized water
PHAB-PH
PHAB-PH
TWD1,669
Availability: 1 week
 
5 each single use foil packets of pH-4, pH-7, pH-10, and de-ionized water
All prices on this site are shown in Taiwan Dollars.
Note: PHE-7000 Series Combination Electrodes come complete with 4.5 m (15') of cable with BNC connector and electrode care instruction sheet.

PHE-5000 Series In-Line Disposable Electrodes come complete with 3 m (10') of cable with BNC connector and electrode care instruction sheet.

For non-standard cable lengths replace the "(-15) for the PHE-7000 Series or the "(-10)" for the PHE-5000 Series with the required cable length in feet; add $2 per foot to the price. (Additional per foot cost applies to the entire length of cable).

Automatic temperature compensation is not required with ORP electrodes.


Options for the PHE-7000 Series:

For HF/Fluoride Resistant electrode, add suffix "-HF" to model number, add $50 to price.

For polyphenylene sulfide body add suffix "-PPS" to model number; add $50 to price.

For high temperature reference cells, add suffix "-HT" to the model number, add $35 to price.

Note: "-PPS" and "-HT" options only available on the PHE-7351 and "-HT" option is only available in combination with PPS option on the PHE-7351 electrode.

For 100O Platinum RTD Automatic Temperature Compensation (ATC), add suffix "-PT100" to the model number, add $50 to price.

For 1000O Platinum RTD Automatic Temperature Compensation (ATC), add suffix "-PT1K" to model number, add $50 to price.


Option Descriptions:


(1) Refill or Gel and Notes select from:
71 for Refill
73 for Gel
53 for General purpose
53 for High pH
54 for Double junction high pH
54 for Platinum band
53 for Sealed Ag/AgCl

(2) PH Range and RM OHM at 25°C (77°F) select from:
51 for 0 to 12 (7100 Series)
52 for 0 to 14 (7300 Series)
11 for 0 to 13 RM OHM at 25°C (77°F) 50 (5300 Series)
12 for 0 to 14 RM OHM at 25°C (77°F) 200 (5400 Series)
16 for 0 to 13 RM OHM at 25°C (77°F) 50 (5300 Series)

(3) Cable Length select from:
15 for 15 Feet
25 for 25 Feet
50 for 50 Feet

(4) RTD select from:
Nothing(leave field blank) for None
-PT100 for 100 OHM Platinum RTD Automatic Temperature Compensation (ATC)
-PT1K for 1000 OHM Platinum RTD Automatic Temperature Compensation (ATC)

(5) Additional Option select from:
Nothing(leave field blank) for None
-HF for HF/Fluoride Resistant electrode
-PPS for Polyphenylene sulfide body
-HT for High temperature reference cells
-PPS-HT for Polyphenylene sulfide body and High temperature reference cells
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.