Electronically Controlled Proportional Valves Using Solenoid Technology

PV100 Series

Electronically Controlled Proportional Valves Using Solenoid Technology, Gases Only, Low-cost | PV100 Series

TWD30,515 PV101-MA

CE
  • Low Power Consumption
  • 100 msec Response Time at Maximum Pressure
  • Stainless Steel Wetted Parts with FKM Seals
  • 12 to 24 Vdc Power
  • For Clean, Dry, Non-Corrosive Gases
Valves - View related products

Description

The PV100 Series comprises economical proportional valves for use with gases. They combine a solenoid valve with an electronics package that digitally modulates the control signal to provide analog proportional control without the expense or complexity of stepper motors, servo valves, or other proportioning devices. The PV100 Series can be used in open- or closed-loop systems to control flow, pressure, temperature, speed, or position parameters of gases.

SPECIFICATIONS
Valve Type: 2-way normally closed
Wetted Parts: Stainless steel with FKM seals
Power: 12 to 24 Vdc
Power Consumption: 7 W maximum
Control Signals: 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA DC (specify when ordering)
Ambient Temperature Range: -10 to 50°C (14 to 122°F) media temperature
Range: -18 to 82°C (0 to 180°F)
Linear Control Range: 15 to 85% of full flow
Response Time for Complete Cycle (Off-Fully Open-Off): 40 ms @ 0 pressure; 100 ms @ max pressure
Repeatability: ±5% when in operating linear control range
Electrical Connection: 0.4 m (18") color-coded lead wires
Wiring:
   Red: DC power supply
   Gray: Control signal (+)
   Black: Common (to power and control)
Pressure Connections: 1/8 FNPT
Enclosure: General purpose, NEMA 11
(Specify Model Number)
Part Number/Desc.
Qty
Description
PV101 Models with 1/32' orifice, 0.02 Cv, 200 psi max pressure
PV101-5V
TWD31,000
Availability: 16 weeks
 
0 to 50,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV101-10V
TWD31,802
Availability: 18 weeks
 
0 to 50,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV101-MA
TWD30,515
Availability: 16 weeks
 
0 to 50,000 SCCM flow at max pressure, 4 to 20 mA control signal
PV102 Models with 3/64' orifice, 0.045 Cv, 100 psi max pressure
PV102-5V
TWD27,370
Availability: 16 weeks
 
0 to 65,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV102-10V
TWD30,440
Availability: 16 weeks
 
0 to 65,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV102-MA
TWD30,735
Availability: 16 weeks
 
0 to 65,000 SCCM flow at max pressure, 4 to 20 mA control signal
PV103 Models with 1/16' orifice, 0.08 Cv, 60 psi max pressure
PV103-5V
TWD27,985
Availability: 16 weeks
 
0 to 75,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV103-10V
TWD30,984
Availability: 18 weeks
 
0 to 75,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV103-MA
TWD27,370
Availability: 16 weeks
 
0 to 75,000 SCCM flow at max pressure, 4 to 20 mA control signal
PV104 Models with 5/64' orifice, 0.12 Cv, 40 psi max pressure
PV104-5V
TWD30,695
Availability: 16 weeks
 
0 to 80,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV104-10V
TWD31,485
Availability: 18 weeks
 
0 to 80,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV104-MA
TWD29,365
Availability: 16 weeks
 
0 to 80,000 SCCM flow at max pressure, 4 to 20 mA control signal
All prices on this site are shown in Taiwan Dollars.
Note: Comes with complete operator’s manual.
Ordering Example: (1) PV101-MA Proportional valve with 1/32'' orifice, 200 psi max. pressure and 4-20mA control signal, TWD30,515