Electronically Controlled Proportional Valves Using Solenoid Technology

PV100 Series

Electronically Controlled Proportional Valves Using Solenoid Technology, Gases Only, Low-cost | PV100 Series

TWD27,450 PV101-MA

CE
  • Low Power Consumption
  • 100 msec Response Time at Maximum Pressure
  • Stainless Steel Wetted Parts with FKM Seals
  • 12 to 24 Vdc Power
  • For Clean, Dry, Non-Corrosive Gases
Valves - View related products

Description

The PV100 Series comprises economical proportional valves for use with gases. They combine a solenoid valve with an electronics package that digitally modulates the control signal to provide analog proportional control without the expense or complexity of stepper motors, servo valves, or other proportioning devices. The PV100 Series can be used in open- or closed-loop systems to control flow, pressure, temperature, speed, or position parameters of gases.

SPECIFICATIONS
Valve Type: 2-way normally closed
Wetted Parts: Stainless steel with FKM seals
Power: 12 to 24 Vdc
Power Consumption: 7 W maximum
Control Signals: 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA DC (specify when ordering)
Ambient Temperature Range: -10 to 50°C (14 to 122°F) media temperature
Range: -18 to 82°C (0 to 180°F)
Linear Control Range: 15 to 85% of full flow
Response Time for Complete Cycle (Off-Fully Open-Off): 40 ms @ 0 pressure; 100 ms @ max pressure
Repeatability: ±5% when in operating linear control range
Electrical Connection: 0.4 m (18") color-coded lead wires
Wiring:
   Red: DC power supply
   Gray: Control signal (+)
   Black: Common (to power and control)
Pressure Connections: 1/8 FNPT
Enclosure: General purpose, NEMA 11
(Specify Model Number)
Part Number/Desc.
Qty
Description
PV101 Models with 1/32' orifice, 0.02 Cv, 200 psi max pressure
PV101-5V
TWD27,885
Availability: 11 weeks
 
0 to 50,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV101-10V
TWD28,604
Availability: 13 weeks
 
0 to 50,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV101-MA
TWD27,450
Availability: 11 weeks
 
0 to 50,000 SCCM flow at max pressure, 4 to 20 mA control signal
PV102 Models with 3/64' orifice, 0.045 Cv, 100 psi max pressure
PV102-5V
TWD24,615
Availability: 11 weeks
 
0 to 65,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV102-10V
TWD27,380
Availability: 11 weeks
 
0 to 65,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV102-MA
TWD27,645
Availability: 11 weeks
 
0 to 65,000 SCCM flow at max pressure, 4 to 20 mA control signal
PV103 Models with 1/16' orifice, 0.08 Cv, 60 psi max pressure
PV103-5V
TWD25,170
Availability: 11 weeks
 
0 to 75,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV103-10V
TWD27,868
Availability: 13 weeks
 
0 to 75,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV103-MA
TWD24,615
Availability: 11 weeks
 
0 to 75,000 SCCM flow at max pressure, 4 to 20 mA control signal
PV104 Models with 5/64' orifice, 0.12 Cv, 40 psi max pressure
PV104-5V
TWD27,610
Availability: 11 weeks
 
0 to 80,000 SCCM flow at max pressure, 0 to 5 Vdc control signal
PV104-10V
TWD28,320
Availability: 13 weeks
 
0 to 80,000 SCCM flow at max pressure, 0 to 10 Vdc control signal
PV104-MA
TWD26,415
Availability: 11 weeks
 
0 to 80,000 SCCM flow at max pressure, 4 to 20 mA control signal
All prices on this site are shown in Taiwan Dollars.
Note: Comes with complete operator’s manual.
Ordering Example: (1) PV101-MA Proportional valve with 1/32'' orifice, 200 psi max. pressure and 4-20mA control signal, TWD27,450