Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Taiwan: 0809 090 375
International+65 6415 5353

Wet/Wet Differential Pressure Transmitters

PX409-WWDIFF

Wet/Wet Differential Pressure Transducer and Pressure Transmitters
PX409 Series | PX409-WWDIFF

TWD43,594 PX409-015DWUV

CE
  • FAST DELIVERY!
  • Precision Micro-Machined Silicon Core
  • 5-Point NIST Traceable Calibration
  • High Stability, Low Drift
  • Welded Stainless Steel Construction
  • 316L SS Wetted Parts
  • Now Available with M12 Connector,
    Order Model PX459

    (See Part Number Builder at bottom of page)
  • Premium Temperature Performance
  • Broad Compensated Temperature Range
  • Durable, 1 Million Cycle Life
  • Ruggedized with Secondary Containment
  • Customized Specifications Available
Pressure Transducers - View related products

Description

Get all the great performance characteristics of the Micro-Machined Silicon Transducers in these wet/wet differential pressure models. These rugged stainless steel transducers are ideal for tough industrial automotive, or aerospace applications requiring a wet/wet transducer. They can be used in test benches, fitler monitoring, hydraulic, flow, or water/wastewater applications, as well as factory or pneumatic air, pitot tubes, air speed and other industrial or aerospace applications. The solid state silicon core and all stainless steel wetted parts will provide long, reliable service life with excellent long term stability.

COMMON SPECIFICATIONS
Accuracy: 0.08% BSL linearity, hysteresis and repeatability combined
Minimum Resistance Between Transducer Body and Any Wire: 100 MΩ
Operating Temperature:
    mV/V and 5 to 10 Vdc Output: -45 to 121°C (-49 to 250°F)
    mA Output: -45 to 115°C (-49 to 239°F)
Compensated Temperature Range:
    10 inH2O to 5 psi: -17 to 85°C (1 to 185°F)
    15 to 1000 psi: -29 to 85°C (-20 to 185°F)
Thermal Accuracy:       Zero     Span
% Span Shift over compensated temperature range
    10 inH20 to 5 psi:  ±1.00%    ±1.00%
    15 to 1000 psi:      ±0.50%    ±0.50%
Pressure Cycles: 1 million minimum
Long Term Stability (1-Year): ±0.1% FS typical
Bandwidth: DC to 1 kHz typical
Response Time: <1 ms
CE Complient: Meets EN61326-1: 2006 for industrial locations
Shock: 50 g, 11 ms, half-sine, vertical and horizontal axis
Vibration: 5-2000-5 Hz 30 minute cycle, Curve L Mil-Spec 810 figure 514-2-2, horizontal and vertical axis
Wetted Parts: 316L stainless steel
Line/Static Pressure: 500 psi max applied to both sides simultaneously
Proof Pressure (Differential):
    10 inH2O range = 10 times range
    1 psi range = 6 times range
    2.5 to 750 psi ranges = 4 times range
    1000 psi range = 3 times range
Hi Side Containment Pressure (Differential):
    Ranges 10 inH2O to 5 psi: to 1000 psi
    Ranges 15 to 1000 psi: to 3000 psi
Pressure Ports: ¼NPT male
Electrical Terminations:
    PX409: 2 m (6') cable
    PX409C: 2 m (6') cable with ½ NPT conduit thread
    PX419: Mini-DIN (mating connector included)
    PX429: Twist-lock, mating connector (sold separately)
    PX459: M12 Connector, mating connector (sold separately)
    Mating Connector for PX429: PT06F10-6S
Weight: 200 g (7 oz) max

UNI-DIRECTIONAL mV/V SPECIFICATIONS
Output: 10 mV/V ratiometric
Supply Voltage: 5 to 10 Vdc
Current Draw: 5 mA @ 10 Vdc
Input Impedance: 1000 to 5000 Ω
Output Impedance: 5000 Ω ±10% typical
Zero Balance:
    Ranges ≤ 1psi: ±1% typ (2% max)
    Ranges > 1psi: ±0.5% typ (1% max)
Span Setting:
    Ranges ≤ 1psi: ±1% typ (2% max)
    Ranges > 1psi: ±0.5% typ (1% max)

UNI-DIRECTIONAL VOLTAGE OUTPUT SPECIFICATIONS
Output Voltage/Supply Voltage: 0 to 5 Vdc/ 10 to 30 Vdc; 0 to 10 Vdc/15 to 30 Vdc (change "5V" to "10V" in model number)
Current Draw: 10 mA max
Maximum Current Output: 2 mA (= 2500 Ω min load resistance)
Output Impedance: 100 Ω
Zero Balance:
    Ranges > 1psi: ±0.5% typ (1% max)
    Ranges ≤ 1psi: ±1% typ (2% max)
Span Setting:
    Ranges > 1psi: ±0.5% typ (1% max)
    Ranges ≤ 1psi: ±1% typ (2% max)

UNI-DIRECTIONAL mA SPECIFICATIONS
Output: 4 to 20 mA
Supply Voltage: 9 to 30 Vdc; [9 to 20 Vdc above 105°C (229°F)]
Max Loop Resistance: (Vs-9) x 50 Ω
Zero Balance:
    Ranges > 1psi: ±0.5% typ (1% max)
    Ranges ≤ 1psi: ±1% typ (2% max)
Span Setting:
    Ranges > 1psi: ±0.5% typ (1% max)
    Ranges ≤ 1psi: ±1% typ (2% max)

Four Termination Styles are available:
PX409 = 2 m (6ft) cable
PX419 = mini-DIN connector
PX429 = Twist-Lock connector
PX459 = M12 connector

(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
10 mV/V Output - 2 m (6') Cable Electrical Termination
  
PX409-10WDWUV
TWD46,700
Availability: 7 weeks
 
Wet/Wet 10 inH2O differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-001DWUV
TWD46,960
Availability: 7 weeks
 
Wet/Wet 1 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-2.5DWUV
TWD46,700
Availability: 7 weeks
 
Wet/Wet 2.5 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-005DWUV
TWD43,594
Availability: 3 weeks
 
Wet/Wet 5 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-015DWUV
TWD43,594
Availability: 3 weeks
 
Wet/Wet 15 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-030DWUV
TWD43,595
Availability: 7 weeks
 
Wet/Wet 30 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-050DWUV
TWD43,355
Availability: 3 weeks
 
Wet/Wet 50 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-100DWUV
TWD43,595
Availability: 7 weeks
 
Wet/Wet 100 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-150DWUV
TWD43,355
Availability: 7 weeks
 
Wet/Wet 150 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-250DWUV
TWD43,355
Availability: 7 weeks
 
Wet/Wet 250 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-500DWUV
TWD43,355
Availability: 7 weeks
 
Wet/Wet 500 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-750DWUV
TWD43,355
Availability: 7 weeks
 
Wet/Wet 750 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
  
PX409-1.0KDWUV
TWD43,595
Availability: 7 weeks
 
Wet/Wet 1000 psi differential pressure range, 10 mV/V output, 2 m (6ft) cable termination
0 to 5 Vdc Output - 2 m (6') Cable Electrical Termination
  
PX409-10WDWU5V
TWD50,286
Availability: 1 week
 
Wet/Wet 10 inH2O differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-001DWU5V
TWD50,286
Availability: 7 weeks
 
Wet/Wet 1 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-2.5DWU5V
TWD50,286
Availability: 7 weeks
 
Wet/Wet 2.5 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-005DWU5V
TWD47,689
Availability: 3 weeks
 
Wet/Wet 5 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-015DWU5V
TWD47,689
Availability: 3 weeks
 
Wet/Wet 15 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-030DWU5V
TWD47,689
Availability: 7 weeks
 
Wet/Wet 30 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-050DWU5V
TWD45,140
Availability: 3 weeks
 
Wet/Wet 50 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-100DWU5V
TWD47,690
Availability: 7 weeks
 
Wet/Wet 100 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-150DWU5V
TWD47,689
Availability: 7 weeks
 
Wet/Wet 150 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-250DWU5V
TWD47,425
Availability: 7 weeks
 
Wet/Wet 250 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-500DWU5V
TWD47,689
Availability: 7 weeks
 
Wet/Wet 500 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-750DWU5V
TWD47,425
Availability: 7 weeks
 
Wet/Wet 750 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
  
PX409-1.0KDWU5V
TWD47,425
Availability: 7 weeks
 
Wet/Wet 1000 psi differential pressure range, 0 to 5 Vdc output, 2 m (6ft) cable termination
4 to 20 mA Output - 2 m (6') Cable Electrical Termination
  
PX409-10WDWUI
TWD50,290
Availability: 1 week
 
Wet/Wet 10 inH2O differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-001DWUI
TWD47,599
Availability: 7 weeks
 
Wet/Wet 1 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-2.5DWUI
TWD50,290
Availability: 7 weeks
 
Wet/Wet 2.5 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-005DWUI
TWD45,140
Availability: 3 weeks
 
Wet/Wet 5 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-015DWUI
TWD45,140
Availability: 3 weeks
 
Wet/Wet 15 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-030DWUI
TWD47,689
Availability: 7 weeks
 
Wet/Wet 30 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-050DWUI
TWD47,690
Availability: 3 weeks
 
Wet/Wet 50 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-100DWUI
TWD47,689
Availability: 7 weeks
 
Wet/Wet 100 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-150DWUI
TWD47,425
Availability: 7 weeks
 
Wet/Wet 150 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-250DWUI
TWD45,140
Availability: 7 weeks
 
Wet/Wet 250 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-500DWUI
TWD47,690
Availability: 7 weeks
 
Wet/Wet 500 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-750DWUI
TWD47,425
Availability: 7 weeks
 
Wet/Wet 750 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
  
PX409-1.0KDWUI
TWD47,425
Availability: 7 weeks
 
Wet/Wet 1000 psi differential pressure range, 4 to 20 mA output, 2 m (6ft) cable termination
ACCESSORIES
PT06F10-6S
PT06F10-6S
TWD1,394
Availability: 1 week
 
Mating connector for PX419 (sold separately)
DP25B-S
DP25B-S
TWD15,095
Availability: 2 weeks
 
4-Digit strain meter for mV/V output models
DP25B-E
DP25B-E
TWD15,943
Availability: 2 weeks
 
4-Digit process meter for voltage and current output models
DP41-S
DP41-S
TWD32,325
Availability: 2 weeks
 
6-Digit strain meter for mV/V models
DP41-E
DP41-E
TWD34,150
Availability: 2 weeks
 
6-Digit process meter for voltage and current models
All prices on this site are shown in Taiwan Dollars.
Note: To order models with different electrical terminations, change model number to on of the following:
PX409 = Cable Connection (featured in chart above)
PX419 = mini-DIN Connection (mating connector provided)
PX429 = Twist Lock Connector (mating connector sold separately)

EXTRA HIGH ACCURACY MODELS ((available only on >5 psi models)
For Extra High 0.05% Accuracy Models add suffix "-EH", add $100
For Extreme 0.03% Linearity Models add suffix "-XL", add $200
(Options are mutually exclusive)

Additional Ranges Available
See Part Number Builder (below) for the full selection of pressure ranges
Ordering Example: (1) PT06F10-6S Mating twist-lock connector (sold separately), TWD1,394  plus (1) PX429-005DWU5V Wet/Wet 5 psi diff. pres. range, 0 to 5 Vdc output, twist-lock termination, TWD45,140, TWD1,394 + 45,140 = TWD46,534

Option Descriptions:


(1) Electrical Termination select from:
PX409 for 2 m (6') cable
PX419 for mini-DIN
PX429 for Twist-Lock (mating connector sold separately)
PX459 for M12 Connector (mating connector sold separately)

(2) Pressure Range (PSI) select from:
10W for 0-10 inH2O
001 for 1 psi
2.5 for 2.5 psi
005 for 0-5 psi
015 for 0-15 psi
030 for 0-30 psi
050 for 0-50 psi
100 for 0-100 psi
150 for 0-150 psi
250 for 0-250 psi
500 for 0-500 psi
750 for 0-750 psi
1.0K for 0-1000 psi

(3) Units select from:
DWU for Wet/Wet Differential Pressure
DDU for Wet/Dry Differential Pressure

(4) Output select from:
V for 10 mV/V Output
5V for 0-5 Volt dc Output
10V for 0-10 Volt dc Output
I for 4-20 mA Output

(5) Options (available only on models greater than 5 psi - these options are mutually exclusive) select from:
for
-EH for Extra High (0.05%) Accuracy add $100
-XL for Extreme (0.03%) Linearity add $200
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.