Cart  |  Contact  |  Help  |  info@sea.omega.com  | 
Toll-Free in Taiwan: 0809 090 375
International+65 6415 5353

Thermocouple Wire Type J, Duplex Insulated

J Type Thermocouple Wire

Tupe J Thermocouple Wire, various insulation's available online | J Type Thermocouple Wire

TWD2,654 TT-J-20-50

  • High Quality Type "J" Thermocouple Grade Wire
  • In Stock - Available for Immediate Shipment
  • Choice of Insulation, Wire Gage, & Length
Wire: Thermocouple, RTD, Thermistor and Hook-Up - View related products

Description

ANSI Color Code T type thermocouple wire: Positive Wire, White; Negative Wire, Red; Overall, Brown

The "To Order" box contains some examples of popular models. Use the "Part Number Builder" (Below Table) to get pricing for all available models. Use the table below as a guide for types available

 Insulation AWG
No.
Model
Number
Type
Wire
Insulation Max. Temp Nominal
Size
Wt.†
 lb/1000'
Conductor Overall °F °C
Ceramic* 14 XC-J-14 Solid Nextel Ceramic Nextel Ceramic 1100 590 .140 x .200 38
20 XC-J-20 Solid Nextel Ceramic Nextel Ceramic 900 480 .135 x .190 16
20 XT-J-20 Solid Nextel Ceramic Nextel Ceramic 900 480 .105 x .155 15
20 XL-J-20 Solid Nextel Ceramic Nextel Ceramic 900 480 .095 x .135 14
24 XC-J-24 Solid Nextel Ceramic Nextel Ceramic 700 370 .115 x .175 12
24 XT-J-24 Solid Nextel Ceramic Nextel Ceramic 700 370 .088 x .132 11
24 XL-J-24 Solid Nextel Ceramic Nextel Ceramic 700 370 .078 x .116 10

Silica*
14 XS-J-14 Solid Silica Silica 1100 590 .140 x .200 35
20 XS-J-20 Solid Silica Silica 900 480 .105 x .155 12
24 XS-J-24 Solid Silica Silica 700 370 .088 x .132 10
High
Temp.
Glass**
20 HH-J-20 Solid High Temp. Glass High Temp. Glass 900 480 .060 x .105 9
24 HH-J-24 Solid High Temp. Glass High Temp. Glass 700 370 .055 x .090 5
Glass 14 GG-J-14 Solid Glass Braid Glass Braid 900 482 .100 x .160 43
20 GG-J-20 Solid Glass Braid Glass Braid 900 482 .060 x .095 9
20 GG-J-20S 7 x 28 Glass Braid Glass Braid 900 482 .060 x .100 9
24 GG-J-24 Solid Glass Braid Glass Braid 700 370 .050 x .080 5
24 GG-J-24S 7 x 32 Glass Braid Glass Braid 700 370 .050 x .085 5
28 GG-J-28 Solid Glass Wrap Glass Braid 700 370 .045 x .070 3
30 GG-J-30 Solid Glass Wrap Glass Braid 600 320 .045 x .070 3
36 GG-J-36 Solid Glass Wrap Glass Braid 600 320 .045 x .070 2
Glass with Stainless
Steel Overbraid
20 GG-J-20-SB Solid Glass SS Braid over Glass 900 482 .090 x .120 14
20S GG-J-20S-SB 7 x 28 Glass SS Braid over Glass 900 482 .090 x .127 15
24 GG-J-24-SB Solid Glass SS Braid over Glass 900 482 .085 x .117 11
24S GG-J-24S-SB 7 x 32 Glass SS Braid over Glass 900 482 .080 x .110 11
Kapton Fused
Polymide Tape
20 KK-J-20 Solid Fused Polymide Tape Fused Polymide Tape 500 260 .060 x .100 11
20S KK-J-20S 7 x 28 Fused Polymide Tape Fused Polymide Tape 500 260 .060 x .105 11
24 KK-J-24 Solid Fused Polymide Tape Fused Polymide Tape 500 260 .050 x .075 6
24S KK-J-24S 7 x 32 Fused Polymide Tape Fused Polymide Tape 500 260 .050 x .085 6
30 KK-J-30 Solid Fused Polymide Tape Fused Polymide Tape 500 260 .040 x .055 5
PFA
and
Glass 
30 TG-J-30 Solid PFA Glass Braid 500 260 .034 x .047 2
36 TG-J-36 Solid PFA Glass Braid 500 260 .028 x .038 2
40 TG-J-40 Solid PFA Glass Braid 500 260 .026 x .035 2

Neoflon
PFA
(HighPerformance) 
20 TT-J-20 Solid PFA PFA 500 260 .068 x .116 11
20 TT-J-20S 7 x 28 PFA PFA 500 260 .073 x .126 11
22 TT-J-22S 7 x 30 PFA PFA 500 260 .065 x .133 9
24 TT-J-24 Solid PFA PFA 500 260 .056 x .092 6
24 TT-J-24S 7 x 32 PFA PFA 500 260 .063 x .102 6
30 TT-J-30†† Solid PFA PFA 500 260 .024 x .040 2
36 TT-J-36†† Solid PFA PFA 500 260 .019 x .030 2
40 TT-J-40†† Solid PFA PFA 500 260 .017 x .026 2
PFA Polymer
w/Twisted
& Shielded Conductors
20 TT-J-20-TWSH Solid PFA Polymer PFA Polymer and Shielding 500 260 .15 20
20S TT-J-20S-TWSH 7 x 28 PFA Polymer PFA Polymer and Shielding 500 260 .15 20
24 TT-J-24-TWSH Solid PFA Polymer PFA Polymer and Shielding 500 260 .11 9
24S TT-J-24S-TWSH 7 x 32 PFA Polymer PFA Polymer and Shielding 500 260 .12 9
Neoflon
FEP
20 FF-J-20 Solid FEP FEP 392 200 .068 x .116 11
24 FF-J-24 Solid FEP FEP 392 200 .056 x .092 7
FEP Polymer
w/Twisted & Shielded Conductors
20 FF-J-20-TWSH Solid FEP Polymer FEP Polymer and Shielding 392 200 .15 20
20S FF-J-20S-TWSH 7 x 28 FEP Polymer FEP Polymer and Shielding 392 200 .15 20
24 FF-J-24-TWSH Solid FEP Polymer FEP Polymer and Shielding 392 200 .11 9
24S FF-J-24S-TWSH 7 x 32 FEP Polymer FEP Polymer and Shielding 392 200 .12 9
TFE Tape Polymer 20 TFE-J-20 Solid TFE Tape Polymer Fused TFE Tape Polymer 500 260 .060 x .100 11
20S TFE-J-20S 7 x 28 TFE Tape Polymer Fused TFE Tape Polymer 500 260 .060 x .105 11
24 TFE-J-24 Solid TFE Tape Polymer Fused TFE Tape Polymer 500 260 .050 x .075 6
24S TFE-J-24S 7 x 32 TFE Tape Polymer Fused TFE Tape Polymer 500 260 .050 x .085 6
Polyvinyl  24 PR-J-24 Solid Polyvinyl (Rip Cord)*** 221 105 .050 x .086 5
24 PP-J-24S 7 x 32 Polyvinyl Polyvinyl 221 105 .080 x .130 5

*Has color tracers on jacket and conductors, XC= Max Insul Density, XT=Reduced Insul Density, XL=Minimum Insul Density-Looser Woven
**Has color tracers on jacket and positive leg only
***Two insulated leads bonded together, but with no overwrap.
†Weight of spool and wire rounded up to the next highest lb. (does not include packing material).
††Overall color clear

(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
Fiberglass Insulation
GG-J-30-SLE-1000
GG-J-30-SLE-1000
TWD18,548
Availability: 1 week
 
1000 ft, Glass Insulated, 30 AWG, Type J, Special Limits of Error
GG-J-24-SLE-1000
GG-J-24-SLE-1000
TWD17,762
Availability: 3 weeks
 
1000 ft, Glass Insulated, 24 AWG, Type J, Special Limits of Error
GG-J-20-1000
GG-J-20-1000
TWD21,159
Availability: 3 weeks
 
1000 ft, Glass Insulated, 20 AWG, Type J
GG-J-24-50
GG-J-24-50
TWD1,541
Availability: 1 week
 
50 ft, Glass Insulated, 24 AWG, Type J
GG-J-30-500
GG-J-30-500
TWD7,891
Availability: 1 week
 
500 ft, Glass Insulated, 30 AWG, Type J
GG-J-30-SLE-1000
GG-J-30-SLE-1000
TWD18,548
Availability: 1 week
 
1000 ft, Glass Insulated, 30 AWG, Type J, Special Limits of Error
GG-J-30-1000
GG-J-30-1000
TWD15,938
Availability: 20 weeks
 
1000 ft, Glass Insulated, 30 AWG, Type J
  
GG-J-24-SLE-500
TWD8,726
Availability: 1 week
 
500 ft, Glass Insulated, 24 AWG, Type J, Special Limits of Error
GG-J-24-SLE-1000
GG-J-24-SLE-1000
TWD17,762
Availability: 3 weeks
 
1000 ft, Glass Insulated, 24 AWG, Type J, Special Limits of Error
  
GG-J-24-500
TWD7,629
Availability: 3 weeks
 
500 ft, Glass Insulated, 24 AWG, Type J
  
GG-J-24-1000
TWD15,151
Availability: 1 week
 
1000 ft, Glass Insulated, 24 AWG, Type J
GG-J-20-500
GG-J-20-500
TWD10,556
Availability: 3 weeks
 
500 ft, Glass Insulated, 20 AWG, Type J
GG-J-20-1000
GG-J-20-1000
TWD21,159
Availability: 3 weeks
 
1000 ft, Glass Insulated, 20 AWG, Type J
PFG over Fiberglass Insulation
  
TG-J-36-1000
TWD37,322
Availability: 1 week
 
1000 ft, PFA Glass, 36 AWG, Type J
PFA Insulation
TT-J-30-SLE-100
TT-J-30-SLE-100
TWD4,558
Availability: 1 week
 
100 ft, PFA Insulated, 30 AWG, Type J, Special Limits of Error
TT-J-30-200
TT-J-30-200
TWD7,110
Availability: 3 weeks
 
200 ft, PFA Insulated, 30 AWG, Type J
TT-J-30-SLE-500
TT-J-30-SLE-500
TWD13,134
Availability: 1 week
 
500 ft, PFA Insulated, 30 AWG, Type J, Special Limits of Error
TT-J-30-1000
TT-J-30-1000
TWD23,952
Availability: 1 week
 
1000 ft, PFA Insulated, 30 AWG, Type J
TT-J-30-SLE-1000
TT-J-30-SLE-1000
TWD26,012
Availability: 1 week
 
1000 ft, PFA Insulated, 30 AWG, Type J, Special Limits of Error
TT-J-24-SLE-100
TT-J-24-SLE-100
TWD3,991
Availability: 1 week
 
100 ft, PFA Insulated, 24 AWG, Type J
TT-J-24-200
TT-J-24-200
TWD6,233
Availability: 1 week
 
200 ft, PFA Insulated, 24 AWG, Type J
TT-J-24-1000
TT-J-24-1000
TWD20,860
Availability: 1 week
 
1000 ft, PFA Insulated, 24 AWG, Type J
TT-J-24-SLE-1000
TT-J-24-SLE-1000
TWD23,176
Availability: 1 week
 
1000 ft, PFA Insulated, 24 AWG, Type J, Special Limits of Error
TT-J-20-SLE-500
TT-J-20-SLE-500
TWD15,194
Availability: 1 week
 
500 ft, PFA Insulated, 20 AWG, Type J, Special Limits of Error
TT-J-20-SLE-1000
TT-J-20-SLE-1000
TWD30,388
Availability: 1 week
 
1000 ft, PFA Insulated, 20 AWG, Type J, Special Limits of Error
TT-J-30-1000
TT-J-30-1000
TWD23,952
Availability: 1 week
 
1000 ft, PFA Insulated, 30 AWG, Type J
TT-J-24-500
TT-J-24-500
TWD10,406
Availability: 1 week
 
500 ft, PFA Insulated, 24 AWG, Type J
TT-J-24-SLE-500
TT-J-24-SLE-500
TWD11,486
Availability: 1 week
 
500 ft, PFA Insulated, 24 AWG, Type J Special Limits of Error
TT-J-20-100
TT-J-20-100
TWD4,660
Availability: 1 week
 
100 ft, PFA Insulated, 20 AWG, Type J
TT-J-20-500
TT-J-20-500
TWD13,391
Availability: 1 week
 
500 ft, PFA Insulated, 20 AWG, Type J
TT-J-20-SLE-500
TT-J-20-SLE-500
TWD15,194
Availability: 1 week
 
500 ft, PFA Insulated, 20 AWG, Type J Special Limits of Error
TT-J-20-SLE-1000
TT-J-20-SLE-1000
TWD30,388
Availability: 1 week
 
1000 ft, PFA Insulated, 20 AWG, Type J Special Limits of Error
TT-J-24-100
TT-J-24-100
TWD3,633
Availability: 1 week
 
100 ft, PFA Insulated, 24 AWG, Type J
TT-J-24S-500
TT-J-24S-500
TWD13,648
Availability: 3 weeks
 
500 ft, PFA Insulated, Stranded 24 AWG, Type J
TT-J-24-1000
TT-J-24-1000
TWD20,860
Availability: 1 week
 
1000 ft, PFA Insulated, 24 AWG, Type J
TT-J-24-SLE-1000
TT-J-24-SLE-1000
TWD23,176
Availability: 1 week
 
1000 ft, PFA Insulated, 24 AWG, Type J Special Limits of Error
TT-J-30-SLE-500
TT-J-30-SLE-500
TWD13,134
Availability: 1 week
 
500 ft, PFA Insulated, 30 AWG, Type J Special Limits of Error
TT-J-30-SLE-1000
TT-J-30-SLE-1000
TWD26,012
Availability: 1 week
 
1000 ft, PFA Insulated, 30 AWG, Type J Special Limits of Error
TT-T-30-SLE-500
TT-T-30-SLE-500
TWD14,680
Availability: 1 week
 
500 ft, PFA Insulated, 30 AWG, Type T, Special Limits of Error
TT-T-30-SLE-1000
TT-T-30-SLE-1000
TWD29,355
Availability: 1 week
 
1000 ft, PFA Insulated, 30 AWG, Type T, Special Limits of Error
TT-T-30-SLE-100
TT-T-30-SLE-100
TWD5,072
Availability: 1 week
 
100 ft, PFA Insulated, 30 AWG, Type T, Special Limits of Error
TT-T-30-500
TT-T-30-500
TWD13,391
Availability: 1 week
 
1000 ft, PFA Insulated, 30 AWG, Type T
TT-T-24S-SLE-1000
TT-T-24S-SLE-1000
TWD27,296
Availability: 1 week
 
1000 ft, PFA Insulated, 30 AWG, Type T, Special Limits of Error
TT-T-24-SLE-500
TT-T-24-SLE-500
TWD11,743
Availability: 1 week
 
500 ft, PFA Insulated, 24 AWG, Type T, Special Limits of Error
TT-T-24-SLE-1000
TT-T-24-SLE-1000
TWD23,690
Availability: 1 week
 
1000 ft, PFA Insulated, 24 AWG, Type T, Special Limits of Error
TT-T-20-SLE-500
TT-T-20-SLE-500
TWD14,680
Availability: 3 weeks
 
500 ft, PFA Insulated, 20 AWG, Type T, Special Limits of Error
TT-T-20-SLE-1000
TT-T-20-SLE-1000
TWD29,099
Availability: 3 weeks
 
1000 ft, PFA Insulated, 20 AWG, Type T, Special Limits of Error
TT-T-20-500
TT-T-20-500
TWD12,824
Availability: 3 weeks
 
500 ft, PFA Insulated, 20 AWG, Type K
  
TT-T-20-1000
TWD25,750
Availability: 3 weeks
 
1000 ft, PFA Insulated, 20 AWG, Type T
Polyvinyl (Rip Cord) Insulation
PR-J-24-100
PR-J-24-100
TWD1,423
Availability: 3 weeks
 
100 ft, Polyvinyl (Rip Cord)***, 24 AWG, Type J
Specialty Wire
  
GG-JI-20-SB-300M
TWD37,105
Availability: 1 week
 
300 meter, Glass Insulate w/SS Overbraiding, 20 AWG, Type J, IEC Color Code
All prices on this site are shown in Taiwan Dollars.
Ordering Example: (1) TT-J-20-500 PFA Insulated, Type ''T'', (Iron-Constantan), Thermocouple Wire, TWD13,391

Option Descriptions:


(1) Insulation select from:
HH for High Temp Glass (20 & 24 AWG Only)
GG for Glass
KK for Kapton Fused Polymide Tape (20 24 & 30 AWG Only)
TG for PFA and Glass (30 36 & 40 AWG Only)
TT for Neoflon PFA (High Performance)
FF for Neoflon FEP (20 & 24 AWG Only)
PP for Polyvinyl (24 Gauge Stranded Only)
PR for Polyvinyl Rip Cord (24 AWG Only)
XC for Ceramic (14 20 24 AWG Only)
XT for Ceramic (20 & 24 AWG Only)
XL for Ceramic (20 & 24 AWG Only)
XS for Silica (14 20 24 AWG Only)
TFE for TFE Tape Polymer (20 & 24 AWG Only)

(2) Gage select from:
14 for 14 AWG
20 for 20 AWG
20S for 20 AWG (Stranded)
24 for 24 AWG
24S for 24 AWG (Stranded)
28 for 28 AWG
30 for 30 AWG
36 for 36 AWG
40 for 40 AWG

(3) Additional Option select from:
Nothing(leave field blank) for None
-SB for SS Braid
-TWSH for Twisted and Shielded Conductors (Only available for TT or FF insulation 20 & 24 AWG Only)

(4) Special Limits of Error select from:
Nothing(leave field blank) for Standard
-SLE for Special Limits of Error

(5) Spool Length select from:
25 for 25 Feet
50 for 50 Feet
100 for 100 Feet
200 for 200 Feet
500 for 500 Feet
1000 for 1000 Feet
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.