XTPB and XTPR Series

Manual Motor Protectors | XTPB and XTPR Series

Manual Motor Protectors

See All Models Below

CE
  • Visible Trip Indication
  • Class 10 Overload Protection
  • Manual Motor Protectors up to 25A
  • UL 508 Group Motor and Type E Compliant
Drives & Motors - View related products

Description

Manual Motor Protectors (MMPs) features a pushbutton or rotary ON/OFF manual disconnect, Class 10 adjustable bimetallic overload relay and fixed magnetic short circuit trip capability in one compact unit. The Frame B size (45 mm) for motors has FLA ratings up to 32A. The XTPB and XTPR MMPs are UL Listed under UL 508 as Manual Motor Protectors. They provide an economical solution for applications requiring simple manual starting and stopping of motors. When used as an MMP, they are typically installed in an enclosure. Many enclosures are offered as accessories for the MMPs. Separate short-circuit protective devices, such as circuit breakers or fuses, are wired ahead of the MMPs. The short-circuit protective device should be sized per the NEC code and should not exceed 400% of the maximum FLA dial setting of the MMP. A Group Motor Installation can be defined as more than one motor circuit protected by a single set of fuses or circuit breaker on a motor branch circuit. This eliminates the need for individual fuses or circuit breakers for each motor circuit. Substantial component cost savings, panel space savings and reduced wiring installation time can be achieved in Group Motor Installations. The MMPs are tested and listed for group installation. If remote operation is required, a magnetic contactor can be wired in series with the MMP. Manual Motor Protectors are selected based on the overload current range required for a given motor. This current range is determined from the motor Full Load Ampere rating and Motor Service Factor usually found on the motor nameplate. For motors with service factors less than 1.15, multiply the motor FLA by 0.90 to select appropriate MMP. Example: For motor having FLA of 6.4 A and service factor of 1.0 (6.4 A x 0.90 = 5.76 A), select Model Number: XTPB6P3BC1
(Specify Model Number)
Part Number/Desc.
Qty
Description
IEC MANUAL MOTOR PROTECTOR
PUSHBUTTON
XTPB001BC1
TWD6,030
Availability: 8 weeks
 
MMP PB frame B class 10, 0.63 to 1 A
XTPB1P6BC1
TWD6,030
Availability: 8 weeks
 
MMP PB frame B class 10, 1 to 1.6 A
XTPB2P5BC1
TWD6,030
Availability: 8 weeks
 
MMP PB frame B class 10, 1.6 to 2.5 A
XTPB004BC1
TWD6,030
Availability: 1 week
 
MMP PB frame B class 10, 2.5 to 4 A
XTPB6P3BC1
TWD6,030
Availability: 8 weeks
 
MMP PB frame B class 10, 4 to 6.3 A
XTPB010BC1
TWD6,030
Availability: 8 weeks
 
MMP PB frame B class 10, 6.3 to 10 A
XTPB016BC1
TWD6,550
Availability: 8 weeks
 
MMP PB frame B class 10, 10 to 16 A
ROTARY
XTPR001BC1
TWD6,170
Availability: 8 weeks
 
MMP rotary frame B class 10, 0.63 to 1 A
XTPR1P6BC1
TWD6,170
Availability: 8 weeks
 
MMP rotary frame B class 10, 1 to 1.6 A
XTPR2P5BC1
TWD6,170
Availability: 1 week
 
MMP rotary frame B class 10, 1.6 to 2.5 A
XTPR004BC1
TWD6,170
Availability: 8 weeks
 
MMP rotary frame B class 10, 2.5 to 4 A
XTPR6P3BC1
TWD6,170
Availability: 8 weeks
 
MMP rotary frame B class 10, 4 to 6.3 A
XTPR010BC1
TWD6,170
Availability: 8 weeks
 
MMP rotary frame B class 10, 6.3 to 10 A
XTPR016BC1
TWD6,170
Availability: 8 weeks
 
MMP rotary frame B class 10, 6.3 to 10 A
XTPR020BC1
TWD7,395
Availability: 8 weeks
 
MMP rotary frame B class 10, 16 to 20 A
XTPR025BC1
TWD7,395
Availability: 9 weeks
 
MMP rotary frame B class 10, 20 to 25 A
MANUAL MOTOR PROTECTOR ACCESSORIES
XTPAXCLKA2
TWD945
Availability: 8 weeks
 
3-Ph commoning link A, 2 devices frame B
XTPAXCLKA3
TWD1,225
Availability: 8 weeks
 
3-Ph commoning link A, 3 devices frame B
XTPAXIT
TWD975
Availability: 8 weeks
 
Incoming terminals
XTPAXSA11
TWD975
Availability: 1 week
 
Side auxiliary contacts 1NO 1NC
XTPAXSA12
TWD1,515
Availability: 8 weeks
 
Side auxiliary contact 1NO 2NC
XTPBXENAS41
TWD2,100
Availability: 8 weeks
 
MMP PB accessory enclosure-N.A. surface IP41
XTPBXENAS65
TWD3,005
Availability: 8 weeks
 
MMP PB accessory enclosure-N.A. surface IP65
All prices on this site are shown in Taiwan Dollars.
Ordering Example: (1) XTPAXSA11 side auxiliary contacts, TWD975  plus (1) XTPB6P3BC1 manual motor protector 4 to 6.3 A, TWD6,030, TWD975 + 6,030 = TWD7,005