Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Taiwan: 0809 090 375
International+65 6415 5353

Flat Surface In Line pH/ORP Electrodes

PHE-5460 and ORE-5460

Flat Surface In Line pH/ORP Electrodes | PHE-5460 and ORE-5460

Flat Surface In Line pH/ORP Electrodes

TWD8,494 PHE-5460

  • 16 Month Shelf Life
  • Designed For 3/4", 1", or 2" Pipe Tees
  • Acryl Gel Standard For High Temperature Applications
  • CPVC Construction
  • Maximum Temperature 88°C (190°F)
Industrial pH Instrumentation and Electrodes - View related products

Description

In-Line Electrodes
The PHE/ORE-5460 in-line pH and ORP electrodes feature a flat self-cleaning abrasion-free surface. When exposed to turbulent flow, the resulting scrubbing action keeps the electrodes clean. The electrodes can be used in applications with 0 to 88°C (32 to 190°F) temperatures, pressures up to 6.89 bar (100 psig) and a 0 to 14 pH measurement range (0 to 12 without sodium ion error). Having fresh material sweeping past the electrode’s surface improves response time as well as accuracy, especially for the measurement of oily waste fluids, lime slurries, flocculant and emulsions. The electrodes accept a cable assembly with a gland mounted in a 3/4", 1"or 2" NPT tee.

In-Line electrodes are ideal for relacing existing threaded electrodes. They are used in applications where flow can be shut off for electrode maintenance.

The high temperature Acrylamide gel is supplied as standard with the PHE-5460 electrodes. These are only available with CPVC construction.

Electrode Options
Ordering Suffix Description Available In Line Models
-HFFluoride ResistantAll pH including PHE-5460-GL
-GLGround LoopPHE-5460 only (3/4")
-LCLow ConductivityAll pH


Please download PDF file for full specifications and a complete list of available models.
(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
pH Electrodes
PHE-5460
PHE-5460
TWD8,494
Availability: 1 week
 
pH Electrode for 3/4" pipe
  
PHE-5460-GL
TWD18,695
Availability: 3 weeks
 
pH Electrode ground loop interupter
  
PHE-5460-GL-LC
TWD19,385
Availability: 9 weeks
 
Low conductivity pH electrode for 3/4" pipe with ground loop interupter
  
PHE-5460-GLHF
Consult Sales  
Availability: 
 
 
Flouride Resistant pH electrode with ground loop interupter
  
PHE-5460-HF
TWD11,324
Availability: 8 weeks
 
Flouride resistant pH electrode
PHE-5460-LC
PHE-5460-LC
TWD9,694
Availability: 8 weeks
 
Low conductivity pH electrode
PHE-5460-1
PHE-5460-1
TWD11,069
Availability: 8 weeks
 
pH electrode for 1" pipe
  
PHE-5460-1-GL-HF
TWD24,115
Availability: 9 weeks
 
Flouride resistant pH electrode with ground loop interupter
  
PHE-5460-1-HF
TWD11,890
Availability: 8 weeks
 
Flouride resistant pH electrode
  
PHE-5460-1-LC
TWD11,030
Availability: 9 weeks
 
Low conductivity pH electrode
  
PHE-5460-2
TWD11,704
Availability: 1 week
 
pH electrode for 2" pipe
  
PHE-5460-2-GL-HF
TWD25,640
Availability: 9 weeks
 
Flouride resistant pH electrode with ground loop interupter
ORP Electrodes
ORE-5460
ORE-5460
TWD10,160
Availability: 1 week
 
ORP electrode for 3/4" pipe
  
ORE-5460-1
TWD11,995
Availability: 9 weeks
 
ORP electrode for 1" pipe
  
ORE-5460-1-LC
TWD13,965
Availability: 9 weeks
 
Low conductivity ORP electrode for 1" pipe
  
ORE-5460-2
TWD14,470
Availability: 8 weeks
 
ORP electrode for 2" pipe
Mounting Assemblies (CPVC) Are Required for Installation. For additional configurations see the Part Number Builder below this table.
Compatible with PHE/ORE-5460 Series
PHEH-54-10
PHEH-54-10
TWD4,831
Availability: 1 week
 
3/4 NPT mounting assembly and cable without ATC
PHEH-54-10-PT100
PHEH-54-10-PT100
TWD12,191
Availability: 8 weeks
 
3/4 NPT mounting assembly and cable with 100 Ohm ATC
PHEH-54-10-PT1K
PHEH-54-10-PT1K
TWD12,190
Availability: 8 weeks
 
3/4 NPT mounting assembly and cable with 1000 Ohm ATC
  
PHEH-54-10-R3K
TWD12,190
Availability: 9 weeks
 
3/4 NPT mounting assembly and cable with 3000 Ohm Balco ATC
  
PHEH-54-10-300
Consult Sales  
Availability: 
 
 
3/4 NPT mounting assembly and cable with 300 Ohm Thermistor ATC
  
PHEH-54-15
TWD5,355
Availability: 9 weeks
 
3/4 NPT mounting assembly and 15 feet of cable without ATC
  
PHEH-54-15-PT100
TWD14,460
Availability: 9 weeks
 
3/4 NPT mounting assembly and 15 feet of cable with 100 Ohm ATC
  
PHEH-54-20
TWD5,840
Availability: 8 weeks
 
3/4 NPT mounting assembly and 20 feet of cable without ATC
  
PHEH-54-20-PT100
TWD13,625
Availability: 8 weeks
 
3/4 NPT mounting assembly and 20 feet of cable with 100 Ohm ATC
  
PHEH-54-20-PT1K
TWD13,625
Availability: 9 weeks
 
3/4 NPT mounting assembly and 20 feet of cable with 1000 Ohm ATC
  
PHEH-54-25-PT1K
TWD14,820
Availability: 9 weeks
 
3/4 NPT mounting assembly and 25 feet of cable with 1000 Ohm ATC
  
PHEH-54-30
TWD6,120
Availability: 9 weeks
 
3/4 NPT mounting assembly and 30 feet of cable without ATC
  
PHEH-54-30-PT100
TWD15,537
Availability: 9 weeks
 
3/4 NPT mounting assembly and 30 feet of cable with 100 Ohm ATC
  
PHEH-54-33-PT100
TWD17,615
Availability: 9 weeks
 
3/4 NPT mounting assembly and 33 feet of cable with 100 Ohm ATC
  
PHEH-54-35-PT100
TWD16,255
Availability: 9 weeks
 
3/4 NPT mounting assembly and 35 feet of cable with 100 Ohm ATC
  
PHEH-54-40-PT1K
TWD16,730
Availability: 9 weeks
 
3/4 NPT mounting assembly and 40 feet of cable with 1000 Ohm ATC
  
PHEH-54-50
TWD7,985
Availability: 9 weeks
 
3/4 NPT mounting assembly and 50 feet of cable without ATC
  
PHEH-54-50-PT100
TWD18,165
Availability: 9 weeks
 
3/4 NPT mounting assembly and 50 feet of cable with 100 Ohm ATC
  
PHEH-54-60-PT100
TWD19,360
Availability: 9 weeks
 
3/4 NPT mounting assembly and 60 feet of cable with 100 Ohm ATC
  
PHEH-54-100-PT100
TWD24,620
Availability: 9 weeks
 
3/4 NPT mounting assembly and 100 feet of cable with 100 Ohm ATC
Compatible with PHE/ORE-5460-1 Series
  
PHEH-54-10-1
TWD5,500
Availability: 8 weeks
 
1NPT mounting assembly and cable without ATC
  
PHEH-54-10-1-PT100
TWD13,145
Availability: 8 weeks
 
1 NPT mounting assembly and cable with 100 Ohm ATC
  
PHEH-54-10-1-PT1K
TWD13,145
Availability: 9 weeks
 
1 NPT mounting assembly and cable with 1000 Ohn ATC
  
PHEH-54-10-1-R3K
TWD14,460
Availability: 9 weeks
 
1 NPT mounting assembly and cable with 3000 Ohm Balco ATC
Compatible with PHE/ORE-5460-2 Series
  
PHEH-54-10-2
Consult Sales  
Availability: 
 
 
2 NPT mounting assembly and cable without ATC
  
PHEH-54-10-2-PT100
TWD15,515
Availability: 1 week
 
2 NPT mounting assembly and cable with 100 Ohm ATC
  
PHEH-54-10-2-PT1K
TWD14,105
Availability: 9 weeks
 
2 NPT mounting assembly and cable with 1000 Ohm ATC
  
PHEH-54-10-2-R3K
TWD14,105
Availability: 9 weeks
 
2 NPT mounting assembly and cable with 3000 Ohm Balco ATC
  
PHEH-54-10-2-300
Consult Sales  
Availability: 
 
 
2 NPT mounting assembly and cable with 300 Ohm ATC
  
PHEH-54-15-2-PT100
TWD15,300
Availability: 9 weeks
 
2 NPT mounting assembly with 15 feet of cable and 100 Ohm ATC
Accessories
PHA-10
PHA-10
TWD660
Availability: 1 week
 
PH 10 buffer solution 500 mL (1 pt)
PHA-10-GAL
PHA-10-GAL
TWD1,645
Availability: 1 week
 
PH 10 buffer solution 4L (1 gal)
PHA-4
PHA-4
TWD625
Availability: 1 week
 
PH 4 buffer solution 500 ml (1 pt)
PHA-4-GAL
PHA-4-GAL
TWD1,557
Availability: 1 week
 
PH 4 buffer solution 4L (1 gal)
PHA-7
PHA-7
TWD625
Availability: 1 week
 
PH 7 buffer solution 500 ml (1 pt)
PHA-7-GAL
PHA-7-GAL
TWD1,557
Availability: 2 weeks
 
PH 7 buffer solution 4L (1 gal)
PHA-DI
PHA-DI
TWD734
Availability: 1 week
 
De-ionized water 500 ml (1 pt)
PHA-DI-GAL
PHA-DI-GAL
TWD1,841
Availability: 1 week
 
De-ionized water 4L (1 gal)
  
PHAB-DI
TWD1,670
Availability: 3 weeks
 
20 single use foil packets of de-ionized water
PHAB-PH
PHAB-PH
TWD1,669
Availability: 1 week
 
5 each single use foil packets of PH-4, PH-7, PH-10, and de-ionized water
All prices on this site are shown in Taiwan Dollars.
Note: Comes complete with Electrode Care Instruction Sheet.

Temperature compensation is not required with ORP electrodes.

Electrodes must be mounted vertically and kept moist.

Order electrode and mounting assemblies separately. Materials of construction must be the same.

* Since April 2010 the cap on the mounting assembly was extended 1/4 of an inch, 1/2 NPT threads added for use when attaching cap to threaded conduit, and grip dimples were added for ease of use.

For 5% HF application, add suffix "-HF" to electrode model number, add $50 to price.

For low conductivity application, add suffix "-LC" to electrode model number, add $30 to price.

For ground loop interrupt Circuit, add suffix "-GL" to electrode model number, add $158 to price.

Mounting assemblies supplied with 3 m (10') of cable with BNC connector.

For non-standard cable lengths up to 15 m (50') replace the suffix "-10" in the model number with the desired length in feet, add $2 per foot to price. (Additional cost of $2 per foot applies to entire cable length).


Ordering Example: (1) PHE-5460 Electrode, TWD8,494  plus (1) PHEH-54-10 Mounting Assembly, TWD4,831, TWD8,494 + 4,831 = TWD13,325

Option Descriptions:


(1) NPT select from:
Nothing(leave field blank) for 3/4 in. NPT
-1 for 1 in. NPT
-2 for 2 in. NPT

(2) ATC Sensor select from:
Nothing(leave field blank)
-PT100 for 100 ohm platinum RTD
-PT1K for 1000 ohm platinum RTD
-R3K for 3000 ohm Balco
-300 for 300 ohm Thermistor
-TH700 for 700 Series Thermistor
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.