More»
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation

RTD Input DIN Rail Signal Conditioners

DRSL-RTD_Series   
1 year warranty CE
 
RTD Input DIN Rail Signal Conditioners
DRSL-RTD_Series:RTD Input DIN Rail Signal Conditioners
Click for larger image.
   
$316.00  DRSL-RTD-ISO
DRSL-RTD Non-Isolated and DRSL-RTD-ISO Isolated Models
2, 3 or 4-Wire Pt100 RTD Input
Pre-Calibrated Temperature Ranges Selectable via Dip-Switches
Slimline Housing—Only 6 mm (0.24") Wide
High Accuracy
Fast Response Time <30 ms/300 ms (Selectable)
Excellent EMC Performance and 50/60 Hz Noise Suppression

View related products - Process Measurement and Control Instruments

Click to scroll below to order See Specs PDF Manuals Related Items View a printer friendly page

The DRSL-RTD Series RTD input DIN rail signal conditioners provide a competitive choice in terms of both price and technology for interfacing RTD inputs to SCADA systems or PLC equipment. The DRSL-RTD and DRSL-RTD-ISO can be used for signal conversion of 2, 3 or 4-wire Pt100 RTD inputs into unipolar analog signals. The DRSL-RTD-ISO isolated model offers 3-way isolation between input, output and supply and provides surge suppression and protects control systems from transients and noise. Low power consumption facilitates DIN rail mounting without the need for any air gap. Easy configuration of more than 1000 factory calibrated measurement ranges is done via DIP-switches. The unit operates over a wide temperature range from -25 to 70°C (-13 to 158°F).

SPECIFICATIONS
INPUT
Input Type: 2, 3, or 4-wire Pt100 RTD
Temperature Range: -200 to 850°C (-328 to 1562°F)
Sensor Current, RTD: <150 µA
Sensor Cable Specifications: 50 Ω per wire or 50 nF
Effect of Sensor Cable Resistance (3 or 4-wire RTD): <0.002 Ω/Ω
Broken Sensor Detection: >800 Ω
Shorted Sensor Detection: <18 Ω

OUTPUT
Current Output
Programmable Signal Ranges: 0 to 20 mA and 4 to 20 mA
Range Limits (NAMUR NE43 Out of Range): Below 3.8 mA or above 20.5 mA for 4 to 20 mA output; 0 mA or above 20.5 mA for 0 to 20 mA output
Sensor Error Detection (Dip Switch Selectable for Enable or None): Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output
Incorrect DIP-Switch Setting Identification: Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output
Output Error Level: DIP switch selectable for upscale or downscale
Load: 21 mA/600Ω /12.6V max
Load Stability: ≤0.01% of span/100Ω
Voltage Output
Programmable Signal Ranges: 0 to 10 V, 2 to 10 V, 0 to 5 V and 1 to 5 V
Range Limits (Out of Range): Range ±2.5%
Sensor Error Detection (Dip Switch Selectable for Enable or None): 0V or selected range + 10%
Incorrect DIP-Switch Setting Identification: 0V
Output Error Level: DIP switch selectable for upscale or downscale
Load: >10 kΩ min

GENERAL
Supply Voltage
    DRSL-RTD: 16.8 to 31.2 Vdc via connectors
    DRSL-RTD-ISO: 16.8 to 31.2 Vdc via power rail or connectors
Power Consumption: 0.7 W max
Internal Consumption: 0.65 W max
Isolation (DRSL-RTD-ISO Only): Input/output/supply
Isolation Voltage, Test (DRSL-RTD-ISO Only): 2.5 kVac (reinforced)
Isolation Voltage, Working (DRSL-RTD-ISO Only): 300 Vac
Status LED: Green LED indicates operational status of the unit and input sensor
    Normal Operation: Flashes for 15 ms at 13 Hz rate
    Sensor Error: Flashes for 15 ms at 1 Hz rate
    Incorrect DIP Switch Setting: flashes for 500 ms at 1 Hz rate
    Hardware Failure: LED off
Signal/Noise Ratio: >60 dB
Response Time (0 to 90%, 100 to 10%): <30 ms/300 ms (selectable, provides either fast response or signal dampening as needed)
Accuracy
    DRSL-RTD: Better than 0.2°C or ±0.1% of selected input range
    DRSL-RTD-ISO: Better than 0.1°C or ±0.05% of selected input range
Temperature Coefficient: ≤±0.02°C/°C
EMC Immunity Influence: <±0.5% of span
Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span (span = selected input range)

ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II

MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm²/ AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm


To Order (Specify Model Number)    
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 
Most Popular Models Highlighted!
 Part Number   Availability   Price   Description    Qty.
Click to expand/minimize a list of what others bought with the DRSL-RTD  DRSL-RTD 2 weeks   232.00    Non-isolated RTD input DIN rail signal conditioner  
    DRSL-RTD-ISO 2 weeks   316.00    Isolated RTD input DIN rail signal conditioner  
 Accessories
Click to expand/minimize a list of what others bought with the DRSL-PWR-RAIL  DRSL-PWR-RAIL 2 weeks   284.00    Power rail (with cover and two end covers, one right hand and one left hand), 1 m (3.3') length for use with DRSL-RTD-ISO only  
Click to expand/minimize a list of what others bought with the DRSL-PCU  DRSL-PCU 2 weeks   195.00    Power connector unit, 24 Vdc/2.5 A output to power rail for use with DRSL-RTD-ISO only  
    DRSL-MOD-STOP 2 weeks   13.00    Module stop (screwed onto power rail to support and hold mounted devices)  
All dollar amounts on this site are shown in Singapore currency.

 Ordering Example: (1) DRSL-MOD-STOP Module stop (screwed onto power rail to support and hold mounted devices), $13.00,  plus (1) DRSL-PCU Power connector unit, 24 Vdc/2.5 A output to power rail, $195.00,  plus (1) DRSL-PWR-RAIL Power rail (with cover and two end covers, one right hand and one left hand), 1 m (3.3') length, $284.00,  plus (1) DRSL-RTD-ISO Isolated RTD input DIN rail signal conditioner, $316.00, $13.00 + 195.00 + 284.00 + 316.00 = $808

 Related Links - Manual, Related Products
 Product Manual
   Download Installation Guide for Signal Conditioners
   Download DIN Rail Isolators and Signal Conditioners
 Related Products
DRSL-DC1 DRSL-DC1:
Isolated DIN Rail Repeater
DRSL-DC2 DRSL-DC2:
Isolated DIN Rail Signal Conditioner
DRSL-DC3 DRSL-DC3:
Isolated DIN Rail Signal Conditioner
DRSL-DC4 DRSL-DC4:
Bipolar Isolated DIN Rail Signal Conditioner for Process Signals
DRSL-LPI_Series DRSL-LPI_Series:
DIN Rail Input Loop-Powered Isolators
DRSL-LPO_Series DRSL-LPO_Series:
DIN Rail 2-Wire Transmitter Isolators
DRSL-RTD-LP DRSL-RTD-LP:
RTD Input Non-Isolated DIN Rail Loop-Powered Signal Conditioner
DRSL-SP1 DRSL-SP1:
Isolated DIN Rail Repeater/Splitter for Current Signals
DRSL-SP2 DRSL-SP2:
Isolated DIN Rail Signal Conditioner/Splitter for Process Signals
DRSL-SP3 DRSL-SP3:
Bipolar Isolated DIN Rail Signal Conditioner/Splitter for Process Signals
DRSL-TC_Series DRSL-TC_Series:
Thermocouple Input DIN Rail Signal Conditioners
DRSL-TEMP DRSL-TEMP:
Isolated DIN Rail Loop-Powered Temperature Signal Conditioner
DRSL-U DRSL-U:
Isolated Universal Input DIN Rail Signal Conditioner
   
Keywords:RTD Input DIN Rail Signal Conditioners

   Back to topBack to top