Finned Tubular Air Heating Elements  - Discontinued

FTS Series   
RoHS
 
Finned Tubular Air Heating Elements
FTS Series:Finned Tubular Air Heating Elements  - Discontinued
Click for larger image.
   
Maximum Sheath Temp. 455°C (850°F)
Fins for Fast Heat Transfer
725 to 5000 Watts
120 and 240 Vac Applications
APPLICATIONS
• Drying
• Heat Treating
• Annealing
• Load Banks
• Curing


View related products - Process Air and Duct Heaters

Click to scroll below to order See Specs PDF

The FTS series has been discontinued. Please contact our Temperature Engineering department for a viable replacement.

Finned tubular air heating elements are constructed like basic tubular elements with the addition of continuous spiral fins, 4-5 per inch permanently furnace brazed to the sheath.Fins greatly increase surface area and permit faster hear transfer to air, resulting in lower surface element temperatures.

Refer to the following table for element dimensions

Model No. Watts Volts Dimensions cm (in)
A B F H
0.80 cm (0.315") Sheath Diameter (D) Approximately 60 W/sq. in.
FTS-015315/120V50012038 (15)26.7 (101/2)2.14 (.844)20.2 (81/4)
FTS-024315/120V102512061 (24)49.5 (191/2)2.14 (.844)42.3 (171/4)
FTS-036315/120V175012091 (36)80 (311/2)2.14 (.844)71.1 (291/4)
FTS-048315/240V2450240122 (48)110 (431/2)2.14 (.844)101.1 (411/4)
FTS-063315/240V3500240160 (63)149 (581/2)2.14 (.844)137.8 (561/4)
1.2 cm (0.475) Sheath Diameter (D) Approximately 9.3 W/cm2 (60 W/in2)
FTS-015475/120V72512038 (15)26.7 (101/2)2.90 (1.14)22 (8 5/8)
FTS-024475/120V145012061 (24)49.5 (191/2)2.90 (1.14)45 (17 5/8)
FTS-036475/240V245024091 (36)80 (311/2)2.90 (1.14)75 (29 5/8)
FTS-048475/240V3450240122 (48)110 (431/2)2.90 (1.14)106 (41 5/8)
FTS-063475/240V5000240160 (63)149 (581/2)2.90 (1.14)144 (56 5/8)


1.2 cm (0.475") Diameter Sheath and Bending Information

Finned Tubular Bending - Dimensions cm (inches)
Element
Dia. cm (in)
Factory
Min C
Bending
Min R
Customer
Min. C
Bending
Min. R
Figure 1*
.800 (.315)5.87 (2 5/16)2.78 (1 3/32)5.87 (2 5/16)2.94 (1 5/32)
1.20 (.475)8.57 (3 3/8)4.29 (1 11/16)8.57 (3 3/8)4.29 (1 11/16)
Figure 2**
.800 (.315)17.6 (6 15/16)2.62 (1 1/32)24.8 (9 3/4)2.62 (1 1/32)
1.20 (.475)25.7 (10 1/8)4.29 (1 11/16)34.4 (13 9/16)4.29 (1 11/16)
* The overall length of A will be slightly less than one-half the original sheath length, depending on bending radius. ** The overall length of A will be approximately 3.8 cm (11/2") longer than one-fourth of the original sheath length depending on the bending radius R. Note: the start of any bends should be no closer than 8.7 cm (37/16") for 1.2 cm (0.475") dia. or 9.2 cm (35/8") for 0.8 cm (0.315") elements, from the end of the sheath to prevent the heating element/cold pin junction from being located in the bend.




To Order (Specify Model Number)    
 Part Number   Availability   Price   Description RoHS   Qty.
 0.80 cm (0.315") Sheath Diameter (D) Approximately 60 W/sq. in.
 FTS-015246/120V    Consult sales   finned air heater RoHS compliant
 FTS-024315/120V    Consult sales   finned air heater RoHS compliant
 FTS-015315/120V    Consult sales   finned air heater RoHS compliant
 FTS-036315/120V    Consult sales   finned air heater RoHS compliant
 FTS-048315/240V    Consult sales   finned air heater RoHS compliant
 1.2 cm (0.475) Sheath Diameter (D) Approximately 9.3 W/cm2 (60 W/in2)
 FTS-015475/120V    Consult sales   finned air heater RoHS compliant
 FTS-024475/120V    Consult sales   finned air heater RoHS compliant
 FTS-036475/240V    Consult sales   finned air heater RoHS compliant
 FTS-048475/240V    Consult sales   finned air heater RoHS compliant
 FTS-063475/240V    Consult sales   finned air heater RoHS compliant
All dollar amounts on this site are shown in Singapore currency.

 Note: Other heaters with monel sheath [max. temp. 565°C (1050°F)] are available. Contact OMEGALUX™ at 1-800-826-6342.

   
Keywords:Finned Tubular Air Heating Elements, measuring vibration portable data loggers vibration measurements water level loggers