X-Series - Multi Channel Current Data Loggers
|
Click for larger image. |
|
|
$1,790.00
OM-CP-OCTPROCESS-160MA-A2
|
|
16-bit Readings Provide High Resolution
|
|
User-defined Engineering Units
|
|
Pushbutton or Programmable Start Time
|
|
External Power or User Replaceable Battery
|
|
Real Time Operation
|
|
Up to 4 Hz Reading Rate
|
|
NIST Traceable Calibration Certificate Included
|
|
Configurable Channel Names
|
View related products - Data Loggers
|
| |
|
|
|
The new OM-CP-ProcessX Series consists of 4, 8, 12 and 16-channel, battery powered, low level DC current data loggers with a reading rate of up to 4 Hz. X-Series devices ship with a standard USB-A to Micro USB cable for use with free OM-CP PC based software. The X-series has a high memory capacity and increased download speed compared to previous generations of product.
These easy-to-use devices feature an 18 month typical battery life, user replaceable battery and programmable engineering units. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. To maximize memory capacity, users can enable or disable channels. For easy identification, each channel can be named with up to a ten digit title.
Using the OM-CP Data Logger Software, starting, stopping and downloading from the OM-CP-ProcessX Series data loggers is simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.
Specifications
MEASUREMENT
|
Input Connection
|
3-input removable screw terminals
|
Model
|
30 mA |
160 mA |
3 A |
Current Range
|
-2 mA to +30 mA |
±160 mA |
±3 A |
Current Resolution
|
0.0005 mA |
0.005 mA |
0.001 A |
Calibrated Accuracy
|
±0.016 mA |
±0.16 mA |
±0.009 A |
Input Impedance
|
10 Ω |
1 Ω |
0.1 Ω |
Overload Protection (-0.3 V to +3.5 V)
|
±316 mA |
±1000 mA |
±6 A |
Maximum Voltage Between Inputs to Ground
|
3 V (Common mode voltage must be less than 3 volts. All inputs must be within 3 volts of all other inputs.)
|
Analog Conversion Time
|
150 ms
|
Temperature Coefficient
|
< 50ppm/°C typical
|
Engineering Units
|
Native Measurement units can be scaled to display measurement units of another type. This is useful when monitoring current outputs from different types of sensors such as temperature, CO2, flow rate and more.
|
GENERAL
|
Memory (All channels enabled)
|
4-channel: 1,048,064 readings per channel 8-channel: 524,032 readings per channel 12-channel: 349,354 readings per channel 16-channel: 262,016 readings per channel
|
Start Modes
|
Software programmable immediate start or delay start, up to 6 months in advance
|
Real Time Recording
|
May be used with PC to monitor and record data in real time
|
LEDs
|
1 per channel and 2 status LEDs
|
Reading Rate
|
4 Hz up to 1 reading every 24 hours
|
Calibration
|
Digital calibration through software
|
Calibration Date
|
Automatically recorded within device
|
Battery Type
|
9 V lithium included, user replaceable
|
Battery Life
|
18 months typical
|
Data Format
|
Date and time stamped A, mA, µA engineering units specified through software
|
Time Accuracy
|
±1 minute/month
|
Computer Interface
|
USB-A to micro USB cable (included); 460,800 baud
|
Operating System Compatibility
|
Windows XP SP3/7/8/10
|
Software Compatibility
|
Standard Software version 4.2.19.0 or later Secure Software version 4.2.18.0 or later
|
Operating Environment
|
-20 °C to +60 °C(-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing
|
Dimensions
|
4-channel: 2.70 in × 7.25 in × 1.22 in (65.6 mm × 184.2 mm × 31.0 mm) 8-channel: 2.70 in × 7.25 in × 1.22 in (65.6 mm × 184.2 mm × 31.0 mm) 12-channel: 2.70 in × 7.25 in × 1.68 in (65.6 mm × 184.2 mm × 42.7 mm) 16-channel: 2.70 in × 7.25 in × 2.14 in (65.6 mm × 184.2 mm × 54.4 mm)
|
Weight
|
4-channel: 13 oz (368 g) 8-channel: 13 oz (368 g) 12-channel:20 oz (580 g) 16-channel: 28 oz (800 g)
|
Enclosure
|
Black anodized aluminum
|
Approvals
|
CE, ROHS
|
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in Singapore currency.
|
|
|
|
|
| |
|
|
Keywords:process datalogger,datalogger,process datalogger,om-cp-process
|