X-Series - Multi Channel RTD Temperature Loggers
|
Click for larger image. |
|
|
$2,110.00
OM-CP-OCTRTDTEMP-A2
|
|
±0.04 °C Calibrated Accuracy
|
|
Real time Operation
|
|
Up to 4 Hz Reading Rate
|
|
Pushbutton or Programmable Start Time
|
|
Configurable Channel Names
|
|
NIST Traceable Calibration Certificate Included
|
|
External Power or User Replaceable Battery
|
|
Accepts 2, 3 and 4-wire RTD’s
|
View related products - Data Loggers
|
| |
|
|
|
The new OM-CP-RTDTempX Series consists of 4, 8, 12 and 16-channel RTD Temperature data logger with a reading rate of up to 4 Hz. X-Series devices ship with a standard USB-A to Micro USB cable for use with free OM-CP PC based software. The X-series has a high memory capacity and increased download speed compared to previous generations of product.
To maximize memory capacity, users can enable or disable channels. For easy identification, each channel can be named with up to a ten digit title.
Using the OM-CP Data Logger Software, starting, stopping and downloading from the OM-CP-RTDTempX Series data loggers is simple and easy. Graphical, tabular and statistical data is provided for analysis and data can be viewed in multiple units, using the Engineering Units function. The data can also be automatically exported to Excel® for further calculations.
* Temperature specifications based on ideal 100 Ω Pt RTD compliant with IEC 751 (1983) and ITS-90, 5000 Ω FSR (accuracy based on 36 inch lead wire RTD with 4 wire configuration)
** Calibrated accuracies based on standard Omega calibrations for 0 Ω to200 Ω range.
Specifications
TEMPERATURE
|
Temperature Range*
|
18.5 Ω to 390.5 Ω -200 °C to +850 °C (-328 °F to +1562 °F) (Probe Dependent)
|
Temperature Resolution
|
0.0001 Ω 0.001 °C (0.0018 °F) (Probe Dependent)
|
Calibrated Accuracy**
|
±0.015 Ω @ 25 °C (77 °F) ambient ±0.04 °C (±0.072 °F) (Probe Dependent)
|
Specified Accuracy Range
|
18.5 Ω to 175.9 Ω -200 °C to +200 °C(-328 °F to 392 °F)
|
Input Connection
|
Removable screw terminal; 2, 3 0r 4 wire interface
|
Temperature Coefficient
|
2 ppm/°C typical
|
GENERAL
|
Memory (All channels enabled)
|
4-channel: 698,709 readings per channel 8-channel: 349,354 readings per channel 12-channel: 232,903 readings per channel 16-channel: 174,677 readings per channel
|
Start Modes
|
Software programmable immediate start or delay start, up to 6 months in advance
|
Real Time Recording
|
May be used with PC to monitor and record data in real time
|
LEDs
|
1 per channel and 2 status LEDs
|
Reading Rate
|
4 Hz up to 1 reading every 24 hours
|
Calibration
|
Digital calibration through software
|
Calibration Date
|
Automatically recorded within device
|
Battery Type
|
9 V lithium included, user replaceable
|
Battery Life
|
18 months typical
|
Data Format
|
Date and time stamped C,°F,K,°R;Ω µV engineering units specified through software
|
Time Accuracy
|
±1 minute/month
|
Computer Interface
|
USB-A to micro USB cable (included); 460,800 baud
|
Operating System Compatibility
|
Windows XP SP3/7/8/10
|
Software Compatibility
|
Standard Software version 4.2.19.0 or later Secure Software version 4.2.18.0 or later
|
Operating Environment
|
-20 °C to +60 °C(-4 °F to +140 °F), 0 %RH to 95 %RH non-condensing
|
Dimensions
|
4-channel: 2.70 in × 7.25 in × 1.22 in (65.6 mm × 184.2 mm × 31.0 mm) 8-channel: 2.70 in × 7.25 in × 1.22 in (65.6 mm × 184.2 mm × 31.0 mm) 12-channel: 2.70 in × 7.25 in × 1.68 in (65.6 mm × 184.2 mm × 42.7 mm) 16-channel: 2.70 in × 7.25 in × 2.14 in (65.6 mm × 184.2 mm × 54.4 mm)
|
Weight
|
4-channel: 13 oz (368 g) 8-channel: 13 oz (368 g) 12-channel:20 oz (580 g) 16-channel: 28 oz (800 g)
|
Enclosure
|
Black anodized aluminum
|
Approvals
|
CE, ROHS
|
|
| |
|
|
|
|
|
† All dollar amounts on this site are shown in Singapore currency.
|
|
|
|
|
| |
|
|
Keywords:rtd datalogger,tc datalogger,quadrtdtemp,octrtdtemp,om-cp-quadrtdtemp,om-cp-octrtdtemp,quadrtdtemp,octrtdtemp,x series,xrtdtemp series
|