More»
 Accessibility  Skip navigation  Site Map  Help  Search field  View shopping cart  View shopping cart  Skip to Navigation

SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment

SA1-RTD Series   
 
SA1-RTD Series:SA1-RTD Surface-Mount RTD Temperature sensor | Quick Shipment
Click for larger image.
   
$162.00  SA1-RTD
Surface Mount RTD 100 Ω DIN Class A (±0.06 Ω or ±0.15°C at 0°C) Accuracy Standard
Easy-Installation Silicone-Based, Self-Adhesive Backing Rated to 260°C (500°F)
Back Can be Reapplied
Temperature Range; -73C to 260°C Continuous, 290°C (554°F) Short Term Operation When Installed with OMEGABOND Air Set Cements
Stripped 3-Wire Leads Standard (Connectors Optional), Color Code: Black/Black/Red
Optional 4-Wire Configuration (Color Code: Black/Black/Red/Red)
Stocked in 1 m (40") Lengths; Also Available in 2 and 3 m (80 and 120") and Custom Length Lead Wires
Other Resistances/Accuracies Available on Request
Stainless Steel Overbraid Option to reduce electrical noise and protect lead wire from abrasion

View related products - RTD (PT100) Probes, Elements and Assemblies

Click to scroll below to order See Specs PDF Manuals Related Items View a printer friendly page

SPECIFICATIONS
Minimum/Maximum Temperature: -73°C (-100°F) to 260°C (500°F) continuous, 290°C (554°F) short term (when cemented in place)
Sensing Element: 100 Ω at 0°C (32°F), temp coefficient of 0.00385 Ω/Ω/°C (IEC60751)
Accuracy: ±0.06% at 0°C (Pt100 DIN Class A)
Stability: Less than 0.2°C drift/year
Response Time: Less than 1sec. in water (63% response), less than 2sec. on a hot plate
Self-Heating Effect: 2.5 mW/°C
Lead Wire: 1 m (40"), 26 AWG, nickel-plated copper, PFA-insulated 3-wire, Color Code: Black/Black/Red

The SA1-RTD surface-mount RTD temperature sensor mounts on flat or curved surfaces and provides Class A accuracy (See IEC 751 Class A/B Standard Tolerances Table, below) for critical temperature monitoring applications. Based on a 2 x 2 x 0.8 mm Pt100 thin-film and supplied with bare 3-wire leads as a standard configuration (connector optional), it can be customized for use in a wide variety of applications. The surface mount temperature sensor can be easily applied with its self-adhesive backing, or positioned permanently with OMEGABOND™ cements.

Use the SA1-RTD to monitor chip, heat sink, and environmental temperatures in electronic devices; check piping or ducting temperatures; monitor motor and transformer core heat; test insulation capabilities; and check other applications in which surface and/or gradient temperatures need to be monitored or controlled


Also Available with Stainless Steel Overbraid
For applications where electrical noise is prevalent or where sensor lead wire is being routed around sharp edges, the stainless steel overbraid option (-SB) reduces noise and safeguards wire leads. Add "-SB" to the end of the part number listed in the table on the spec sheet, and add $3.50/ft.

IEC 751 Class A/B Standard Tolerances
Temp.
(°C)
Tolerance Class
Class A*Class B
±°C±Ω±°C±Ω
-2000.550.241.30.56
-1000.350.140.80.32
0.00.150.060.30.12
1000.350.130.80.30
2000.550.201.30.48
3000.750.271.80.64
4000.950.332.30.79
5001.150.382.80.93
6001.350.433.31.06
*SA1-RTDs are IEC 751 Class A Devices.



To Order (Specify Model Number)    
expand list What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.
 
Most Popular Models Highlighted!
 Part Number   Availability   Price   Description    Qty.
Click to expand/minimize a list of what others bought with the SA1-RTD  SA1-RTD 2 weeks   162.00    3-wire Pt100, 40 Inches (1m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)  
    SA1-RTD-SB 2 weeks   191.00    3-wire Pt100, 40 Inches with SS Over braiding (1m), Stripped leads, 1 1/2" (1" insulated singles, 1.2" bare)  
Click to expand/minimize a list of what others bought with the SA1-RTD-80  SA1-RTD-80 2 weeks   182.00    3-wire Pt100, 80 Inches (2m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)  
Click to expand/minimize a list of what others bought with the SA1-RTD-80-SB  SA1-RTD-80-SB 6 weeks   232.00    3-wire Pt100, 80 Inches with SS Over braiding 2m (80 in), Stripped leads, 1 1/2" (1" insulated singles, 1.2" bare)  
    SA1-RTD-120-SB    Consult sales   3-wire Pt100, 120 Inches with SS Over braiding (3m), Stripped leads, 1 1/2" (1" insulated singles, 1.2" bare)  
Click to expand/minimize a list of what others bought with the SA1-RTD-120  SA1-RTD-120 6 weeks   203.00    3-wire Pt100, 120 Inches (3m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)  
Click to expand/minimize a list of what others bought with the SA1-RTD-MTP  SA1-RTD-MTP 6 weeks   184.00    3-wire Pt100, 40 Inches (1m), 'MTP' style miniature flat 3-pin connector  
    SA1-RTD-80-MTP 6 weeks   216.00    3-wire Pt100, 80 Inches (2m), 'MTP' style miniature flat 3-pin connector  
    SA1-RTD-120-MTP 6 weeks   225.00    3-wire Pt100, 120 Inches (3m), 'MTP' style miniature flat 3-pin connector  
Click to expand/minimize a list of what others bought with the SA1-RTD-4W  SA1-RTD-4W 2 weeks   178.00    4-wire Pt100, 40 Inches (1m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)  
Click to expand/minimize a list of what others bought with the SA1-RTD-4W-80  SA1-RTD-4W-80 2 weeks   199.00    4-wire Pt100, 80 Inches (2m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)  
Click to expand/minimize a list of what others bought with the SA1-RTD-4W-120  SA1-RTD-4W-120 6 weeks   219.00    4-wire Pt100, 120 Inches (3m), Stripped leads, 1 1/2' (1' insulated singles, 1.2' bare)  
    SA1-RTD-4W-TA4F 6 weeks   238.00    4-wire Pt100, 40 Inches (1 m), 'TA4F' style round audio connector  
    SA1-RTD-4W-80-TA4F 2 weeks   245.00    4-wire Pt100, 80 Inches (2 m), 'TA4F' style round audio connector  
    SA1-RTD-4W-120-TA4F 6 weeks   281.00    4-wire Pt100, 120 Inches (1 m), 'TA4F' style round audio connector  
 Accessories
Click to expand/minimize a list of what others bought with the 450-APT  450-APT Consult Sales   805.00    Handheld thermometer, RTD input  
Click to expand/minimize a list of what others bought with the HH804  HH804 2 weeks   254.00    Handheld, Dual Input, Pt3926, Pt3916 and Pt385 RTD Thermometer, Min/Max/Avg, Rel, Hold functions, Accuracy: ± 0.05%; Includes male Mini Din mating connectors  
Click to expand/minimize a list of what others bought with the TA4F  TA4F 2 weeks   25.50    Cord Plug, Female, Max Cable Diameter (mm/in) 2.9 (0.114), No. Pins at Contact 4  
    SA1-RTD-4W-120-SB 6 weeks   280.00    Surface RTD, 4 wire, 3m (120 in), steel braid  
    SA1-RTD-ROHS 2 weeks   171.00    Surface RTD, 3 wire, 1m (40 in)  
All dollar amounts on this site are shown in Singapore currency.

 Note: For special lengths of lead wire, add $2.25/ft. For an SA1-RTD with TA4F connector installed (SA1-RTD-4W-TA4F), $73.00; SA1-RTD-4W-80-TA4F, $80.50; SA1-RTD-4W-120-TA4F, $88.00. For more information, see the spec sheet or contact Sales.


(OPTIONS SHOWN IN THIS "NOTE" ABOVE ARE PRICED IN US$)
 Ordering Example: (1) SA1-RTD-80-MTP Class A, surface-mount Pt100 sensor, 3-wire leads, 2 m (80'') lead-wire length with a miniature 3-pin MTP connector Class A, surface-mount RTD sensor, 4 wire leads, 2 m (80'') lead-wire length with a 4-pin, $216.00
 Part Number Builder
(1) (2) (3) (4)   
S
S
A
A
1
1
-
-
R
R
T
T
D
D
Qty:

Option Descriptions
(1) Wire Style
  Select
Nothing(leave field blank) for 3-Wire
-4W for 4-Wire
(2) Wire Length
  Select
Nothing(leave field blank) for 1 m (40 in)
-80 for 2 m (80 in)
-120 for 3 m (120 in)
(3) Cold End Termination
  Select
Nothing(leave field blank) for Stripped leads 1 1/2 (1 in insulated singles 1/2 in bare)
-MTP for MTP style miniature flat 3-pin connector
-TA4F for TA4F Connector. Pins 1 and 2 common 3 and 4 common
(4) Additional Option
  Select
Nothing(leave field blank) for None
-SB for stainless steel overbraid
 NOTE: All combinations may not be valid, check spec sheet for valid part numbers.


 Related Links - Related Products
 Related Products
TA3 and TA4 TA3 and TA4:
Miniature Connectors for RTD's and Thermistors Series "T"
MTP Series MTP Series:
3-Prong Mini flat pin Connector for Thermocouple, RTD and 3-Wire Thermistor
HH500 Series HH500 Series:
Handheld Digital Thermometers
HH200A Series HH200A Series:
Handheld Digital Thermometers
OMEGABOND® Air Set Cement Series OMEGABOND® Air Set Cement Series:
High Temperature Cements
   
Keywords:, metal electronic enclosure metal electronic enclosures waterproof electronic enclosure weatherproof enclosure