The FMG600 Series
electromagnetic flow meters
are designed for
measurement of conductive
liquids. The FMG600 magmeters have no moving parts
and a PTFE lining, they can
handle applications involving
wastewater, pulp, food, and
slurries. Standard outputs include
analog, frequency, and RS485
communications. Optional sanitary
tri-clamp mounting allows use of the
FMG600 flow meters in applications
not previously open to magmeters.
Local- and remote-display models
are available.
NOTE: HEAVY WEIGHT - NO UPS - MOTOR FREIGHT ONLY!!! OVERWEIGHT SHIPPING CHARGES WILL APPLY FOR THIS PRODUCT. IF ORDERED ON-LINE INTERNET SALES WILL CONTACT YOU AFTER ORDER PLACEMENT UNLESS YOU OPT TO CHARGE FREIGHT TO YOUR CARRIER ACCOUNT.
SPECIFICATIONS Flange Sizes: 150# ANSI: 19 to 305 mm (¾ to 12") Sanitary Tri-Clamp: 13 to 305 mm (½ to 12") Maximum Pressure: 145 psi Minimum Conductivity: 20 µS Electrode Material: Hastelloy C4 (standard), tantalum (TGE optional) Environmental Temperature: -5 to 55°C (23 to 131°F) Sensor Lining: PTFE Electronics Housing: Local or remote (optional) Liquid Temperature: 0 to 50°C (32 to 122°F) STD, 0 to 150°C (32 to 302°F) with remote electronics Empty Pipe Alarm: 2" and larger sizes (EPD optional) Accuracy: ±0.5% from 5 to 100% Qs, ±1% from 1 to 5% Qs Range: 0.1 to 10 m/s (0.328 to 32.81 fps) Outputs: Adjustable from 0.1 to 1000 gallons/pulse Current: 4 to 20 mA with galvanic isolation Frequency: 0 to 1000 Hz with galvanic isolation Communications: RS485 Power: 24 Vdc, 115/230 Vac switchable (optional) Consumption: 15 VA Protection: IP67 Storage Temperature and Humidity: -10 to 70°C (14 to 158°F) at max; relative humidity 70%
† All dollar amounts on this site are shown in Singapore currency.
Note: Unit comes with complete operator’s manual and 3-point NIST calibration certificate
Part Number Builder
Option Descriptions
(1)
Size mm(inch) & Max GPM
Select 01 for 15 (1/2 inch) and 11 GPM 02 for 20 (3/4 inch) and 52 GPM 02 for 20 (3/4 inch) and 31 GPM (-S and -S-R Series Models) 03 for 25 (1 in) and 79 GPM 03 for 25 (1 in) and 61 GPM (-S and -S-R Models) 04 for 32 (1 1/4 inch) and 132 GPM 04 for 32 (1 1/4 inch) and 96 GPM (-S and -S-R Models) 05 for 40 (1 1/2 inch) 198 GPM 05 for 40 (1 1/2 inch) and 151 GPM (-S and -S-R Models) 06 for 50 (2 inch) and 317 GPM 06 for 50 (2 inch) and 281 GPM (-S and -S-R Models) 07 for 65 (2 1/2 inch) and 528 GPM 07 for 65 (2 1/2inch) and 451 GPM (-S and -S-R Models) 08 for 80 (3 inch) and 793 GPM 09 for 100 (4 inch) and 1233 GPM 10 for 125 (5 inch) and 1893 GPM 11 for 150 (6 inch) and 2862 GPM 12 for 200 (8 inch) and 5063 GPM 13 for 250 (10 inch) and 7925 GPM 14 for 300 (12 inch) and 11100 GPM
(2)
Magmeter
Select Nothing(leave field blank) for #150 ANSI flange magmeter -S for SS sanitary mount magmeter
(3)
Display
Select Nothing(leave field blank) for Local display -R for Remote display
(4)
Vac Power
Select Nothing(leave field blank) for 24 Vdc -VAC for Units with switchable 115/230 Vac power
(5)
Electrode
Select Nothing(leave field blank) for None -TE for Units with tantalum electrodes -TGE for Third tantalum grounding electrode -HGE for Third hastelloy grounding electrode
(6)
Calibration
Select Nothing(leave field blank) for None -NIST4 for 4-point NIST calibration -NIST10 for 10-point NIST calibration
(7)
Empty Pipe Detection
Select Nothing(leave field blank) for None -EPD for Empty pipe detection on units 2 inch and larger
(8)
Batching Option
Select Nothing(leave field blank) for None -B for Units with a batching option
NOTE: All combinations may not be valid, check spec sheet for valid part numbers.