The LDP63200 series has been discontinued. Please see the ILD-UTP as a possible alternative or contact our sales department.
The LDP63200 Series are versatile
large display meters available as a
DC volt, current, or process meter
with scaling, serial communications
and dual relay outputs. The 5-digit
displays are available in either
57 mm (2.25") or 101 mm (4") high
red LED digits with adjustable
display intensities. The 57 mm
(2.25") high models are readable up
to 39.6 m (130'). The 101 mm (4")
high models are readable up to
54.9 m (180'). Both versions are
constructed of a NEMA 4X (IP65)
enclosure in light weight aluminum.
All models also come with dual
Form C relay outputs and RS232/
RS485 serial communications.
SPECIFICATIONS Display: 5-digit, 57 mm (2.25") or 101 mm (4") intensity adjustable red LED (-99999 to 99999) Power Requirements AC Power: 50 to 250 Vac 50/60 Hz, 26 VA DC Power: 21.6 to 250 Vdc, 11 W DC Out: ±24 Vdc at 100 mA if input voltage is greater than 50 Vac/Vdc ±24 Vdc at 50 mA if input voltage is less than 50 Vdc Isolation: 2300 Vrms for 1 min to all inputs and outputs Input Ranges: Jumper selectable A/D Converter: 16 bit resolution A/D Conversion Rate: 6 readings/sec Display Response Time: 500 msec min User Input Software: Selectable pull-up (8.6 K) or pull-down resistor (3.9 K) that determines active high or active low input logic. Trigger levels: VIL = 1.0V max; VIH = 2.4V min; VMAX = 28 Vdc Response Time: 5 msec typ; 50 msec debounce (activation and release) Communications Type: RS485 or RS232 Isolation To Sensor and User Input Commons: 500 Vrms for 1 min Working Voltage: 50V not isolated from all other commons Data: 7/8 bits Parity: No, odd or even Baud Rate: 300 to 38.4 K Bus Address: Selectable 0 to 99, max 32 m (105') per line (RS485) Memory: Nonvolatile EEPROM retains all programming parameters and max/min values when power is remove Output Type: Single FORM-C relay Isolation to Sensor and User Input Commons: 1400 Vrms for 1 min Working Voltage: 150 Vrms Contact Rating: Resistive Load: 5 amps @ 120/240 Vac or 28 Vdc Inductive Load: 1/8 H.P. @ 120 Vac Life Expectancy: 100,000 min operations Response Time Turn On: 4 msec max Turn Off: 4 msec max Environmental Conditions Operating Temperature: 0 to 65°C (32 to 149ºF) Storage Temperature: -40 to 70°C (-40 to 158ºF) Operating and Storage Humidity: 0 to 85% max RH (non-condensing) Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z direction for 1.5 hours, 2 g’s (1 g relay) Shock According to IEC 68-2-27: Operational 30 g’s (10 g relay), 11 msec in 3 directions Altitude: Up to 2000 m (6561') Connections: Internal removable terminal blocks Wire Strip Length: 10 mm (0.4") Wire Gage: 24-12 AWG copper wire, 90°C rated insulation only Torque: 5.3 inch-lbs (0.6 N-m) max Cable Diameter: Outside diameter must be 4.6 mm (0.181") to 7.9 mm (0.312") to maintain NEMA 4 (IP65) rating of cord grips Construction: Aluminum enclosure, steel side panels with textured black polyurethane paint for scratch and corrosion resistance protection. Meets NEMA 4X (IP65) specifications. Installation Category II, pollution degree 2 Weight: LDP63200-2: 2.04 kg (4.5 lb) LDP63200-4: 4.76 kg (10.5 lb)
† All prices on this site are shown in Thai Baht. Note: Comes complete with operator’s manual.