Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Malaysia: 1800 88 3496
International+65 6415 5353

DIN Rail Mount Circuit Breakers

R Series UL1077 Supplementary Protectors

Circuit Breakers, UL 1077 Supplementary Protectors | R Series UL1077 Supplementary Protectors

Circuit Breakers, UL 1077 Supplementary Protectors

SGD116.00 AU-3B30UR

CE
  • DIN Rail Mounted
  • 17.5 mm (0.69") Width per Pole
  • Thermal Magnetic Overcurrent Protection
  • 0.5 - 60 A, 480Y/277 Vac, 50/60 Hz
  • 10 kA Short Circuit Interrupting Capacity
  • UL Recognized E137915
  • Dual Connection Terminals, Box Clamp and Ring Tongue/Forked Terminals
  • Marking Area with Clear Cover
Power Products - View related products

Description

While UL489 branch circuit breakers protect feeder or branch circuits, R Series UL1077 supplementary protectors are made to trip faster than a standard UL489 circuit breaker, therefore providing additional protection for specific devices. Supplementary protectors provide critical protection in applications where branch circuit protection is not required, or is already provided by a separate device.
R Series supplementary protectors are available in one, two, and three-pole configurations and up to 20 different current ratings from 0.5A to 60A and can safely be used in applications up to 480Y/277 Vac with a 10 kA short circuit withstand Rating.

Three different trip characteristics, including B, C and D curves, give you the ability to configure the exact protection scheme you require.

B-Trip Protectors
Include business equipment, wiring protection, lighting, appliances, control circuits and some electronic applications. Relatively long thermal trip delay but low magnetic trip point.

C-Trip Protectors
Include lighting, wiring protection, appliances, business equipment, and control circuit applications. Relatively long thermal trip delay and medium magnetic trip point.

D-Trip Protectors
Include control transformers, power supplies and reactive loads. Relatively long thermal trip delay and very high magnetic trip point.

Features Provided by the Different Types of Circuit Breakers
UL1077 Recognized Supplementry Protectors
    Overload Protection

UL508 Listed Manual Motor Controllers
    Overload Protection
    Switching Function
    Disconnect Function

UL489 Miniature Molded Case Circuit Breakers
    Overload Protection
    Switching Function
    Disconnect Function
    Short Circuit Protection

Specifications
Voltage Rating: 480Y/277 Vac
Short Circuit Withstand Rating (UL - Ratings):
    0.5-10A (RC): 10kA with no back-up fuse
    12-60A (RC): 10kA with UL-listed Class J back-up fuse; 5kA with no back-up fuse
Calibration Temperature: 30°C (86°F)
Operating Temperature: -25 to 55°C (-13 to 131°F)
Storage Temperature: -40 to 70°C (-40 to 158°F)
Terminal Size Acceptability:
    Top: 18-3 AWG
    Bottom: 18-2 AWG (line/load reversible)
Tightening Torque (min/max): 17.7/25 lb-in. (2/2.8 Nm)
Terminal Protection Degree: IP20
Vibration Resistance: ≥15g
Dimensions:
    Height: 89.3 mm (3.51")
    Width:
      One Pole: 17.5 mm (0.69")
      2 Pole: 35 mm (1.38")
      3 Pole: 52.5 mm (2.07")
Depth:68.4 mm (2.69") from DIN rail

Use the "Part Number Builder" below for product selection.
(Specify Model Number)
Part Number/Desc.
Qty
Description
AU-1B5UR
SGD38.50
Availability: 14 weeks
 
1-pole supplementary protector, 5.0A, rated voltage 277V AC, B-curve
AU-2C10UR
SGD81.00
Availability: 1 week
 
2-pole supplementary protector, 10A, rated voltage 480Y/277V AC, C-curve
AU-3D20UR
SGD115.82
Availability: 14 weeks
 
3-pole supplementary protector, 20A, rated voltage 480Y/277V AC, D-curve
Accessories for UL1077 Supplementary Protectors
AU-N63UM
SGD75.00
Availability: 14 weeks
 
Neutral pole for UL1077 circuit breaker.
AU-H10UM
SGD58.00
Availability: 14 weeks
 
1 Auxiliary contact, normally open
AU-H11UM
SGD64.00
Availability: 14 weeks
 
2 Auxiliary contacts, 1 NO & 1 NC
AU-H10UM
SGD58.00
Availability: 14 weeks
 
3 Auxiliary contacts, 1 NO & 2 NC
AU-H21UM
SGD81.00
Availability: 14 weeks
 
3 Auxiliary contacts, 2 NO & 1 NC
AU-FA12UM
Consult Sales  
Availability: 
 
 
12 V AC/DC shunt trip, 1.3A
AU-FA24UM
Consult Sales  
Availability: 
 
 
24 V AC/DC shunt trip, 0.6A
AU-FA48UM
Consult Sales  
Availability: 
 
 
48 V AC/DC shunt trip, 0.2A
AU-FA110UM
Consult Sales  
Availability: 
 
 
Shunt trip, 110-240 V AC/DC, 277 V AC , 0.25A @ 110V, 0.5A @ 240V, 0.58A @ 277V
AU-UA120UM
SGD175.00
Availability: 10 weeks
 
Undervoltage Trip, 120V AC, 60 Hz.(UL Pending)
AU-N63UM
SGD75.00
Availability: 14 weeks
 
Neutral pole for UL1077 circuit breaker.
AU-H10UM
SGD58.00
Availability: 14 weeks
 
1 Auxiliary contact, normally open
AU-H11UM
SGD64.00
Availability: 14 weeks
 
2 Auxiliary contacts, 1 NO & 1 NC
All prices on this site are shown in Singapore Dollars.
Note: (*) Insert “B” for b-curve, “C” for c-curve and “D” for d-curve.

Option Descriptions:


(1) Poles select from:
-1 for 1 Pole
-2 for 2 Poles
-3 for 3 Poles

(2) Curve Type select from:
B for b-curve
C for c-curve
D for d-curve

(3) Rated Current select from:
05UR for 0.5A
1UR for 1.0A
2UR for 2.0A
3UR for 3.0A
4UR for 4.0A
5UR for 5.0A
6UR for 6.0A
8UR for 8.0A
10UR for 10A
12UR for 12A
13UR for 13A
15UR for 15A
16UR for 16A
20UR for 20A
25UR for 25A
30UR for 30A
32UR for 32A
40UR for 40A
50UR for 50A
60UR for 60A
63UR for 63A
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.