LC414 Series
Base Mount Compression Load Cells
Description
This item is discontinued.
The LC414 is designed for rugged industrial weighing applications. Built-in overload stops and the ability to withstand up to 12.7 mm (0.5") off center loading allows the LC414 to survive in applications when the load cells would not. The all stainless steel construction and sealed connector provides a load cell that can withstand the harsh environments found in most industrial applications. The integral mounting plate with mounting holes makes installation fast and secure.
SPECIFICATIONS
Excitation: 10V AC or DC, 15V max
Output: 3 mV/V ±0.25%
Calibration: 5 points in compression 0%, 50%, 100%, 50%, 0% capacity
Linearity: ±0.05%
Hysteresis: ±0.05%
Repeatability: ±0.02%
Max Off Center Load: 12.7 mm (0.5") Change in Output Due to 12.7 mm
(0.5") Off Center Loading: 0.5% load
Operating Temperature: -18 to 71°C (0 to 150°F)
Compensated Temperature: -9.4 to 46°C (15 to 115°F)
Thermal Effects
Span: ±0.0014% rdg/°C rated output
Zero: ±0.0023% FS/°C rated output
Safe Overload: 150% capacity
Ultimate Overload: 225% capacity
Bridge Resistance: 350 O nominal
Protection Level: IP66
Electrical Connection: 6 m (20')
Insulation Resistance: 5000 Meg O
Span Adjustment: ±2.5%
Mating Connector: MS3106F-14S-5S, sold separately
Construction: 17-4 pH stainless steel
Connector Wiring: A = (-) Output B = (-) Excitation C = Ground D = (+) Output E = (+) Excitation
† All prices on this site are shown in Philippine Pesos.
Ordering Example: (1) MS3106F-14S-5S load cell mating connector (sold separately), PHP14,475.00