Toll-Free in Philippines: 1 800 8908 8267 | 1 800 1441 0877
International+65 6415 5353

Capacitance Continuous Level Measurement Probes

LV3000 and LV4000 Series

Capacitance Continuous Level Measurement Probes and Switch | LV3000 and LV4000 Series

Capacitance Continuous Level Measurement Probes and Switch

See All Models Below

CE
  • Can Operate at High Temperatures and Pressure
  • Unaffected by Coating Media or Aggressive Products
  • Accurate and Reliable Measurement
  • Easy Economical Installation
  • Rugged Construction
  • No Moving Parts
  • Compatible with Both Conductive and Non-Conductive Media
  • Wide Range of Applications/Industries (e.g., Water, Oils, Corrosives)
Level Switches & Transmitters - View related products

Description

The LV3000/LV4000 Series continuous level measurement probes are flexible, cost-effective solutions for applications involving liquids, pastes, and some solids. The built-in (one-piece) electronic module provides a 4 to 20 mA output (2-wire) signal that is proportional to the process level. Zero and span adjustment helps account for various media, tank dimensions, rod lengths, and positions of installation.

OMEGA™ offers these probes in several different models. The user must choose the probe that suits his or her application and install it in the proper location. When submerged, the probe must be able to produce enough capacitance variance. The probe’s success depends on these important factors:
A) Conductive materials can cause a short circuit between a bare stainless steel probe and the tank wall. For this situation, we recommend using PTFE sleeving on the rod surface.
B) Material buildup affects the accuracy of RF capacitive measurements. Additional adjustment to the probe’s sensitivity is therefore recommended.

Housings must be compatible with the requirements for hazardous, washdown, wet, or dusty environments. For explosion-proof environments, the housing may need to be certified. In addition, the active probe might need to be intrinsically safe or have an intrinsic safety barrier.

The electronic circuitry of the probe performs several functions, such as rectifying and filtering the incoming power, generating the radio frequency signal, and measuring the changes in current flow.

SPECIFICATIONS (LV3000 SERIES)
Accuracy:
0.5%
Repeatability: ±1 mm
Level Indication: Bar graph, 0 to 1000%
Process Connection: ¾ to 1½ NPT, tri-clamp or flange
Wetted Material: 316 SS or PTFE
Enclosure Material: Aluminum die cast
Max Pressure: 290 psi (20 bar)
Operating Temperature: -10 to 120°C (14 to 248°F)
Class Protection:
    LV3000: NEMA 4 (IP65)
    LVCN410: IP40
Max Probe Length: 1.8 m (6')
Dimensions:
    Aluminum Die-Cast Head: 89 W x 108 mm H (3.5 x 4¼")
    Diameter of Probe: 16 mm (5/8")
Electrical Connection: Cable gland with ½ NPT conduit
Note: The LV3000 Series probes require a LVCN400 Series controller.

SPECIFICATIONS (LV4000 SERIES)
Accuracy:
0.5%
Repeatability: ±1 mm
Operating Voltage: 12 to 30 Vdc
Adjustment: Zero and span (potentiometer)
Range of Sensitivity: 100 to 5500 pF
Frequency Oscillation: 400 kHz
Output: 4 to 20 mA (2-wire)
Process Connection: ¾ to 1½ NPT, tri-clamp or flange
Wetted Material: 316 SS or PTFE
Enclosure Material: Glass-filled nylon or aluminum die cast
Max Pressure: 290 psi (20 bar)
Operating Temperature: -10 to 120°C (14 to 248°F)
Class Protection: NEMA 4 (IP65)
Max Probe Length: 1.8 m (6')
Dimensions:
    Nylon Head: 89 W x 64 mm H (3.5 x 2.5")
    Aluminum Die-Cast Head: 89 W x 108 mm H (3.5 x 4.25")
    Diameter of Probe: 16 mm (58")
Electrical Connection: Cable gland with ½ NPT conduit
Note: The LV4000 Series probes require a galvanic isolator, LI-420.

SPECIFICATIONS (LI-420)
Input Current from the Evaluation Instrument:
4 to 20 mA
Input Voltage: 22 to 24 Vdc
Output Current: 4 to 20 mA
Output Voltage to the Transducer at 20 mA: 12.5 V
Output Voltage to the Transducer at 4 mA: 15.5 V
Resistance per Conductor: 15 Ω
Testing Voltage Input/output circuit: 2000 Veff
Domestic Current Demand: 300 ±60 µA
Ambient Temperature: -20 to 70°C (-4 to 158°F)
Enclosure Dimensions: 44 W x 82 H x 110 mm L (1¾ x 3¼ x 438)

SPECIFICATIONS (LVCN410 SERIES)
Operating Voltage:
24 Vdc, 110 or 240 Vac (50/60 Hz)
Current Consumption: 4 mA
Adjustment: Zero and span (potentiometer) and 2 switch point (potentiometer)
Range of Sensitivity: 50 to 1000 pF
Output: 4 to 20 mA and 2-relay SPDT
LVCN411/LVCN412: 73 W x 110 H x 110 mm L (278 x 438 x 438")

(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Qty
Description
  
LV4012-38
PHP107,510.00
Availability: 7 weeks
 
96.5 cm (38") long probe with 3/4 NPT connection, with aluminum die cast head with 1/2 NPT conduit entry
  
LV4042-60
PHP125,365.00
Availability: 7 weeks
 
152.4 (60") long probe with 1 1/2" Tri-Grip™ connection, with aluminum die cast head with 1/2 NPT conduit entry
  
LV4111-24
PHP92,184.90
Availability: 4 weeks
 
60 cm (24") long probe with 3/4" NPT connection, with PTFE coating and nylon head
  
LV4121-36
PHP91,415.00
Availability: 7 weeks
 
90 cm (36") long probe with 1" NPT connection, with PTFE coating and nylon head
  
LV4121-48
PHP99,025.00
Availability: 7 weeks
 
1.2 m (4') long probe with 1" NPT connection, with PTFE coating and nylon head
  
LV4121-60
PHP100,960.00
Availability: 7 weeks
 
1.5 m (5') long probe with 1" NPT connection, with PTFE coating and nylon head
  
LV3123-48-HT
Consult Sales  
Availability: 
 
 
Remote electronics required LVCN410 Series 1.2 m (4') long probe with 1 NPT connection, with PTFE coating and aluminum die cast head, 177°C (350°F)
  
LV3125-48-HT
PHP303,900.00
Availability: 7 weeks
 
Remote electronics required LVCN410 Series 1.2 m (4') long probe with 1 NPT connection, with PTFE coating and aluminum die cast head, 177°C (350°F)
  
LVCN411
PHP65,270.00
Availability: 1 week
 
24 Vdc powered controller with relay and 4 to 20 mA output for LV3000 Series only
  
LVCN412
PHP66,245.00
Availability: 1 week
 
115 Vac powered controller with relay and 4 to 20 mA output for LV3000 Series only
Accessories
  
CNI16D33
PHP25,945.00
Availability: 7 weeks
 
1/16 DIN Dual Display with two 3 A relays and 24 Vdc Excitation
TX4-100
TX4-100
PHP3,232.55
Availability: 1 week
 
30 m (100') spool of 4 conductor wire
FPW-15
FPW-15
Consult Sales  
Availability: 
 
 
15 Vdc power supply
  
LI-420
PHP35,195.00
Availability: 7 weeks
 
Loop isolator

Order By Part Number

Part Number
Qty
Part Number
Qty


All prices on this site are shown in Philippine Pesos.
Note: Comes complete with operator’s manual.

LV4000 Series length is not recommended below 24" due to dielectric strength.

For High Temperature PTFE Sleeving 200°C (392°F), add suffix "-HTPTFE" to model number, add $150 per unit and $660 per foot to price.


Ordering Example: (1) LV4111-24 60 cm (24, PHP92,184.90

Option Descriptions:


(1) Capacitance System select from:
4 for standard capacitance system
3 for remote capacitance system

(2) Insulation Connection select from:
0 for 316 SS rod
1 for ECTFE/ETFE sleeve

(3) Process Connection select from:
1 for 3/4 NPT thread
2 for 1 NPT thread
3 for 1.5 NPT thread
4 for 1.5 in Tri-Grip
5 for 2 in ANSI flange 15016 316 SS

(4) Enclosure select from:
1 for glass-filled nylon with 1/2 NPT conduit entry and cable gland
2 for aluminum die cast with 1/2 NPT conduit entry-LV4000
3 for aluminum die cast with cable gland entry-LV4000
4 for aluminum die cast with 1/2 NPT conduit entry-LV3000
5 for aluminum die cast with cable gland entry-LV3000

(5) Length select from:
L for length in inches -72 inches max
Note: All combinations may not be valid, check spec sheet for valid part numbers.

Product Manuals:

Download LV4000 Series - Continuous Level Measurement Probes
Download LVCN410 and LV3000 Series - Continuous Level Measurement
We noticed you are from the US. Visit your local site for regional offers and live support.