Cart  |  Contact  |  Help  |  seainfo@dwyeromega.com  | 
Toll-Free in Thailand: 001 800 441 0237
International+65 6415 5353

Multi-Functional Handheld Calibrator - Discontinued

CA150

Multi-Functional Handheld Calibrator | CA150

Multi-Functional Handheld Calibrator

See All Models Below

CE
  • Highly Accurate Within 0.02% of the DC Voltage Range for Source and Measure
  • Source and Measurement can be Performed Simultaneously
  • Vertical Body with Large Screen Display
  • Loop Power Supply
  • Sink Function
  • 3 Sweep Function Outputs (Step Sweep, Linear Sweep, Program Sweep)

Description

The CA150 has been discontinued. For a potential replacement, please see our full offering of multifunction calibrators here.

Vertical Handheld Calibrator
Easy-to-hold vertical body is designed to make it intuitively easy to operate, as individual functions are accessed directly by pressing assigned keys. The main body case (sold separately) is designed to make it easy to hold the CA150 in one hand.
Simultaneous Source and Measurement for Process Devices
In conventional calibration applications, multiple devices such as a standard generator, dial resistor and multimeter were required. Now with a single CA150 unit, it is possible to perform operation check at regular inspection and maintenance of thermocouples, RTDs and instruments, as well as maintenance and equipment diagnosis of process devices such as transmitters, thermostats and signal converters.
Loop Power Supply Function
It is possible to measure generated current signals while supplying loop power 24 Vdc from a two-wire type transmitter (up to 22 mA DC).
Highly Accurate and Multi-Functional Source and Measurement
High Accuracy: 0.02% for the source unit and 0.02% for the measurement unit Source and Measurement Functions: DCV voltage, DC mA, ohm, Frequency and temperature (thermocouple, RTD) and 24 Vdc power supply function for transmitters
Memory Functions: Setting Memory
This function saves/loads setting conditions. Up to 21 data items can be stored. Settings for (source/ measurement) functions, ranges, generated values/measured values as well as setting mode conditions can be stored.
Data Memory
This function saves source and measure values displayed. Up to 100 data items can be stored. Storage date/time, (source/ measurement) functions, ranges and generated values/measured values can be stored. Stored data can be checked on the display of the main unit as well as via communication.

SPECIFICATIONS
External Dimensions:
Approx 251 H x 124 L x 70 mm W (10 x 5 x 3")
Weight: Approx 1000 g (oz)
(Specify Model Number)
Part Number/Desc.
Qty
Description
CA150
Consult Sales  
Availability: 
 
 
Handheld calibrator
CA150-NIST
Consult Sales  
Availability: 
 
 
Calibrator with 3-point calibration
Accessories
CA150-AC-ADAP
Consult Sales  
Availability: 
 
 
Power cord ul/csa for CA150
CA150-ACC-CASE
Consult Sales  
Availability: 
 
 
Accessory case for CA150
CA150-CARRY-CASE
Consult Sales  
Availability: 
 
 
Carrying case for CA150
CA150-FER-CORE
Consult Sales  
Availability: 
 
 
Ferrite core for CA150
CA150-FUSE-SET
Consult Sales  
Availability: 
 
 
Fuse set CA150 set of 10 fuses
CA150-MEAS-LEAD
Consult Sales  
Availability: 
 
 
Measurement lead cables for CA150
CA150-NIMH-BAT
Consult Sales  
Availability: 
 
 
NiMH battery for CA150
CA150-RJ-SENS
Consult Sales  
Availability: 
 
 
Reference junction sensor for CA150
CA150-SOURCE-LEAD
Consult Sales  
Availability: 
 
 
Lead cable for generation
CA150-STRAP-CASE
Consult Sales  
Availability: 
 
 
Main body case for CA150
CA150-TERM-ADAP
Consult Sales  
Availability: 
 
 
Terminal adaptor for CA150
All prices on this site are shown in Thai Baht.
Note: Comes with complete instruction manual, 6 “AA” batteries, carrying case, leads and terminal adaptor. (Temperature display default is °C, may be changed to °F - see page 12-1 of manual.)
We noticed you are from the US. Visit your local site for regional offers and live support.