LC704_LC714
High Capacity Load Cells | Tension Link Load Cells
Description
This item is discontinued.
OMEGA’s LC704/714 Series
tension link load cells have a male to
female thread connection; LC704
with a 1.8 m (6') cable, and
LC714 with an integral connector.
Both series are comprised of
all stainless steel. Applications
include cables on cranes, support
rods in architectural designs,
engine test beds, suspension
bridges and industrial weighing.
Specifications
Output: 2 mV/V ±0.25 % FSO
Excitation: 10 Vdc (15V max)
Linearity: ±0.10% FSO
Hysteresis: ±0.10% FSO
Repeatability: ±0.05% FSO
Zero Balance: ±1.0% FSO
Operating Temp Range: -34 to 121°C (-30 to 250°F)
Compensated Temp Range:
16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ±0.009% FSO/°C (±0.005%FSO/°F)
Span: ±0.009% FSO/°C (±0.005% FSO/°F)
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Bridge Resistance: 350 Ω
Construction: Stainless steel
Electrical:
LC704: 1.8 m (6') 4-conductor cable
LC714: DT02H-10-6P (or equiv.)
Protection Class: IP67
Mating Connector: PT06F10-6S, (sold separately)
Calibration: Calibrated in tension*
* ≥100,000 lb calibrated in compression.
For calibrations ≥300,000 lb, add suffix
“-FS” and consult Sales for price and delivery.
† All prices on this site are shown in Thai Baht.
Note: Comes complete with 5-point NIST-traceable calibration and 59 kO shunt data.
* 4-digit meter, counts by 10.
To order additional cable add length, in feet, to the end of the model number, additional price per foot over 1.8 m (6').
Ordering Example: (1) PT06F10-6S Mating connector (sold separately), THB1,610.98
Option Descriptions:
(1)
Cable or Connector select from:704 for Cable style
714 for Connector style
(2)
Load Range select from:5K for 0-5000 lb range
10K for 0-10000 lb range
20K for 0-20000 lb range
30K for 0-30000 lb range
50K for 0-50000 lb range
100K for 0-100000 lb range
150K for 0-150000 lb range
200K for 0-200000 lb range
300K for 0-300000 lb range
500K for 0-500000 lb range
1M for 0-1000000 lb range
Note: All combinations may not be valid, check spec sheet for valid part numbers.