Cart  |  Contact  |  Help  |  info@sea.omega.com  | 
Toll-Free in Malaysia: 1800 88 3496
International+65 6415 5353

iServer 2 - Virtual Chart Recorder

IS2-THB-ST

iServer 2 - Virtual Chart Recorder | IS2-THB-ST

iServer 2 - Virtual Chart Recorder

See All Models Below

CE
  • Built-in Webserver with Live Charting with Display (Select Models)
  • Internal Data Storage up to 10 Years
  • Battery Backup
  • Uses Omega Link Smart Probes
USB, RS232, RS485 and Ethernet Data Acquisition Systems - View related products

Description

iServer 2: Introduction

The iServer 2 virtual chart recorder offers an intuitive way to collect and display live sensor readings through a web-based user interface or by integrating the device into an existing Omega Link Ecosystem.


The iServer 2 probe variant is packaged in a rugged, compact, stainless-steel housing designed for industrial applications and comes in variants that support different Omega Link Smart Probe types:


M12 Smart Probe Variants
Part Number iS2-THB-B iS2-THB-STiS2-THB-DP
Screen No Display DisplayDisplay
Sensor Type ProbeProbeProbe
I/ONo Relay, No DIORelay, DIORelay, DIO
PowerAC to 12 VDC AdaptorAC to 12 VDC AdaptorAC to 12 VDC Adaptor,PoE


Web UI and Live Charting

The iServer 2 web UI offers a myriad or configurable features to ensure the device operates at the preferred user preferences. Configurable features include selective data extraction, measurement and device traceability, local alarms, and adaptive transmission rates. Live charting provides real-time readings of probes attached to the iServer 2 unit.


Edge Control and Built in I/O

The iServer 2 features 2 configurable digital I/O and relay ports(Standard and Deluxe models only). These can be used for a myriad of applications including driving relays or physical alarms. The iServer 2 can also be utilized as an edge controller, with autonomous independent decision-making capabilities to generate local alarms or provide control outputs based on sensor inputs.


Alarms and Notifications

A fully configurable alarm system is available in the web UI to create events and thresholds that will trigger a notification should those scenarios be met. A modern notification system allows users to be notified via email or text.


Easy Setup

The iServer 2 is simple to install and use, and features Omega’s iServer technology that requires no special software except a web browser. The iServer 2 connects to an Ethernet Network with a standard RJ45 connector and uses TCP/IP or Modbus TCP protocols to communicate. It is easily configured with a simple menu using a web browser and is password protected. From within an Ethernet LAN, the user simply types the hostname or IP address in any web browser, and the iServer 2 provides a webpage with the current readings.


Typical Applications

The iServer 2 is great for monitoring temperature in applications such as clean rooms, computer rooms, HVAC systems, hospitals, laboratories, semiconductor fabs, electronic assembly, warehousing, museums, manufacturing, farm animal shelters, greenhouses, pharmaceutical, food processing and storage, and many more.


Power Over Ethernet

The iS2-THB-DP variant of the iServer 2 both offer a Power over Ethernet (PoE) feature that provides the device with sufficient power to operate when connected to a PoE Injector or router that supports Power over Ethernet.


Power Failure

The iServer 2 will continue to collect data for 96-hours when powered by a standard 9 Volt alkaline backup battery (included). A failure on the Ethernet network will not interrupt data recording.


Important Note: A fully charged 9-volt battery will allow the iServer 2 to continue logging up to 10,000 data points for a period of 96 hours. When the 10,000 logged data points have been exceeded while running on the backup battery, the oldest logged data point on the Smart Probe will be overwritten starting from the oldest data point saved on the Smart Probe. A logging interval of at least 35 seconds or longer will prevent the overwriting of data during the 96-hour period the battery is in use.

Omega Link Integration

Omega Link compatible devices, such as the iServer 2, can be added to an existing Omega Link Ecosytem to provide data anytime, anywhere, through the Omega Link Cloud. The following Omega Link Smart Probes are supported:

Part Number Description
SP-003/SP-004 Temperature, Humidity, Barometric Pressure, Dewpoint, Humidex, and Heat Index Smart Probe with discrete I/O
SP-005 Temperature and RTD Smart Probe
SP-006Pressure Monitoring and Control Smart Probe
SP-010Load Cell Smart Probe
SP-014Process Monitoring Smart Probe
SP-016Heat Flux Smart Probe

View the full list of Omega Link Smart Probes.


Important Note:The use of additional Omega Link Smart Probes will require a firmware update of the Smart Probe. The iServer 2 web interface is capable of downloading and updating the firmware of any Smart Probe that is compatible with the iServer 2.

CAL-3 SKU’s

CAL-3 is available for iServer 2 M12 Models for temperature and humidity only by ordering the SKU’s below. For Barometric Pressure or additional calibration requirements, please contact Omega.

  • iS2-THB-B-CAL-3
  • iS2-THB-ST-CAL-3
  • iS2-THB-DP-CAL-3

  • Specifications

    INTERFACES

    Available input ports will vary by iServer 2 model.


    Ethernet (RJ45):1x port (Power over Ethernet available on qualifying models)
    Supported Protocols:TCP, UDP, SNMP, SNTP, ARP, ICMP, DNS, HTTP, and Telnet
    Omega Link Smart Probe: 1x M12 8-Pin port
    Digital I/O and Relays (Standard and Deluxe Models Only):Two contact inputs TTL 0.5 mA with 10k pull-up; one open collector output 150 mA @ 30 V DC
    LED Indicators: 100 BASE-T, Network Link and Activity, Internet
    Alarm I/O: Two contact inputs TTL 0.5 mA with 10k pull-up; one open collector output 150 mA @ 30 V DC
    Sample Rate: 8 samples/second max
    Memory Capacity and Sample Rate: The table below lists the lifespan of the internal storage before the 11 GB of storage is filled. Some Smart Probes come with more than one active sensor. These sensors can be individually enabled and disabled using Omega’s SYNC configuration software.

    Sample Rate4 Active Sensor
    1 second (max) 2 years
    5 seconds 12 years
    10 seconds 20 years

    Management:Device and probe configuration and monitoring through embedded WEB server
    Embedded WEB Server:Servers WEB pages containing real-time data and live updated gauge views and charts within definable time intervals

    MECHANICAL
    Dimensions of Base Device: 101.6 mm L x 155.6 mm W x 330 mm H (4 in. L x 6.13 in. W x 12.99 in. H) not including bracket and M12 connector
    Material:Stainless Steel
    Display: LCD 32 mm L x 93.5 mm W
    Weight: 655 g (1.44 lbs.), including battery

    POWER
    Power Input:9 to 12 V DC
    Consumption: 4W
    AC Power Adapter (Included) Nominal Output: 12 V DC @ 1.5 A
    Power over Ethernet: IEEE 802.3AF, 44 V - 49 V, Power Consumption under 10 W
    Input: 100 to 240 V AC, 50/60 Hz
    Back-Up Battery: 9 V DC, alkaline. 96 hours at 5 seconds recording intervals and 1 second reading

    ENVIRONMENTAL
    Operating Temperatures - iServer 2
    iServer 2 Unit:0 to 60°C (32 to 140°F)
    Battery: -18 to 55°C (-0.4 to 131°F)
    AC Power Adapter: 0 to 40°C (32 to 104°F)
    Industrial Cable: -40 to 125°C (-40 to 257°F)
    Storage Temperature: -40 to 85°C (-40 to 185°F)

    GENERAL
    Configuration: Internal Web UI
    Software: : Access web server using any modern web browser such as Chrome, Edge, or Firefox on the same local network; Firmware upgrade from Internet; Export probe data log to CSV files
    Agency Approvals: CE, UKCA, FCC (Part 15, Subpart B, Class B of the FCC rules)

    SP-003-1 PROBE ACCURACY SPECIFICATIONS(Included with iServer 2 M12 Smart Probe variants)
    Temperature Range:-40 to 85°C (-40 to 185°F)
    Accuracy at 25°C:±0.3°C (±0.6°F)
    Response Time: Less than 1 second
    Temperature Coefficient: : less than 0.01 C/C
    Repeatability: ±0.15°C

    Relative Humidity
    Accuracy at 25°C: ±2.5% (0 to 80%) non-condensing, ±3.5% (80 to 100%) non-condensing
    Hysteresis: ±0.8%
    Response Time: 8 seconds

    Barometric Pressure
    Accuracy Over Full Range: ±6 mbar from 300 to 1100 mbar
    Accuracy @ 25°C:±4 mbar from 700 to 1100 mbar

    For full SP-003-1 specifications, navigate to the full product page of SP-003-1


    This product is for sale only in the US, Canada, the UK and EU member countries. At this time, Product does not meet regulatory compliance requirements outside of the aforementioned regions.
    (Specify Model Number)

    What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

    Part Number/Desc.
    Qty
    Description
      
    IS2-THB-B
    SGD1,100.00
    Availability: 1 week
     
    Basic - Environmental Probe Kit
      
    IS2-THB-ST
    SGD1,255.00
    Availability: 4 weeks
     
    Standard - Environmental Probe Kit w/ LCD
      
    IS2-THB-DP
    SGD1,440.00
    Availability: 1 week
     
    Deluxe - Environmental Probe Kit w/ LCD and PoE
      
    IS2-THB-B-CAL-3
    SGD1,570.00
    Availability: 13 weeks
     
    Basic - Environmental Probe Kit (CAL-3)
      
    IS2-THB-ST-CAL-3
    SGD1,795.00
    Availability: 13 weeks
     
    Standard - Environmental Probe Kit w/ LCD (CAL-3)
      
    IS2-THB-DP-CAL-3
    SGD2,055.00
    Availability: 13 weeks
     
    Deluxe - Environmental Probe Kit w/ LCD and PoE (CAL-3)
    Accessories
    RAIL-35-2
    RAIL-35-2
    SGD48.50
    Availability: 1 week
     
    DIN Rail 2m
      
    RAIL-35-1
    SGD25.85
    Availability: 1 week
     
    DIN Rail 1m
      
    PSE-480050US
    Consult Sales  
    Availability: 
     
     
    PoE Injector
      
    DM12CAB-8-1-RA
    SGD59.40
    Availability: 1 week
     
    1m M12 Cable - RA Connector
      
    DM12CAB-8-3-RA
    SGD74.80
    Availability: 1 week
     
    3m M12 Cable - RA Connector
      
    DM12CAB-8-5-RA
    SGD90.20
    Availability: 1 week
     
    5m M12 Cable - RA Connector
      
    DM12CAB-8-1
    SGD59.40
    Availability: 1 week
     
    1m M12 Cable
      
    DM12CAB-8-3
    SGD74.80
    Availability: 1 week
     
    3m M12 Cable
      
    DM12CAB-8-5
    SGD90.20
    Availability: 1 week
     
    5m M12 Cable
      
    SP-003-1
    SGD271.00
    Availability: 1 week
     
    Environmental Smart Probe
      
    SP-003-2
    SGD291.00
    Availability: 1 week
     
    Environmental Smart Probe
      
    SP-004-1
    SGD232.00
    Availability: 1 week
     
    Environmental Smart Probe
      
    SP-004-2
    SGD354.00
    Availability: 1 week
     
    Environmental Smart Probe
      
    SP-004-4
    SGD252.00
    Availability: 1 week
     
    Environmental Smart Probe
      
    SP-005-1
    SGD213.00
    Availability: 1 week
     
    Thermocouple, RTD Smart Probe
      
    SP-010-1
    SGD213.00
    Availability: 1 week
     
    Load Cell Smart Probe
      
    SP-014-1
    SGD223.00
    Availability: 1 week
     
    Process Smart Probe
      
    SP-006-1-C-001G
    SGD535.00
    Availability: 2 weeks
     
    Pressure Smart Probe
      
    SP-006-1-C-050A
    SGD535.00
    Availability: 1 week
     
    Pressure Smart Probe
      
    SP-006-1-C-050G
    SGD535.00
    Availability: 1 week
     
    Pressure Smart Probe
      
    SP-006-1-C-100G
    SGD535.00
    Availability: 1 week
     
    Pressure Smart Probe
      
    SP-006-1-C-250G
    SGD535.00
    Availability: 1 week
     
    Pressure Smart Probe
      
    SP-016-1
    SGD242.00
    Availability: 1 week
     
    Heat Flux and TC Smart Probe
    All prices on this site are shown in Singapore Dollars.

    Product Manuals:

    Download Manual
    Download QuickStartGuide
    We noticed you are from the US. Visit your local site for regional offers and live support.